Phoenix Contact SD FLASH 2GB AXC EASY SAFE PRO User Manual
Phoenix Contact SD FLASH 2GB AXC EASY SAFE PRO User Manual

Phoenix Contact SD FLASH 2GB AXC EASY SAFE PRO User Manual

Integration and startup of safetybridge and non-safety-related axioline f modules on an axc 1050 controller using the sd card
Table of Contents

Advertisement

Quick Links

Integration and startup of SafetyBridge and
non-safety-related Axioline F modules on an
AXC 1050 controller using the
SD FLASH 2GB AXC EASY SAFE PRO
SD card
User manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SD FLASH 2GB AXC EASY SAFE PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Phoenix Contact SD FLASH 2GB AXC EASY SAFE PRO

  • Page 1 Integration and startup of SafetyBridge and non-safety-related Axioline F modules on an AXC 1050 controller using the SD FLASH 2GB AXC EASY SAFE PRO SD card User manual...
  • Page 2 UM EN SD FLASH 2GB AXC EASY SAFE PRO, Revision 02 2019-09-17 This user manual is valid for: Designation Revision Order No. SD FLASH 2GB AXC EASY SAFE PRO 2403730 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com...
  • Page 3: Table Of Contents

    Startup without SD FLASH 2GB AXC EASY SAFE PRO web interface ..................29 5.1.2 Startup with SD FLASH 2GB AXC EASY SAFE PRO web interface ..30 Validation......................35 SD FLASH 2GB AXC EASY SAFE PRO web interface ............36 Scope of functions without password protection..........37 6.1.1...
  • Page 4 SD FLASH 2GB AXC EASY SAFE PRO 6.1.2 Main view ..................... 39 6.1.3 Project information ................43 6.1.4 External signals ..................45 6.1.5 Overview of module data ..............46 Scope of functions with password protection............49 6.2.1 Communication settings ..............49 6.2.2...
  • Page 5: For Your Safety

    The persons must be able to recognize dangers. Knowledge of the following is also required: – The target system (PROFINET) – The components used in your application – The SAFECONF software used ® – The Microsoft Windows operating system 5 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 6: Field Of Application Of The Product

    1.3.1 Intended use The SD FLASH 2GB AXC EASY SAFE PRO SD card is a licensed memory card for the easy, web-based configuration and startup of a SafetyBridge Technology V3 system. The SD card is intended for operation with an AXC 1050 controller and at least one logic...
  • Page 7: Safety Hotline

    “Axioline F safety module with safe digital out- puts” The documentation for Phoenix Contact devices is available on the Internet at phoenixcontact.net/products. Safety hotline Should you have any technical questions, please contact the Phoenix Contact Safety ho- tline. Phone: +49 5281 9462777 E-mail: safety-service@phoenixcontact.com...
  • Page 8: Description Of The Sd Card

    Description of the SD card General description of the SD card The SD FLASH 2GB AXC EASY SAFE PRO SD card is a licensed memory card which con- tains a preconfigured software application. Operated with a modular small-scale AXC 1050 controller (with extension modules, if nec- essary), the SD card enables easy web-based configuration and startup of your SafetyBridge solution.
  • Page 9: Hardware And Software Requirements

    In order to be able to program and start up the safe system described in this user manual, the following software is required: – Software on the SD FLASH 2GB AXC EASY SAFE PRO SD card – SAFECONF from Phoenix Contact (software for configuring the safety logic and pa- rameterizing the channels), Version 2.92 or later...
  • Page 10: Supported Safetybridge Modules

    SD FLASH 2GB AXC EASY SAFE PRO safe system to the standard external signals of the SAFECONF program in sequence. For example, if you have aligned four digital input modules with eight inputs each, their inputs will be linked one after the other to external signals 0_EI1 to 0_EI32. The same applies to connected digital output modules and external signals 0_EQ1 to 0_EQ32.
  • Page 11: Configuring The Safety Logic In Safeconf

    • Specify the name (“Diag_Visu” in the example in Figure 3-1) and storage location for the project. • Do not use spaces, dashes or special characters. Figure 3-1 Creating the project name and path 11 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 12: Selecting Axl F Lpsdo8/3 1F

