FULLY PUMPED OR GRAVITY SYSTEM

The installer will have set the programmer to suit the installed system. If this is a Fully pumped
system this will allow independent control of Zone 1 and Zone 2, however on a Gravity system Zone 1
and zone 2 are linked so that it is not possible to use Zone 2 independently. This will allow only one
common time setting for both Zone 1 and Zone 2.
The programmer is fitted with a non-rechargeable, long life battery, which will maintain the
programmed time settings for a minimum of ten months with the supply disconnected.
THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT.
During power interruptions the display will be blank, after 3 days the current time of day will be lost.
If the programmer is not to be used for a long period of time, the switch on the rear of the unit
should be returned to the BATTERY OFF position. These are both to prolong the battery life.

SERVICE AND REPAIR

This programmer is NOT user serviceable. Please do not dismantle the unit.
In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of
this user guide located on page 2. If this fails to resolve the problem please contact a local heating
engineer or a qualified electrician.

QUESTIONS AND ANSWERS

The display only reads bAt
Turn the battery on.The switch on the rear of the unit must be in either the Fully
Pumped or Gravity position.
The unit display has become frozen
This could be due to local electrical interference
Using the RESET procedure may rectify the fault.
The indicator neon fails to illuminate on
Using the RESET procedure may rectify the fault. If the problem persists the programmer
Zone 1 or Zone 2
will need replacing.
The indicator neon will illuminate but the
This may indicate a problem elsewhere in your system;
Zone fails to operate
E.g. A zone valve, etc. please contact a registered installer for advice.
There is no display on the
Try the RESET procedure on page 2, if this fails to rectify the problem please have the
programmer
mains supply checked
How do I know if the programmer is still
The ChannelPlus XL range comes with a 5 year guarantee from the date of manufacture.
under warranty
This date is located on the rear of the unit, indicated by a month over a year
How is the programmer removed from
WARNING: The ChannelPlus programmer must only be removed from it's backplate by
the wall
either a qualified electrician or heating engineer; The programmer plugs in to a 9 pin
backplate located on the rear of the unit and is secured using 2 screws located on the
top surface of the unit. Undo these screws and pull forward and down in an arc motion
When setting the programme times, the
This indicates that you have reached an existing set time period, you will be unable to
setting 'bounces' by 10 minute periods
set a new ON/OFF time unless there is an alteration to the existing timed period
Horstmann Controls Limited
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
Page 4

BATTERY

Bristol
BS4 1UP
LEAFLET No P32635
Horstmann's ChannelPlus H27ZXL - Two Channel Programmer
three programmed operating periods per day, seven days a week, with
independent Boost and Advance control on Fully Pumped Systems.
The following are some of the easy to operate features:-
6
9
11
13
15
LCD DISPLAY FEATURES
1 Current TIME OF DAY
2 Day of Week Indicator
3 Switch time SETTING indicator
4 ADVANCE symbol
5 BOOST symbol
6 Current Zone 1 programme
7 Current Zone 2 programme
8 Next Zone 2 switch time
9 Next Zone 1 switch time
ISSUE 3
Flexible 7 Day Control
1 or 2 Hour Boost on each channel
Independent timing on Zone 1 and Zone 2
Advance control gives instant On/Off override
Up to 3 On/Off periods per channel in each 24 Hr operation.
Programme options: Auto / All day / On constantly / Off
3
Internal Slide Switch -
located under front cover
17
16
16 SET slider switch
17 SET Positions
Offers up to
2
1
5 4
7
8
10
12
14
LED INDICATOR
10 Zone 2 ON indicator
11 Zone 1 ON indicator
EASY TO USE PROGRAMME AND FEATURE BUTTONS
12 Zone 2 ADVANCE(ENTER) button
13 Zone 1 ADVANCE (PLUS) button
14 Zone 2 BOOST(COPY) button
15 Zone 1 BOOST (MINUS)button
Both the Zone 1 and Zone 2 SELECT buttons are
located under the front cover
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Channel Plus H27ZXL and is the answer not in the manual?

Questions and answers

Summary of Contents for Horstmann Channel Plus H27ZXL

  • Page 1 2 are linked so that it is not possible to use Zone 2 independently. This will allow only one common time setting for both Zone 1 and Zone 2. BATTERY Horstmann’s ChannelPlus H27ZXL - Two Channel Programmer Offers up to three programmed operating periods per day, seven days a week, with The programmer is fitted with a non-rechargeable, long life battery, which will maintain the independent Boost and Advance control on Fully Pumped Systems.
  • Page 2 RESETTING THE PROGRAMMER SPECIAL FEATURES Electronic equipment can in some circumstances be affected by electrical interference. If the The SET slide switch must be in the PROG.RUN position for the following instructions. programmer’s display becomes frozen or scrambled; or if you wish to revert back to the default time The following actions work independently on either Zone 1 or Zone 2.

Table of Contents