Recovery Performance Data; R P Data 40F - Patterson-Kelley MACH ‘n’ Roll with NURO Series Installation & Owner's Manual

Condensing indirect domestic & pool water heating system
Table of Contents

Advertisement

7 RECOVERY PERFORMANCE DATA

7.1 P-K MACH 'n' Roll
MACH 'n' Roll Recovery Rates from 40°F
3000
2957
2500
2000
1500
1000
841
500
0
80
90
Choose the curve based on the size of appliance (MnR300, MnR399, MnR500, MnR750, and MnR1050).
Move along the x-axis to the desired domestic hot water supply temperature. Move vertically until the
intersection with the applicable curve. From this intersection, move horizontally to the left to determine
the recovery rate from the y-axis. Several sample recovery rate data points are included for reference.
Revised: January 3, 2020
Released: January 3, 2020
Recovery Performance Data at 40F
1978
1474
550
406
100
110
120
Domestic Supply Temperature (°F)
 Patterson Kelley 2020
All Rights Reserved.
P-K MACH
Technical Service 1.877.728.5351
1148
320
130
140
150
1004905989 MnR & MnRP 300-399-500-750-
1050 NURO Rev C (Jan-2020).docx
®
Gas Fired Appliance
MnR1050
MnR750
MnR500
MnR399
MnR300
953
823
267
230
160
170
180
Page 41