    SD FLASH 2GB AXC EASY SAFE PRO Selecting the master de- • Select the logic module SafetyBridge AXL F LPSDO8/3 1F as the master device. vice Figure 3-2 Selecting AXL F LPSDO8/3 1F Selecting a file format • Select “Binary file” as the file format in which the configuration and parameter data re- cord is to be output.
  • Page 13: Island Number

    SafetyBridge island whose project you created in the Proj- ect Wizard. • From the drop-down list, select an island number (1 in the example). Figure 3-6 Selecting an island number 13 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 14: Configuring The Hardware Structure

    SD FLASH 2GB AXC EASY SAFE PRO Specifying a project pass- • Specify a password of at least six characters for access to the project. word Figure 3-7 Specifying a project password Configuring the hardware structure • Configure the hardware structure of the safe system.
  • Page 15: Parameterizing I/O Channels

    In the Hardware Editor, double-click on a terminal point. This opens the window for pa- rameterizing the selected terminal point. • Parameterize the output channels of the logic module SafetyBridge AXL F LPSDO8/3 1F as shown in Figure 3-10. 15 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 16: Parameterization Of Axl F Lpsdo8/3 1F: Output 00, Channel 1/Channel

    SD FLASH 2GB AXC EASY SAFE PRO Figure 3-10 Parameterization of AXL F LPSDO8/3 1F: output 00, channel 1/channel 2 (here: parameterization by double-clicking on the module) Values F_Source_Add and F_Dest_Add are automatically entered. F_Source_Add is de- rived from the island number, while F_Dest_Add is derived from the island and satellite numbers.
  • Page 17 In the event of a change to the watchdog time of a safety module, adjust the total watchdog time of the safe system. • Double-click on the module to set the clock configuration for the channels. Figure 3-12 Automatically entered values and clock configuration 17 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 18: Configuring The Safety Function

    SD FLASH 2GB AXC EASY SAFE PRO Configuring the safety function • Configure the safety function. Drag and drop the desired elements from individual toolbox areas to the connection ed- itor. Various sources are available for safe and standard signals. In the example, the following...
  • Page 19: Inserting Safe Inputs And Outputs From The Hardware Editor

    When you use drag and drop to place the safety module terminal point directly onto a function block input or output, the connecting line is created automatically. Inserting external signals Figure 3-16 Inserting external signals from the “External signals” toolbox 19 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 20: Inserting A Safe Function From The "Safe Functions" Toolbox

    SD FLASH 2GB AXC EASY SAFE PRO Move your mouse over an external signal to display the corresponding tooltip. Figure 3-17 Tooltip Inserting safe functions Figure 3-18 Inserting a safe function from the “Safe Functions” toolbox Inserting comments If required, you can add comments to function blocks and external signals.
  • Page 21: Checking The Project And Creating A Binary File

    Once the check is complete, the amount of program memory used by the program is dis- played. Figure 3-21 Program memory used Creating a *.BIN file If the check is completed without errors, the configuration and parameter data record is cre- ated as a *.BIN binary file. 21 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 22: External Signals

    SD FLASH 2GB AXC EASY SAFE PRO External signals External input and output signals are available in the safe system which are intended for data exchange and communication between the AXC 1050 controller and the logic module SafetyBridge AXL F LPSDO8/3 1F. From the perspective of the safe system, these are al- ways standard input and output signals which can be linked and processed accordingly in SAFECONF.
  • Page 23: External Signals - 32 Bits Of Inputs And 32 Bits Of Outputs

    0_EI1 to 0_EI32. The same applies to connected digital output modules and ex- ternal signals 0_EQ1 to 0_EQ32. You can use a maximum of 32 bits of standard inputs and a maximum of 32 bits of standard outputs in the safe system. 23 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 24: Preparing The Safe System For Startup

    SD FLASH 2GB AXC EASY SAFE PRO Preparing the safe system for startup Before starting up the safe system, complete the following steps: Set the DIP switches of the SafetyBridge modules. Mount the controller, the SafetyBridge modules, and standard Axioline F modules.
  • Page 25: Mounting The Controller, The Safetybridge Modules, And The Standard Axioline F Modules

