Checking the Contents

Before beginning the installation, verify that all components required for the installation, as listed in
the packing list document attached to the box, is at hand. If you are missing any of the components,
contact Radware Technical Support.

Mounting the Platform

The platform can be either rack-mounted or mounted on a tabletop. The package includes brackets
to enable rack-mounting of the platform. Rubber feet are attached to the bottom of the platform to
enable tabletop mounting.
Note:
After you mount the platform, ensure that there is adequate airflow surrounding it.
To rack-mount the platform
1. Attach one bracket to each side of the platform, using the screws provided.
2. Attach the platform to the rack with the mounting screws.
3. Connect at least one ground wire from the platform chassis to the rack. Typically, the platform
has one or two, special, ground screws on the back panel near the screws that secure the power
supply.
Warning:
Reliable grounding of rack-mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the branch circuit (for
example, use of power strips). The rack must be properly grounded.
Warning:
Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
Warning:
Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
Warning:
Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading of the circuits might have on overcurrent protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing
this concern.
Caution:
If installed in a closed or multi-unit rack assembly, the operating ambient temperature of
the rack environment may be greater than room ambient. Therefore, consideration should be given
to installing the equipment in an environment compatible with the maximum ambient temperature
(Tma) specified in
Specifications, page
34
APSolute Vision Installation and Maintenance Guide
73.
Document ID: RDWR_APSV_V400_IG1808