Page 1
S t a b i l i z a t i o n N e t w o r k H M 6 0 5 0 - 2 Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com Hameg HM6050-2D Shown...
Operating conditions ..............Warranty and repair ............... Operating controls of the HM6050-2 ........Rear panel ..................Safety hints ..................RS-232 Interface ................RS-232 Commands ............... Setting into operation ..............EMC measurement procedures for LISN HM6050-2 ....Subject to change without notice...
HAMEG instruments fulfill the regulations of the EMC directive. The conformity test made by HAMEG is based on the actual generic- and product standards. In cases where different limit values are applicable, HAMEG applies the severer standard. For emission the limits for residential, commercial and light industry are applied.
D - 63533 Mainhausen Nombre y dirección del fabricante Die HAMEG GmbH / HAMEG S.a.r.l bescheinigt die Konformität für das Produkt The HAMEG GmbH / HAMEG S.a.r.l herewith declares conformity of the product HAMEG GmbH / HAMEG S.a.r.l déclare la conformite du produit La empresa HAMEG GmbH / HAMEG S.a.r.l.
LISN together with a Spectrum Analyzer/EMC between the signals, the selected one will Receiver. The DUT (device under test) must be available at the HM6050-2’s test signal be connected directly to the LISN. Inside the outlet. The stabilization network (simulation...
Specifications HM6050-2 Frequency range: 9 kHz to 30 MHz Network inductance: Z = 50 II (50 µH + 5 ) error < 20% acc. to VDE 0876T1 Max. current: 2 x 16 A continuous Voltage: 230 V~ at 50/60 Hz...
Safety Class 1 regulations. To put the HM6050-2 to operation it has to be connected to an AC power outlet (with protective ground) according to VDE-0100. Due to the relative high leakage current (ca. 800 mA) the equip- ment cannot be operated in combination with a leakage current circuit breaker.
Replacement of fuses The internal power supply unit of the HM6050-2 contains a fuse. Ex factory the HM6050-2 is set to 230V ±10% (50-60Hz). If the instrument shall operate at a mains voltage of 115 V ±10%, the wire bridges have to be changed by soldering.
HAMEG customer service for repairs and spare parts. Return Material Authorization (RMA): Before sending back your instrument to HAMEG do apply for a RMA number either by fax or on the Internet: http://www.hameg.de. If you do not have suitable packaging for the instrument on hand please contact the HAMAG sales department (Tel.: +49 (0) 6182/800 300,...
AC power cable. (3) Mains power outlet for the DUT The DUT will be connected to the HM6050-2’s Mains power outlet with its AC power cable. The maximum supply current of the DUT must not exceed a continuous current of 16 A at an ambient temperature of 23 °C.
Page 11
(11) Test Receiver (test signal output) The output impedance Z of the HM6050-2’s test signal output is 50 . The shielding connection of the BNC jack is connected to the housing and thus to ground. A two plug broadband BNC cable is used to attach the HM6050-2 to a Test Receiver or Spectrum Analyzer.
Rear panel (14) AC power cable The power cable is used to attach the HM6050-2 to the mains outlet. ( See: “Setting into operation” ). (15) Ground block The ground block is made of aluminum and fastened to the backside of the housing by two screws (below the mains cable outlet).
Read the operator’s manual before setting up the HM6050-2! Only qualified personnel are allowed to set up the LISN for operation. HM6050-2 has been designed in conformity to regulations VDE 9876 and CISPR Publ. 16. The leakage current of the instrument exceeds the allowed value of 0.5 mA...
IEC364-4-41 (CENELEC HD 384.4.41 and VDE 0100 Part 410). Due to the circuitry of the HM6050-2 a maximum leakage current of 800 mA can occur. It is not possible to operate the HM6050-2 at a mains outlet with a leakage current circuit breaker. Attention! Danger of death! The LISN has to be grounded according to the regulations (Cenelec HD384/DIN VDE0100) separately;...