Chapter 1 Product introduction Table of Contents Overview ....................1-4 1.1.1 High performance wireless technology ............1-4 1.1.2 Good reliability and design optimization ............. 1-5 1.1.3 Robust design for industrial hardware............1-5 1.1.4 Product profile and dimensions ..............1-5 LED indicator ....................1-6 Installation ....................
Page 2
Disclaimers and Limitation of Liabilities To the maximum extent permitted by law and regardless DELTA be aware or has been advised of the possibility of these damages, DELTA is not liable to any user or anyone else for: (a) any loss of use, data, reputation, goodwill, credit, opportunity, economy or profits, whether or not foreseeable;...
Page 3
Ch ap te r 1 Prod uc t in tr od uc tion claim or in connection with the use of or access to the Software or Services. Warning 此设备应安装在限制进出的场所。限制进出场所指仅能透过特殊工具、锁和钥匙或 其他安全手段才能进出的场所。 This equipment should be installed in a place where access is restricted. Restricted places are places that can only be accessed through special tools, locks and keys or other security means.
De lta In dus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 1.1 Overview Delta’s industrial wireless DVW-W01I2-E1 series features Ethernet port, RS-232 and RS-485, supports standard MODBUS protocol for executing and controlling data transmission with operating devices.
Ch ap te r 1 Prod uc t in tr od uc tion 1.1.2 Good reliability and design optimization Redundant dual DC power input One set of digital input (DI) One set of alarm output (DO) 1.1.3 Robust design for industrial hardware ...
De lta In dus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description LED indicator Antenna socket Signal strength Ethernet port RS-485 port RS-232 port Power terminal Reset button 1.2 LED indicator Color Status Description...
De lta In dus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 1.3.3 Wiring the redundant power input The DVW-W01I2-E1 is equipped with one to two sets of DC input (PWR1 / PWR2). Both sets of DC input can be connected to a wide range of power sources (12 to 48VDC).
Ch ap te r 1 Prod uc t in tr od uc tion 1.3.5 Wiring the digital input The DVW-W01I2-E1 is equipped with one to two sets of digital input. When input voltage is between 0 to 5V, the state of DI is OFF; input voltage between 11 to 30V, the state of DI is ON. The maximum input current is 6mA.
De lta In dus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 1.3.6 Pin definition RS-232 & RS485 Pin no. RS-232 Pin no. RS-485 Ethernet port (RJ45) & power input Ethernet port (RJ45) Power input Interface...
(120 ohm) C T S C T S G ND 1.4 Package checklist The package contains the following accessories: Delta industrial wireless DVW-W01I2-E1 series x1 Instruction sheet x1 SMA antenna x 2 Wall mount metal accessory x1 ...
Page 12
Chapter 2 User Interface Table of Contents Chapter 2 User Interface ..................... 2-1 2.1 Configuration ........................2-2 2.2 Connection and access settings ..................2-2 2.3 General configurations ..................... 2-4 2.3.1 AP mode setup ......................2-4 2.3.2 Client mode setup ....................2-6 2 - 1...
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 2.1 Configuration Before using DVW-W01I02-E1 series, please pay attention to the following item preparation. Item Description Contains Windows operating system and web browsers. Power supply Supports 12-48V with output power larger than 2.5W.
Page 14
Ch ap te r 2 User In ter fac e Manually configure the local IP address. Since the default IP address is 192.168.1.5 for router settings, the subnet masks is 255.255.255.0, therefore, the local IP on PC can be set anywhere between 192.168.1.1 to 254 excluding 192.168.1.5 and with no repeating IPs.
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 3. Open browser (e.g. IE) then type in default IP address 192.168.1.5 and click enter. The following log-in page appears for users to enter the correct username and password (Default setting: admin/password). 2.3 General configurations 2.3.1 AP mode setup...
Page 16
Ch ap te r 2 User In ter fac e From WLAN2.4G listed on the menu, select Operation Mode, choose AP mode and click Apply. 4. Select Basic Configuration and setup SSID name as well as WPA2-PSK for security mode (recommended), then click Apply.
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 2.3.2 Client mode setup When users have two DVW devices, one uses AP mode and the other as client mode, both are combined via wireless connection.
Page 18
Ch ap te r 2 User In ter fac e 4. From WLAN2.4G listed on the menu, select Operation Mode, choose Client mode and click Apply. 5. Select Basic Configuration and click “Site Survey”. 6. Select the configured AP SSID (e.g. SlimWiFi_4456). When SSID cannot be found, please click “Refresh”.
Page 19
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 7. Type in the password for AP setting and click APPly to complete Client and AP connection. 8. When connection is complete, select Ping under Maintenance. Then, type in destination IP to test the connection.