    “Axioline F: System and installation” user manual and the corresponding user manuals for the devices used. The documents can be downloaded at phoenixcontact.net/products. Please also refer to Section “Documentation” on page 25 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 26: Transferring The *.Bin Binary File To The Controller Sd Card

    Figure 4-2 “Online configuration...” context menu The “Online Configuration” window opens. • From the drop-down list, select the “Phoenix Contact (ILC 1xx, ILC 3xx, RFC 4xx)” en- try. Figure 4-3 Selecting “Phoenix Contact (ILC 1xx, ILC 3xx, RFC 4xx)” 26 / 94...
  • Page 27: Configuration Successful

    4-4), you can view online values in SAFECONF. • Click on the “Show Online Values” button to switch to the online display in SAFECONF. The online values are now displayed in the connection editor. 27 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 28: Startup And Validation

    SD FLASH 2GB AXC EASY SAFE PRO Startup and validation WARNING: Unintentional machine startup – risk of personal injury and/or damage to equipment • Take appropriate measures to ensure that your safe system does not present any danger during startup and validation.
  • Page 29: Startup Without Sd Flash 2Gb Axc Easy Safe Pro Web Interface

    Startup and validation 5.1.1 Startup without SD FLASH 2GB AXC EASY SAFE PRO web interface Startup without web interface is only possible if a type AXL F DI8/1 DO8/1 1H module is connected to the AXC 1050 controller as the first Axioline F module.
  • Page 30: Startup With Sd Flash 2Gb Axc Easy Safe Pro Web Interface

    5.1.2 Startup with SD FLASH 2GB AXC EASY SAFE PRO web in- terface You can access the web interface via a SD FLASH 2GB AXC EASY SAFE PRO web browser. • Switch on the supply voltage of the safe system.
  • Page 31 Click on the “Read the bus again” button (B in Figure 5-2) in order to read in the local bus again. • Click on the “Application config” button to switch to the “Application's configuration” page. 31 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 32: Application's Configuration: New Safety Project Available

    SD FLASH 2GB AXC EASY SAFE PRO Figure 5-3 Application's configuration: new Safety project available If you have already transferred a new configuration and parameter data record (BIN- FILE.BIN file) to the controller via FTP, the “New safety project available” message is dis- played.
  • Page 33: Application's Configuration: "Download Status" Progress Bar

    You can now access the safe system online using the SAFECONF software (see Section “Displaying online values” Section 4.4). • Click on the “Main view” button to switch to the “Main view” page. On the “Main view” page, the SafetyBridge modules in the safe system are displayed. 33 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 34 For additional information on the diagnostic details, please refer to Section “Diagnostics” on page For more detailed information on the SD FLASH 2GB AXC EASY SAFE PRO web inter- face, please refer to Section NOTE: Carry out a validation immediately •...
  • Page 35: Validation

    Depending on the application, systematic errors can lead to hazardous situations. • Verify and validate the SAFECONF program including the connection of all formal pa- rameters. 35 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 36: Sd Flash 2Gb Axc Easy Safe Pro Web Interface

    SD FLASH 2GB AXC EASY SAFE PRO SD FLASH 2GB AXC EASY SAFE PRO web interface The following sections describe the individual pages of the web interface. Figure 6-1 shows the scope of functions of the web interface when accessed with or without password.
  • Page 37: Scope Of Functions Without Password Protection

    Start page Figure 6-2 Start page Product description Description of the scope of functions of the SD FLASH 2GB AXC EASY SAFE PRO soft- ware. Password/login/logout After the password was entered, additional buttons are displayed on the left-hand side of the web interface.
  • Page 38 • “Integration and startup of SafetyBridge and non-safety-related Axioline F modules on an AXC 1050 controller using the SD FLASH 2GB AXC EASY SAFE PRO SD card” user manual available for download. The user manual is available in German and English.
  • Page 39: Main View

