Adjustment After Installation - Toto TBV03429B Installation Manual

Wall-mounted thermostatic faucet (for use in bathroom)
Hide thumbs Also See for TBV03429B:
Table of Contents

Advertisement

7

. Adjustment after installation

-1
1. Check of water flow
After the completion of mounting, open
the main valve of the pipes and check if
water comes out from the spout and the
shower.
2. Clean the filter and cap of the water discharge port.
When finished mounting the product, be sure to clean the filter and the
cap of the water discharge port.
If the filter and the discharged water cap are clogged, the flow rate
decreases or only cold water or scalding hot water comes out. Thus, the
product will not be able to exert the sufficient performance.
Please explain to the customer to clean the product from time to time.
*When cleaning the filter, close the main valve surely and dismount the filter.
In addition, make sure that the left side of the main unit body and the mounting
legs of the hot water side are not hot.
(For details, please refer to "Daily Care" in the instruction manual.)
*When removing the discharged water cap, do not use a thin-tipped tool such as a
flat-blade screwdriver, etc.
Mounting leg
Mounting leg
Filter
Water faucet body
Shower side
Spout side
Spout
Spout
Packing
Water
Cap of discharged
discharge
water port
port
Loosen
Round-plate-like
object
Flat-head
screwdriver
3. Check the discharged water temperature
The temperature control handle is set at the factory, but the water
discharge temperature may not be as displayed due to the conditions of
use (cold/hot water supply pressure and temperature).
Check the temperature as follows.
1. Set the safety button of the
temperature control handle
to "40" on the scale of the
main unit.
2. Turn the (open/close)
changeover handle up to the
upper limit.
Water comes out from the shower.
3. Check the water discharge
temperature.
If the water discharge temperature is
about 40 °C, use the product as it is.
If the temperature is low, raise the
set temperature of the hot water
supplier until 40 °C hot water comes
out.
To prevent scalding, set the hot
water supply temperature of the hot
water supplier to a temperature not
exceeding 60 °C.
Even if the temperature of the hot
water supplier at higher than 50 °C,
the handle setting is necessary if the
temperature is low.
Safety button
"40"
Temperature
control handle
(Open/Close)
changeover
handle
Upper (Shower side)
About 40 °C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tbv03431bTbv03427b

Table of Contents