Page 20
Chapter 3 Function Guide Table of Contents System ....................... 3-2 3.1.1 System configuration ................. 3-2 3.1.2 System CPU status ..................3-2 Basic configuration ..................3-3 3.2.1 System information ................... 3-3 3.2.2 Network configuration ................
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 3.1 System The main display focuses on DVW-W01I2-E1 series present system information and CPU status. 3.1.1 System configuration Displays information which can be categorized into three parts: System Configuration, Device Info and 802.11 Info.
Users can define the device name DVW-W01I2-E1 Device location Users can define the device location Europe Device description Delta Dual-Band Users can provide detailed device description WiFi Router Device contact information Users can input contact information of maintenance personnel. NONE...
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 3.2.2 Network configuration Network configuration allows users to setup IP, IP address, IP subnet mask, gateway IP and primary DNS. There are several IP modes available for network configuration.
Ch ap te r 3 Fu nc tion G uide Description Default value Configure IP address and identify DVW-W01I2-E1 series in TCP/IP 192.168.1.5 network. IP subnet mask Set the IP subnet mask of router LAN ports. (Example: 255.0.0.0 is Type A address; 255.255.0.0 is Type B address; 255.255.255.0 is 255.255.255.0 Type C adderss) Gateway IP...
Page 25
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Attention For RS-232 and RS-485, the configured map ID range cannot have repeated regions, because the system forwards the request to serial ports base on the network port of the map ID in the request data.
Page 27
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description Default value Operation mode Select the roles and operating agreement for present network and serial ports via following options: MODBUS ASCII Slave: The network port for DVW device operates in MODBUS TCP Server mode, the RS-485 serial port operates in MODBUS ASCII master mode.
Page 28
Ch ap te r 3 Fu nc tion G uide Description Default value Configuring stop bit for serial port. Optional values include 1 or 2. Baud rate Configuring baud rate for serial port. Optional values include 2400, 9600 4800, 9600, 19200, 38400, 57600, 115200. Station ID Displays the station ID of the device.
Page 29
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l For instance, RS-232 serial port slave ID setting range is 1-20, map ID setting range 1-20; while RS-485 serial port slave ID setting range is 1-20 and map ID setting range is 21-40.
Page 30
Ch ap te r 3 Fu nc tion G uide Description Default value Operation mode Select the roles and operating agreement for present network and serial ports via following options: 1. MODBUS ASCII Slave: The network port for DVW device operates in MODBUS Close TCP Server mode, the RS-485 serial port operates in MODBUS ASCII master mode.
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description Default value 2. MODBUS RTU Slave: The network port for DVW device operates in MODBUS TCP Server mode, the RS-485 serial port operates in MODBUS RTU master mode.
Page 32
Ch ap te r 3 Fu nc tion G uide 3.3.2.1 RS-485 In this mode, the DVW series is used as client’s serial server of communication via TCP/UDP protocol which can transmit RS-485 data to the serial server. 3 - 1 3...
Page 33
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description Default value Operation mode Select the current operating serial port default to “Close”, other options include: 1. TCP mode: serve as client’s serial server of communication via TCP protocol. Close 2.
Page 34
Ch ap te r 3 Fu nc tion G uide Description Default value 1~99: When idle time reaches setting value, TCP connection is closed. Destination IP and port Set connected serial server IP range and port, the IPand port cannot have the same configuration. Max. 4 serial servers for None simultaneous connection.
Page 35
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 3 - 1 6...
Page 36
Ch ap te r 3 Fu nc tion G uide Description Default value Operation mode Select the present operating serial port default to “Close”, other options include: 1. TCP mode: serve as client’s serial server of communication via TCP protocol. Close 2.
Page 37
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description Default value Flow Control Set types of flow control. Optional values include “XON/XOFF”, None “RTS/CTS”. TCP keepalive time Configure idle time of TCP to auto-close TCP connection.
Ch ap te r 3 Fu nc tion G uide Description Default value Operation mode Select present operating serial port mode from the following options: 1. TCP server: as TCP server, create connection once receive client host request Close then client host and DVW device can start data transmission. 2.
Page 39
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description Default value Operation mode Select present operating serial port mode from the following options: 1. TCP server: as TCP server, create connection once receive client host request Close then client host and DVW device can start data transmission.
Ch ap te r 3 Fu nc tion G uide 3.3.4 MODBUS cache table Since the transmission speed of Ethernet interface is faster than that of serial ports, therefore, when Ethernet devices send requests to serial devices, more time is required for waiting serial port data. MODBUS cache table provides PLCs with relevant configuration information (e.g.