    SD FLASH 2GB AXC EASY SAFE PRO web interface 6.1.2 Main view The main view provides an overview of the safe system. All SafetyBridge modules of your safe system are displayed. Standard Axioline F modules are not displayed. Figure 6-3...
  • Page 40 SD FLASH 2GB AXC EASY SAFE PRO Element Indicator Description The safe system is not expecting an acknowledgment. “Acknowledgment re- quest” LED The safe system is expecting an acknowledgment. • Click on the “Acknowledge” button if the “Acknowledgment request” “Acknowledge” button –...
  • Page 41 SD FLASH 2GB AXC EASY SAFE PRO web interface Device overview In the device overview, all SafetyBridge modules of your safe system are displayed. Clicking on a module displays the detailed view of the module (see Section “Overview of module data” on page 46).
  • Page 42 SD FLASH 2GB AXC EASY SAFE PRO Element Indicator Description Code for the diagnostic message Four-digit hexa- Diagnostic code For additional information, please refer to Section “Diagnostics” on decimal value page Plain text Module for which the diagnostic code is displayed...
  • Page 43: Project Information

    SD FLASH 2GB AXC EASY SAFE PRO web interface 6.1.3 Project information Figure 6-5 Project information Binary file data Description of the configuration and parameter data record which was transferred as *.BIN binary file to the controller SD card. LSPDO data Description of the configuration and parameter data record on the logic module SafetyBridge AXL F LPSDO8/3 1F.
  • Page 44: Project Description

    SD FLASH 2GB AXC EASY SAFE PRO Element Description Project description Project description you entered in the SAFECONF software (see Figure 3-4 on page Project name Name of the project you entered in the SAFECONF soft- ware (see Figure 3-1 on page...
  • Page 45: External Signals

    SD FLASH 2GB AXC EASY SAFE PRO web interface 6.1.4 External signals External signals are non-safety-related input and output signals. These signals are available to the non-safety-related Axioline F modules connected in the safe system so that display options can be implemented and status messages can be evaluated, for example.
  • Page 46: Overview Of Module Data

    Module type Name of the SafetyBridge module which indicates the module type and which was specified by Phoenix Contact. Transmission time Current transmission time of the safe module. Indicates the time for the exchange of safe process data.
  • Page 47 SD FLASH 2GB AXC EASY SAFE PRO web interface Element Description Max. TX time Maximum transmission time calculated by the software. F_WD_Time Monitoring time of every SafetyBridge module in the safe system which is involved in the safety function. Diagnostic code Hexadecimal code of the module error that occurred.
  • Page 48 SD FLASH 2GB AXC EASY SAFE PRO Figure 6-8 Detail view for the selected module 48 / 94 PHOENIX CONTACT 107447_en_02...
  • Page 49: Scope Of Functions With Password Protection

    SD FLASH 2GB AXC EASY SAFE PRO web interface Scope of functions with password protection 6.2.1 Communication settings On the “Communication settings” page, you can activate and deactivate the PROFINET and Modbus function of the safe system. You therefore have the option of exchanging data with a higher-level controller using the PROFINET and/or Modbus protocol.
  • Page 50 SD FLASH 2GB AXC EASY SAFE PRO Modbus Element Indicator Description • Click on this button to enable or disable communication via the Mod- “Modbus ON” button – bus protocol (TCP or UDP). “Partner IP Address” • Enter the IP address of the Modbus device with which you wish to...
  • Page 51 SD FLASH 2GB AXC EASY SAFE PRO web interface Element Indicator Description No PROFINET communication errors. “Error” LED Error during PROFINET communication. Code for the diagnostic message Four-digit hexa- Diagnostic code For additional information, please refer to Section “Diagnostics” on...
  • Page 52: E-Mail Settings

    SD FLASH 2GB AXC EASY SAFE PRO Element Indicator Description Diagnostic code Code for the diagnostic message Four-digit hexa- For additional information, please refer to Section “Diagnostics” on decimal value page Add. diagnostic code Additional diagnostic code Four-digit hexa- For additional information, please refer to Section “Diagnostics”...
  • Page 53 SD FLASH 2GB AXC EASY SAFE PRO web interface Outgoing server Element Description “SMTP Server” • Enter the address of the SMTP server. input field “Sender name” • Enter the name of the sender. input field “Password” • Enter the password for accessing your e-mail account.
  • Page 54: Basic Settings

