August 2018
Bake and Broil operations shut down when temperature reaches
approximately 250F.
If the selected bake or broil function operates briefly, then shuts down, the problem is not likely
with the ERC. A problem may exist with the cooling blower motor or the motor wiring.
Models affected:
C2S995SEL, PGS960BEL, PGS960EEL, PGS960FEL, PGS960SEL,
CGS995EEL, CGS995SEL
Serial numbers:
Repair Procedure:
1.
Cycle power to range. Press and hold '2' and 'Bake' simultaneously for three seconds to
enter Fault Retrieval Mode. Press '1' to display stored faults. Fault code F350 or F352
will likely be displayed. This indicates the ERC has detected that the cooling fan blower
wheel is not turning, or turning too slowly.
2.
Enter the ERC's Test Mode by pressing and holding '1' and 'Bake' for three seconds.
Pulse the cooling blower at low speed by pressing '3'. If blower wheel, which is visible
through the vent trim at rear of maintop, fails to turn, service is required.
3.
DISCONNECT POWER. (LOTO) Remove:
Grates and top burners
Rear spacer-to-wall trim
RJ45 connector from square hole
in upper corner of rear wire cover
with a flat screwdriver
Backguard complement strip and
upper rear wire cover
Vent trim
Maintop
Fan motor spill guard to access the motor's electrical connections (see picture
above)
All
Front Control Gas Ranges
1
TB17-18
continued...

Advertisement

loading

Summary of Contents for GE C2S995SEL

  • Page 1 If the selected bake or broil function operates briefly, then shuts down, the problem is not likely with the ERC. A problem may exist with the cooling blower motor or the motor wiring. Models affected: C2S995SEL, PGS960BEL, PGS960EEL, PGS960FEL, PGS960SEL, CGS995EEL, CGS995SEL Serial numbers: Repair Procedure: Cycle power to range.
  • Page 2 4. Check for foreign objects in the blower wheel. The wheel should rotate freely by hand without noise or undue friction. Be sure nothing is pressing against the red hub on the end opposite the motor. Re-route any wires, such as the RJ45 connector leads, that may lie in contact with the motor shaft.
  • Page 3 7. Press ‘3’ again and, if still no operation, check for line voltage between the low speed (black wire) and neutral tabs. Also check for line voltage at the ERC between J903 pin 1 and neutral. If line voltage is not present, DISCONNECT POWER and replace the MACHINE BOARD WITH FRAME.
  • Page 4 11. Transfer the sensor circuit board from the defective blower to the replacement blower. Connect the sensor circuit board and connect wire terminals to motor tabs. Carefully work blower assembly into place and attach to duct by replacing the hex-head screws in the order indicated in the photo above.