1. Overview
TC series parcel scale can be used widely in a variety of purposes of weighing measurement, its
excellent performance may be satisfied with all the request from the client.
1.1 High precision, hypersensitivity and fast reaction time.
1.2 Using high precision single point load cell, to overcome the general high-precision
2. Specifications and Performance indexes
Model
Weighing (max.)
Resolution
Calibration graduation
Calibrating weight
Dimension of platform
Power supply
Temperature
Humidity
scales
TC8KP
TC15KP
8kg
15kg
0.2g
0.5g
10d
10d
5kg
10kg
218×300mm
Power adapter AC220V±10% 50Hz±1Hz DC6V/300mA
TC30KP
TC30KL
30kg
30kg
1g
1g
10d
10d
20kg
20kg
Or Battery 4×AAA
0-40℃
≤80%R.H
TC60KL
TC120KL
60kg
120kg
5g
10g
10d
10d
50kg
100kg
320×380mm

Advertisement

loading

Summary of Contents for G&G TC-KP Series

  • Page 1 Operating Manual for TC-KP and TC-KL scales 1. Overview TC series parcel scale can be used widely in a variety of purposes of weighing measurement, its excellent performance may be satisfied with all the request from the client. 1.1 High precision, hypersensitivity and fast reaction time. 1.2 Using high precision single point load cell, to overcome the general high-precision 2.
  • Page 2 3. Shape and Installation TC-KP: 1. brand 2. battery symbol 3. on/off switch 4. Unit 5. count 6. light 7. tare 8. data line 9. signal input interface 10. power socket 11. signal output interface 12. Level adjust 13. scale pan TC-KL: 1.
  • Page 3 4. Operation manual 1. Before using the scale, place it on a stable platform and adjust its feet to make the scale level, and 15 minutes power on before using. 2. key function: 2.1 “ON / OFF” key: hold on “ON/OFF” key until the display shows “ON”, then displays the at last, displays from “F----1”...
  • Page 4: Display Information

    5. Setting and meaning When the scale is off, press and hold“UNIT”, then press the “ON/OFF”. The scale will now start in the setting mode. Pressing “UNIT” can change the parameters; pressing “TARE” can change the values of parameter. C1----2 Sensitivity setting 0 1 2 3 4, the larger number is, the less sensible but the better stable. C2----1 Filtering strength setting 0 1 2 3, the larger number is, the lower reaction speed but the better stable.
  • Page 5 8. Display information Problems Possible causes Measure to take Display shows nothing 1.The ON/OFF switch is defect 1.The ON/OFF switch 2.internal circuit is defect must be changed 3. batteries are empty 2. Return to the factory 4. A/D switch is defect to repair 3.