    SD FLASH 2GB AXC EASY SAFE PRO 6.2.2 Basic settings Figure 6-11 Basic settings Local bus Element Indicator Description The LED is displayed after a communication error. After clicking on the “Read the bus again” button, the Axioline F local bus “Bus is being read”...
  • Page 55 SD FLASH 2GB AXC EASY SAFE PRO web interface Element Indicator Description Restarts the Axioline F local bus. “Restart the bus” button – • Click on this button to restart the Axioline F local bus. Reads the Axioline F local bus again.
  • Page 56 SD FLASH 2GB AXC EASY SAFE PRO Element Indicator Description Change the current subnet mask “New Subnet Mask” Plain text input field • Enter the desired subnet mask. Change the current gateway “New Gateway” Plain text input field • Enter the desired gateway.
  • Page 57: Application's Configuration

    SD FLASH 2GB AXC EASY SAFE PRO web interface 6.2.3 Application's configuration The “Application's configuration” page shows whether a new configuration and parameter data record (new *.BIN binary file) exists for the safe system. If a data record exists, you can transfer it to the controller SD card.
  • Page 58 SD FLASH 2GB AXC EASY SAFE PRO Download Element Indicator Description “Island number” input field 1 ... X • Enter the desired SafetyBridge island number. • Enter the file name for the configuration and parameter data record (of the *.BIN binary file).
  • Page 59 SD FLASH 2GB AXC EASY SAFE PRO web interface Save data Element Description • Enter a file name with the extension “.csv”. • Click on “Save data”. The following data is stored in the file specified in the input “File name for download field: and activation”...
  • Page 60: Ordering Data

    SD FLASH 2GB AXC EASY SAFE PRO Ordering data Hardware and software Description Type Order No. Pcs./Pkt. Program and configuration memory, pluggable, 2 GB, with SD FLASH 2GB AXC EASY S 2403730 license key and application program for easy web-based...
  • Page 61 Axioline F, digital in/output, digital inputs: 16, 24 V DC, AXL F DI16/1 DO8/2-2A 2H 2702291 1-conductor, digital outputs: 8, 24 V DC, 2 A, 2-conductor, transmission speed on local bus: 100 Mbps, IP20 protection, including bus base module and Axioline F connectors 61 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 62: Documentation

    SD FLASH 2GB AXC EASY SAFE PRO Documentation Description Type Order No. Pcs./Pkt. User manual: UM EN AXC 1050 (XC) – “Installing and operating the AXC 1050 and AXC 1050 XC controllers” User manual: UM EN AXL F SYS INST –...
  • Page 63: A Technical Appendix

    “Communication OK” LED: green System running continuously. Depending on the application, LED page Function block messages: 13 (output 4) may flash or light up continuously. “SBT logic is running” LED: green Figure A-1 Flow chart 63 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 64: A 2 Functions Of The Inputs And Outputs Of The Axioline F Module Axl F Di8/1 Do8/1 1H

    SD FLASH 2GB AXC EASY SAFE PRO Functions of the inputs and outputs of the Axioline F module AXL F DI8/1 DO8/1 1H Inputs Table A-1 Inputs Input Function The current Axioline F local bus is read again. The default IP address settings are assigned to the AXC 1050 controller.
  • Page 65: A 3 Exchange Variables

    EI24 External input signal AppAck EI25 External input signal AppAck EI26 External input signal AppAck EI27 External input signal AppAck EI28 External input signal AppAck EI29 External input signal AppAck EI30 External input signal 65 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 66 SD FLASH 2GB AXC EASY SAFE PRO Table A-3 Output data from the perspective of the PLC PROFINET Modbus address SafetyBridge SAFECONF SAFECONF address process data, input Process data, Process data, Assignment Assignment Description Note output output Byte Word AppAck...
  • Page 67: Safetybridge

