Summary of Contents for Drivecon Crane Commander Series
Page 1
0 2 7 2 5 ' 5 , 9 ( 6 $ 1 ' & 2 1 7 5 2 / 6 RANE OMMANDER Series AC Crane/Hoist Drives INSTRUCTION MANUAL Rev. 2-8-02 "the Sine of Quality"...
Page 3
DANGER! The Crane Commander inverter contains hazardous internal voltages and should be serviced only by qualified personnel. Most components are not user serviceable therefore, consult Drivecon Corporation if a problem should arise.
Page 5
Thank You! DANGER! Hazardous voltage within can cause serious injury or death. Operating drive from keypad may disable safety circuits and result in danger or injury. Only qualified personnel should work on this equipment after familiarization with its operation. Turn OFF and lock out power at main panel. Allow capacitors to bleed off prior to servicing.
Page 13
∆ Minimum Minimum H: Calori- surface area surface area Heat loss of Metric value Necessary S: Vent port in² steel in² plastic ∆ ∆ inverter of heat ventilation area enclosure enclosure ∆ (Watts) at radiated by volume (Minimum without without full load* inverter.* = 10°C...
Page 23
Terminal Terminal Description Function Comments Designatio Use L1 and L2 CC-200 series: single phase 1 phase/ 3 phase, 200-240 VAC +/- input 10% *1 L1(R) Input terminals of AC 50/60 Hz +/- 5% L2(S) line power CC-400 series: L3(T) 3 phase, 380-460 VAC +/- 10%(not to exceed) 50/60 Hz +/- 5% Never connect...
Page 24
Capacity of build-in Inverter Type Resistance (ohm) Braking torque % resistor (Watt) CC-204 CC-207 CC-207 CC-215 CC-222 CC-237 CC-255 CC-275 CC-2110 CC-2150 Without braking resistor or module 15~20 CC-2220 CC-404 CC-407 CC-415 CC-422 CC-437 CC-455 CC-475 CC-4110 CC-4150 Without braking resistor or module 15~20 CC-4220...
Page 25
FULL RESISTOR & OVERLOAD KIT RESISTOR SIZE HEATER VFD MODEL THERMAL O/L PART NUMBER (HxWxD) NUMBER RATING DBK1-450-400-* CC-404 4"x4"x14" 0.9A DBKC1-450-400-* DBK1-450-400-* CC-407 4"x4"x14" 0.9A DBKC1-450-400-* DBK1-450-400-* CC-415 4"x4"x14" 0.9A DBKC1-450-400-* DBK1-300-400-* CC-422 4"x4"x14" 1.1A DBKC1-300-400-* DBK1-160-500-* CC-440 5"x7"x12" 1.7A DBKC1-160-500-* DBK1-120-800-*...
Page 26
FULL RESISTOR & OVERLOAD KIT RESISTOR HEATER VFD MODEL THERMAL O/L PART NUMBER SIZE (HxWxD) NUMBER RATING DBK1-110-400-* CC-204 4"x4"x14" 1.8A DBKC1-110-400-* DBK1-110-400-* CC-207 4"x4"x14" 1.8A DBKC1-110-400-* DBK1-110-400-* CC-215 4"x4"x14" 1.8A DBKC1-110-400-* DBK1-70-400-* CC-222 4"x4"x14" 2.2A DBKC1-70-400-* DBK1-46-800-* CC-237 5"x7"x12" 4.2A DBKC1-46-800-* DBK1-46-800-*...
Page 27
Insure all power sources are removed from Crane Commander and system and that D.C. bus is discharged prior to handling Crane Commander inverter.
Page 32
Ramp to stop Coast to stop Ramp to stop DC injection off DC injection enable Fn53 does not equal 0 Fn54 does not equal 0 does not equal 0 Fn55 does not equal 0...