Page 41
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Explanation Default value Add a configuration message (up to 100 messages). Edit Edit selected configuration messages. Delete Delete assigned configuration messages. Online When clicked, real-time values gathered for relevant addresses are shown on the right section of the page.
Page 42
Ch ap te r 3 Fu nc tion G uide Explanation Default value Set format to Hex, Dec, Bin (hexadecimal, decimal, binary). When add or edit coil device types, format is not required. Online Set or not to set data display on MODBUS monitoring table. Not checked 3.3.4.2 RS-232 cache table...
Page 43
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Explanation Default value Displays the available data size for monitoing. Timeout calibration Calibrate the response timeout. When users click Detect, the DVW device will use the MODBUS cache table for communication.
Ch ap te r 3 Fu nc tion G uide Explanation Default value Starting from MODBUS address and connecting to monitored data None size. Format Set format to Hex, Dec, Bin (hexadecimal, decimal, binary). When add or edit coil device types, format is not required. Online Set or not to set data display on MODBUS monitoring table.
Page 45
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 3.4.2.1 Basic configuration The setting corresponds to operation mode. Different operation mode will have different basic configurations. AP mode: In AP mode, users can add or edit WLAN basic configurations.
Page 46
Ch ap te r 3 Fu nc tion G uide Description Deault value After selecting this option, multimedia data is given priority during Check data transmission. Client isolation After selecting this option, clients connected to this AP cannot Uncheck access each other. Security mode Set AP operation security mode from the following options: ...
Page 47
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description Default value EXTAP Enabled: When EXTAP is enabled, client compatibility increases along with more compatible AP. Disabled ...
Page 48
Ch ap te r 3 Fu nc tion G uide Description Default value channel.Setting range: 10~200ms. Scan period 1000 Set the AP interval period for DVW scan. Setting range: 1000~300000ms。 Scan threshold Set the AP threshold once DVW is triggered for scanning, but only when the AP’s transmission power connected to the present DVW is lower than the threshold value, the DVW will scan the available AP based on the scan period.
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description Default value Password phrase requires 8 to 63 ASCII characters or 64 None hexadecimal digit. 3.4.2.3 Advanced configuration The configuration provides users to execute advanced parameter settings based on different on-site wireless environment.
Ch ap te r 3 Fu nc tion G uide Description Default value To enable or disable wireless function. Enabled Operation mode Set wireless operation mode: AP mode: used as an intermediate point for wired and wireless devices connection, data transmission and more. ...
Page 51
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description Default value Operation mode Display present operation mode RF type Select from the following types: AC/N Mixed: only supports mixed mode IEEE 802.11ac/n ...
Page 52
Ch ap te r 3 Fu nc tion G uide Description Default value EXTAP Enabled: When EXTAP is enabled, client compatibility increases along with more compatible AP. Disabled Disabled: When EXTAP is disabled, recommend using the AP of DVW-W01I2-E1 for enhanced connection.
Page 53
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l Description Default value Client Mode To enable or not enable fast roaming function. Disabled Scan channel Set DVW scan strategy, the system offers two options. ...
Ch ap te r 3 Fu nc tion G uide Description Default value Roaming threshold Set DVW roaming threshold which is a condition for DVW to execute switch action. When the present AP’s transmission power in connection with DVW is lower than the setting value, the DVW can switch to new AP. Setting range: -95~0 dBm.
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 3.7 Maintenance 3.7.1 Session timeout Users can set session timeout but when the setting time is exceeded, it will auto log off the system and a message regarding the action is presented to users.
Ch ap te r 3 Fu nc tion G uide Description Default value Old password The current admin. password New password Set new admin. password Repeat new password Repeat the new password 3.7.3 System log backup The function allows documents derived from the logs to be stored in PCs or storage devices. 3.7.4 Roaming log Roaming log function can record the device as WIFI station that quickly swich from one AP message to...
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 3.7.5 Serial log From selecting a serial, users can determine the assigned log level and serial logs. The image above shows the system can derive all log level as “Error” from RS232 serial logger. Users can click Backup button and download the logs in PCs.
Ch ap te r 3 Fu nc tion G uide 3.7.8 Firmware upgrade DVW-W01I2-E1 releases new upgraded firmware regularly to enhance product performance and include more functions. We strongly recommend users to do regular checkup and proceed firmware upgrade for your DVW-W01I2-E1 device.
De lta Indus tr ia l W ire less D VW-W0 1 I2- E1 Ser ies Us er Man ua l 3.7.11 Log off Users can click Log off to exist the configuration page. When configuration and operating on the DVW-W01I2-E1 device is complete, we recommend to log off from your current account for security consideration.