    Error acknowledgment of AckLPSDO LPSDO the LPSDO Acknowledge Error acknowledgment of AckDev1 device 1 satellite 1 Acknowledge Error acknowledgment of AckDev2 device 2 satellite 2 Acknowledge Error acknowledgment of AckDev3 device 3 satellite 3 67 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 68 SD FLASH 2GB AXC EASY SAFE PRO Table A-3 Output data from the perspective of the PLC PROFINET Modbus address SafetyBridge SAFECONF SAFECONF address process data, input Process data, Process data, Assignment Assignment Description Note output output Byte Word Acknowledge...
  • Page 69 Description Note output output Byte Word Not used Not used Not used Not used Not used Not used Not used Not used Not used Not used Abbreviations: LPSDO AXL F LPSDO8/3 1F SafetyBridge technology 69 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 70: Input Data From The Perspective Of The Plc

    SD FLASH 2GB AXC EASY SAFE PRO A 3.2 Input data from the perspective of the PLC Table A-4 Input data from the perspective of the PLC PROFINET Modbus address SafetyBridge SAFECONF SAFECONF address process data, output Process data, Process data,...
  • Page 71 AppDiag EQ26 output signal External AppDiag EQ27 output signal External AppDiag EQ28 output signal External AppDiag EQ29 output signal External AppDiag EQ30 output signal External AppDiag EQ31 output signal External AppDiag EQ32 output signal 71 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 72 SD FLASH 2GB AXC EASY SAFE PRO Table A-4 Input data from the perspective of the PLC PROFINET Modbus address SafetyBridge SAFECONF SAFECONF address process data, output Process data, Process data, Assignment Assignment Description Note input input Byte Word Status of LPSDO,...
  • Page 73 If satellites 2 ... 16 9 ... 38 4 ... 18 InData2 ... 16 2 ... 16, inputs are used as an 00 ... 03(07) SSDI! wDiagCodeLPSDO LPSDO diagnostic code Diagnostic code of wDiagCodeDev1 satellite 1 73 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 74 SD FLASH 2GB AXC EASY SAFE PRO Table A-4 Input data from the perspective of the PLC PROFINET Modbus address SafetyBridge SAFECONF SAFECONF address process data, output Process data, Process data, Assignment Assignment Description Note input input Byte Word Diagnostic code of...
  • Page 75 Status of satellite 1, FeedBackData1 output 02, channel 2 Status of satellite 1, FeedBackData1 output 03, channel 1 Status of satellite 1, FeedBackData1 output 03, channel 2 Not used Not used Not used Not used Not used 75 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 76 SD FLASH 2GB AXC EASY SAFE PRO Table A-4 Input data from the perspective of the PLC PROFINET Modbus address SafetyBridge SAFECONF SAFECONF address process data, output Process data, Process data, Assignment Assignment Description Note input input Byte Word Not used...
  • Page 77: Safety Function

    Acknowledgement by OPAckReq operator requested Reset in the ResetRequest safety program requested Safety function in the SafetyDemand safety program requested Not used Not used Not used Not used Not used Not used Not used 77 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 78 SD FLASH 2GB AXC EASY SAFE PRO Abbreviations: LPSDO AXL F LPSDO8/3 1F SSDI AXL F SSDI8/4 1F SSDO AXL F SSDO8/3 1F SafetyBridge technology 78 / 94 PHOENIX CONTACT 107447_en_02...
  • Page 79: A 4 Diagnostics

    At least one of the modules used does not correspond to the approved hardware. “x” indicates the slot for the module. x090 – The Axioline F local bus has not been read. 8000 – The Axioline F local bus is running without errors. 79 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 80 SD FLASH 2GB AXC EASY SAFE PRO A 4.2 Modbus diagnostic codes Table A-6 Modbus diagnostic code DiagCode AddDiagCode Description [hex] [hex] 0000 The block is not active. 8000 The block is active. C010 Incorrect block parameterization. 0010 An invalid value has been specified at the RegOffsetIn- puts parameter (>...
  • Page 81: Ip Address Errors

    Another block instance is already using this connection. A 4.3 IP address errors Table A-7 IP address errors DiagCode Description [hex] x010 IP address could not be set/changed. x020 IP address could not be read. 81 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 82: Profinet Diagnostic Codes