Page 34
Fn30 Fn30 )Q Jumper 2 Remote frequency command signal Remark 0-10V analog signal Jumper 2 - open circuit Effective in remote 10K ohm variable resistor frequency 1-5VDC analog signal command Jumper 2 - open circuit (Fn11=1) only. 4-20mA analog signal Jumper 2 -short circuit...
Page 36
Model: (Sheet 1 of 2) Crane Commander Setting Sheet Serial #: FIELD CODE DESCRIPTION RANGE SET UNIT HOIST TRAVERSE NOTE SETTING Fn00 'Command Link' ID No. 0~32 Fn01 Primary Accel. Time 0.1-800.0 sec. 0.1 sec. 3 sec. 5 sec. Fn02 Primary Decel.
Page 37
Model: (sheet 2 of 2) Crane Commander Setting Sheet Serial #: FIELD CODE DESCRIPTION RANGE SET UNIT HOIST TRAVERSE NOTE SETTING Fn44 Full Scale Meter Output 1-180Hz 0.1 Hz 60 Hz 60 Hz Fn45 Meter Output Calibration 0~250 0: 5th speed 1: RESET 2: 'Inch Commander' 3: 'Speed Commander'...
Page 38
Digital Operator Key Operation Description Display *Enter program mode PRGM )Q *Display the current function (Fn) code *Press up or down keys to select ∧ ∨ )Q keys the desired function code. *Display the current function READ parameter.
Page 39
Digital Operator Key Operation Description Display PRGM *Enter program mode FnXX (Fn) *Display the current function code *Select the Fn6 by pressing up or down ∧ ∨ keys Fn 6 keys to select the desired function code. READ *Display the paramter of Fn6 ENTER *DATA lamp light 60.0...
Page 57
Fn53 Fn53 Fn54 Fn53 Fn54 Fn54=0 Fn54=1-10 Fn54 Code Fn53 Code Fn54 Code Fn55 Stopping mode. Ramp to stop and DC Does not equal 0 Does not equal 0 Does not equal 0 injection brake. Does not equal 0 Ramp to stop only. Coast restart time * Coast to stop.
Page 60
Fn80 Fn81 Fn82 Fn83 Fn84 Key Operation Description Digital Operator Display Press RESET & Return all the function parameters to READ key at default setting, including parameter ENTER lock Fn59, freq. lock Fn60 & fault ;;;; the same time sequence reference Fn61.
Page 61
Digital Operator Key operation Description Display 1. PRGM * Enter program code )Q;; * Display the current function code ∨ ∧ * Select the Fn61 by pressing up )Q keys and down keys 3. READ * Refer to the first fault code ;;;...
Fn10=1, Fn46=5 Fn10=0 Fn10=1 Digital operator Key operation Description display ;;;; Emergency Stop Press STOP & REV Inverter stops keys simultaneously Coasts to stop (base block) 6W3 DANGER! Hazardous voltage within can cause serious injury or death. Operating drive from keypad may disable safety circuits and result in danger or injury.
Page 63
Digital operator Key operation Description display ;;;; 1. Connect to power supply Inverter enters stopping mode 2. Set Fn10=0 Digital operator control mode 3. Set Fn11=0 Digital operator frequency command 4. Set Fn25=5 or press up Set master frequency = 5Hz or down keys directly to 5Hz.
Page 64
)Q )Q Inverter is controlled by Operation frequency is set by Digital operator Digital operator (Fn25) Digital operator Remote frequency command Remote control terminal (TM2)24VDC or (TB1) 120VAC Digital operator (Fn25) (24VAC) Remote control terminal (TM2)24VDC or (TB1) 120VAC Remote frequency command (24VAC) Remote control terminal (TM2)24VDC or (TB1) 120VAC...
Page 65
Fn10=0 Fn11=0 Digital Operator Operation Procedure Description Display ;;;; * Inverter accelerates from 1Hz to FWD (or) preset frequency of Fn25. * Reverse run is effective when Fn33=0 momentary * Must hold button in since both are momentary type. * During stop mode frequency set ...
