The programmer is fitted with a non-rechargeable, long life battery, which will maintain the
programmed time settings for a minimum of ten months with the supply disconnected.
THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT.
During power interruptions the display will be blank, after 3 days the current time of day will be lost.
These measures are to prolong the battery life.
S S E E R R V V I I C C E E A A N N D D R R E E P P A A I I R R
This programmer is NOT user serviceable. Please do not dismantle the unit.
In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of
this user guide located on page 2. If this fails to resolve the problem please contact a local heating
engineer or a qualified electrician.
Q Q U U E E S S T T I I O O N N S S A A N N D D A A N N S S W W E E R R S S
The unit display has become frozen
This could be due to local electrical interference
Using the RESET procedure may rectify the fault.
The indicator neon fails to illuminate
Using the RESET procedure may rectify the fault. If the problem persists the programmer will
on Hot water or Central heating
need replacing.
channel
The indicator neon will illuminate but
This may indicate a problem elsewhere in your system;
the pump and/or boiler fails to
E.g. A zone valve, etc. please contact a registered installer for advice.
operate
There is no display on the
Try the RESET procedure on page 2, if this fails to rectify the problem please have the mains
programmer
supply checked
How do I know if the programmer is
The CentaurPlus range comes with a 2 year guarantee from the date of manufacture.
still under warranty
This date is located on the rear of the unit, indicated by a month over a year
How is the programmer removed
W W A A R R N N I I N N G G : : The CentaurPlus programmer must only be removed from it's backplate by either
from the wall
a qualified electrician or heating engineer; The programmer plugs in to a 6 pin backplate
located on the rear of the unit and is secured using 2 screws located on the bottom surface
of the unit. Undo these screws and pull forward and up in an arc motion
Horstmann Controls Limited
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
P P a a g g e e 4 4
B B A A T T T T E E R R Y Y
Bristol
BS4 1UP
LEAFLET No P60498
H H o o r r s s t t m m a a n n n n ' ' s s C C 2 2 7 7 - - T T w w o o C C h h a a n n n n e e l l P P r r o o g g r r a a m m m m e e r r Offers up to three
programmed operating periods per day, seven days a week,
with Hot water Boost and Heating Advance control on a fully
pumped system.
T T h h e e f f o o l l l l o o w w i i n n g g a a r r e e s s o o m m e e o o f f t t h h e e e e a a s s y y t t o o o o p p e e r r a a t t e e f f e e a a t t u u r r e e s s : : - -
11
3
9
1.SET indicator
2.Time of day
3.Switch Period symbol
4.SET Button
5.Hot water BOOST or adjust (-) button
6.Central heating ADVANCE or adjust (+) button
7.Hot water (HW) select or ENTER Button
8.Central heating (CH) select or COPY button
ISSUE 4
9.Hot water ON indicator
F F l l e e x x i i b b l l e e 7 7 D D a a y y C C o o n n t t r r o o l l
1 1 H H o o u u r r B B o o o o s s t t o o n n H H o o t t W W a a t t e e r r
I I n n d d e e p p e e n n d d e e n n t t t t i i m m i i n n g g o o n n H H o o t t W W a a t t e e r r a a n n d d H H e e a a t t i i n n g g
C C e e n n t t r r a a l l H H e e a a t t i i n n g g A A d d v v a a n n c c e e g g i i v v e e s s i i n n s s t t a a n n t t O O n n / / O O f f f f o o v v e e r r r r i i d d e e
U U p p t t o o 3 3 O O n n / / O O f f f f p p e e r r i i o o d d s s p p e e r r c c h h a a n n n n e e l l i i n n e e a a c c h h 2 2 4 4 H H r r o o p p e e r r a a t t i i o o n n . .
P P r r o o g g r r a a m m m m e e o o p p t t i i o o n n s s : : A A u u t t o o / / A A l l l l d d a a y y / / 2 2 4 4 H H o o u u r r s s / / O O f f f f
FRONT VIEW OF PROGRAMMER
1
15
16
4
5
10.Central heating ON indicator
11.SET positions
12.PROGRAMME positions
13.BOOST symbol
14.ADVANCE symbol
15.AM/PM symbol
16.Day of week indicator
17.PROGRAMME indicators
2
17
12
13
14
10
6
7
8
P P a a g g e e 1 1

Advertisement

loading

Summary of Contents for Horstmann C27

  • Page 1 10.Central heating ON indicator 2.Time of day 11.SET positions 3.Switch Period symbol 12.PROGRAMME positions 4.SET Button 13.BOOST symbol Horstmann Controls Limited Email: sales@horstmann.co.uk 5.Hot water BOOST or adjust (-) button 14.ADVANCE symbol Bristol Website: www.horstmann.co.uk 6.Central heating ADVANCE or adjust (+) button 15.AM/PM symbol...
  • Page 2 RESETTING THE PROGRAMMER INFORMATION AND ADVICE Electronic equipment can in some circumstances be affected by electrical interference. If the Programming ON/OFF times programmer’s display becomes frozen or scrambled; or if you wish to revert back to the default time If a Heating or Hot water period is not required it can be cancelled by setting the ON and OFF settings please use the following procedure.