    SD FLASH 2GB AXC EASY SAFE PRO A 4.4 PROFINET diagnostic codes Table A-8 PROFINET diagnostic codes DiagCode AddDiagCode Description [hex] [hex] 8000 function block in normal operating mode xxxx currently active step of state machine C100 unexpected response code of cpu control...
  • Page 83: E-Mail Function Diagnostic Codes

    01C2 Requested e-mail action not executed: mailbox cannot be reached (e.g., mailbox is active) 01C3 Requested action aborted: local error during processing. 83 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 84 SD FLASH 2GB AXC EASY SAFE PRO Table A-9 Errors for e-mail functions DiagCode AddDiagCode Description [hex] [hex] 01C4 Requested action not executed: insufficient system memory. 01F4 Syntax error, command not recognized. (This also in- cludes the error where a command line is too long.) 01F5 Syntax error in parameters or arguments.
  • Page 85: A 5 Safetybridge Transmission Times Depending On The Number Of Modules

    16 DI / 16 DO 56 ms AXL F LPSDO8/3 1F + 16 satellites 16 DI / 16 DO 75 ms * All time values are approximate values and might differ. Abbreviations: Digital input modules Digital output modules 85 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 86: B Appendix For Document Lists

    DIP switches of the logic module SafetyBridge AXL F LPSDO8/3 1F ................24 Figure 4-2: “Online configuration...” context menu ..........26 Figure 4-3: Selecting “Phoenix Contact (ILC 1xx, ILC 3xx, RFC 4xx)” ....26 86 / 94 PHOENIX CONTACT 107447_en_02...
  • Page 87 Communication settings ..............49 Figure 6-10: E-mail settings ..................52 Figure 6-11: Basic settings ..................54 Figure 6-12: Application's configuration – New Safety project available ....57 Appendix A Figure A-1: Flow chart ................... 63 87 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 88: B 2 List Of Tables

    SD FLASH 2GB AXC EASY SAFE PRO List of tables Section 2 Table 2-1: Minimum hardware configuration............9 Table 2-2: Supported SafetyBridge modules............10 Section 3 Table 3-1: External signals – 32 bits of inputs and 32 bits of outputs ....23...
  • Page 89: B 3 Index

    SD card Axioline F............... 10 Inserting ..............25 SafetyBridge............10 Startup ................ 28 External signals............22 Validation ..............35 Flow chart ..............63 Hardware configuration..........9 Maximum configuration..........9 Minimum configuration..........9 Mounting ..............25 89 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 90 SD FLASH 2GB AXC EASY SAFE PRO Web interface Communication settings ........49 E-mail settings............52 External signals ............. 45 Main view .............. 39 Overview of module data........46 Project information ..........43 Start page.............. 37 90 / 94 PHOENIX CONTACT...
  • Page 91: C Revision History

    Line 6 removed from table Appendix A Line 3 in Table A-1 revised Appendix C Table title deleted 2019-09-17 Revised: – Editorial revision Appendix A Table A-3 Table A-4 altered Section A 5 added 91 / 94 107447_en_02 PHOENIX CONTACT...
  • Page 92 SD FLASH 2GB AXC EASY SAFE PRO 92 / 94 PHOENIX CONTACT 107447_en_02...
  • Page 93 The receipt of technical documentation (in particular user documentation) does not constitute any further duty on the part of Phoenix Contact to furnish information on modifications to products and/or technical documentation. You are responsible to verify the suitability and intended use of the products in your specific application, in particular with regard to observing the applicable standards and regulations.
  • Page 94 Should you have any suggestions or recommendations for improvement of the contents and layout of our manuals, please send your comments to: tecdoc@phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany 94 / 94 phoenixcontact.com...
  • Page 96 PHOENIX CONTACT GmbH & Co. KG Flachsmarktstraße 8 32825 Blomberg, Germany Phone: +49 5235 3-00 Fax: +49 5235 3-41200 E-mail: info@phoenixcontact.com phoenixcontact.com...

Table of Contents