Digital Operator Operation Procedure Description Display 1. If Fn7=0 FnSET goes to 0 Hz 2. If Fn7>0 FnSET goes to Fn7 0.00 XX.XX...
Page 67
Fn61 Fault code Content Probable cause What to do Remark 1. Install RC type suppressor Control board failure 1. High electrical noise &3) on all contactor/brake coils. 1. Try to amend function parameters or frequency settings by Fn17-25 while 1. Set Fn60=0 Function parameter of function parameter is locked.
Page 68
Fault code Content Probable cause What to do Remark 1. Clear short circuit 1. Motor is shorted Over current during 2. Replace inverter 2. Inverter output transistor is 2&6 starting 3. Remove the grounded shorted. circuit 3. Motor is grounded. 1.
Page 69
Fault code Content Probable cause What to do Remark 1. Try to change frequency ∧ ∨ by pressing keys 1. Fn11=0. when Fn11=1. 2. CPU version (Fn64) can’t 2. Try to change CPU version be changed. ∧ ∨ Operation error by pressing @ Ã...
Page 71
DANGER! Hazardous voltage within can cause serious injury or death. Operating drive from keypad may disable safety circuits and result in danger or injury. Only qualified personnel should work on this equipment after familiarization with its operation. Turn OFF and lock out power at main panel. Allow capacitors to bleed off prior to servicing.
Page 72
DANGER! Hazardous voltage within can cause serious injury or death. Operating drive from keypad may disable safety circuits and result in danger or injury. Only qualified personnel should work on this equipment after familiarization with its operation. Turn OFF and lock out power at main panel. Allow capacitors to bleed off prior to servicing.
Page 73
DANGER! Hazardous voltage within can cause serious injury or death. Operating drive from keypad may disable safety circuits and result in danger or injury. Only qualified personnel should work on this equipment after familiarization with its operation. Turn OFF and lock out power at main panel. Allow capacitors to bleed off prior to servicing.
Page 79
DANGER! Hazardous voltage within can cause serious injury or death. Operating drive from keypad may disable safety circuits and result in danger or injury. Only qualified personnel should work on this equipment after familiarization with its operation. Turn OFF and lock out power at main panel. Allow capacitors to bleed off prior to servicing.
Page 80
DANGER! Hazardous voltage within can cause serious injury or death. Operating drive from keypad may disable safety circuits and result in danger or injury. Only qualified personnel should work on this equipment after familiarization with its operation. Turn OFF and lock out power at main panel. Allow capacitors to bleed off prior to servicing.
Page 81
Model: (Sheet 1 of 2) Crane Commander Setting Sheet Serial #: FIELD CODE DESCRIPTION RANGE SET UNIT HOIST TRAVERSE NOTE SETTING Fn00 'Command Link' ID No. 0~32 Fn01 Primary Accel. Time 0.1-800.0 sec. 0.1 sec. 3 sec. 5 sec. Fn02 Primary Decel.
Page 82
Model: (sheet 2 of 2) Crane Commander Setting Sheet Serial #: FIELD CODE DESCRIPTION RANGE SET UNIT HOIST TRAVERSE NOTE SETTING Fn44 Full Scale Meter Output 1-180Hz 0.1 Hz 60 Hz 60 Hz Fn45 Meter Output Calibration 0~250 0: 5th speed 1: RESET 2: 'Inch Commander' 3: 'Speed Commander'...
Page 83
Terminal Function List Terminal Terminal name Function and Description number CC-200: 1 phase/3 phase, 200-230VAC +/- 10% CC1-200: 3phase, 200-230VAC +/- 10% L1/L2/L3 Input terminal 50/60 Hz +/- 5% (R,S,T) CC-400: 3 phase, 380-460VAC +/- 10% 50/60 Hz +/- 5% CC-200: 3 phase, 200-230VAC T1/T2/T3 Output terminal...