Download Print this page

Yale UNI Series Installation Instructions

Advertisement

Quick Links

The closing force for these series door
closers is adjustable from a size 1 to a size 6,
as outlined in ANSI Standard A156.4. When
these series of door closers are installed and
adjusted to conform to ADA reduced opening
force requirements (5 lbs max.) for interior
doors, they may not have adequate closing
force to reliably close and latch the door. Power adjustments
charted on Page 4 are recommended where possible, to
ensure proper door control.
!
Always use template covering door-opening-angle desired,
correct door-thickness and frame-reveal, and door-hanging-
hardware being used. Template dimensions in these
instructions (page 2) cover frame reveals to 7-3/8" (187mm)
in opening with 1-3/4" (44mm) thick doors hung on 4-1/2"
(114mm) wide template-hinges (figure 2), 3/4" (19mm)
offset-pivots (figure 2) or center-pivots (figure 3).
!
Check hand of door: right or left (see figure 5, page 3). Make
sure that door opens the full angle desired and latches
without any binding action or interference. Note that hold-
open units will require that door swing five (5) degrees past
hold-open point, to dead-stop position.
!
It is suggested that sex-nuts and bolts be used to mount
arm-foot and to mount closer to flush partitions.
!
Top Jamb Unitrols are supplied with arm rod units according
to frame-reveal. An arm number is stamped on the arm
rods, as shown on Figures 2 and 3 (page 2).
Components:
Power
Adjustment
Shaft
3500 Series
Standard Plastic
with Cover Screws
Cover with Insert
Installation Instructions
Non Hold Open
UNI TJ3300
UNI TJ3301
Series No.*
UNI TJ3500
UNI TJ3501
* These series have a DELAYED ACTION CLOSING option available that
is identified with a "DL" suffix to the series number.
damage or personal injury. These instructions
Optional
3300 Series Standard
Full Metal Cover
Narrow Plastic Cover
3500M Series
80-9303-2214-010 (07-08)
Hold Open
UNI TJ3310
UNI TJ3311
UNI TJ3510
UNI TJ3511
CAUTION
An incorrectly installed or improperly
adjusted door closer can cause property
should be followed to avoid the possibility
of misapplication or misadjustment.
Power Adjustment Chart for TJ3301/TJ3501, TJ3311/TJ3511 ONLY
DOOR
Interior
Door
Exterior
Door
NOTE: Maximum of 20 turns (360°) of Power Adjustment Shaft.
Closer is shipped set at 10 turns.
2 Sex-nuts
Holder Control
w/ 1639 Pinion Cap
UNI Stop/Holder
Sizing
2, 3, 4, 5 or 6
Multi-Size 1 thru 6
2, 3, 4, 5 or 6
Multi-Size 1 thru 6
Power Adjust
+
Use 5/16" Socket or Adjustable Wrench
for this Adjustment
-
Number of Turns Required
MAXIMUM DOOR SIZE
32"
(0.85M)
(0.90M)
4
7
Rod Unit
(Arm Number Stamp)
Main Arm
Screw
Rod Screws
Slide unit
Optional Architectural
Metal Cover
3500MA Series
36"
42"
48"
(1.00M)
(1.20M)
7
8
9
8
12
10
Optional
Thru-Bolt
&
Grommet Nuts
Optional
Architectural Plastic
Full Cover w/ Insert
3500A Series

Advertisement

loading

Summary of Contents for Yale UNI Series

  • Page 1 Installation Instructions UNI Stop/Holder 80-9303-2214-010 (07-08) Non Hold Open Hold Open Sizing UNI TJ3300 UNI TJ3310 2, 3, 4, 5 or 6 UNI TJ3301 UNI TJ3311 Multi-Size 1 thru 6 Series No.* UNI TJ3500 UNI TJ3510 2, 3, 4, 5 or 6 UNI TJ3501 UNI TJ3511 Multi-Size 1 thru 6...
  • Page 2 Top-Jamb Installation Template Figure 1 4 Holes For Drop Plate Application Only C L Closer Pinion (304.8) 5/16 (102) (102) (25) (19.1) (13) Reveal 3-1/4 4-1/8 (82.6) (104.8) 1-1/8 Without Drop Plate * Frame Rabbet (29) Frame Stop With Drop Plate * (76) C L Hinge or Pivot * Always use frame or transom rabbet as...
  • Page 3 Installation Sequence • Set average-power of multi-size closer. (Series UNI • Mount drop plate, (if used) and closer. Closer power TJ3301, UNI TJ3501 ONLY) See Power Adjust chart adjustment shaft toward lock edge. on Page 1. • Disassemble rod-unit from arm-assembly and install •...
  • Page 4 Yale ® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Tel: (800)-438-1951 • Fax: (800)-338-0965 Copyright © 2005, 2008, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. www.yalecommercial.com Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

This manual is also suitable for: