  • Page 1 BDD-UM 3023 english User‘s Guide...
  • Page 2 War ran ty For de li ver ed pro ducts our "All ge mei ne Lie fe rungs- und Zah lungs be din gun gen" are ef fec ti ve. In no event we or our supp liers shall be li ab le for any ot her da ma ges what soe ver (in clu ding, wit hout li mi ta tion, da ma ges for loss of bu si ness pro fits, bu si ness in ter rup ti on or ot her pe cu nia ry loss) ari sing out of or ina bi li ty to use this pro duct.
  • Page 3: Table Of Contents

    Con tents 1. Di scrip ti on ......4 2. Sa fe ty in struc tions ..... . . 4 2.1.
  • Page 4 7.1.1. Sca ling the dis play ran ge ....12 7.2. Tare functi on ......13 7.3.
  • Page 5: Discription

    1. Discription Discription The di gi tal pa nel me ter mo del BDD-UM 3023 is an uni ver sal in stru ment for mea - su ring ana log in put si gnals li sted be low: • Vol ta ge 0 - 10 V •...
  • Page 6: Explanation Of Symbols

    3. Mounting 2.1. Explanation of symbols Cau ti on At ten ti on In struc tion Hint Cau ti on: Dan ge rous! At ten ti on: Will cau se da ma ge In struc tion: If not no ti ced, trouble may oc cur. Hint: Use ful hints for bet ter ope ra ti on.
  • Page 7: Electrical Connections

    4. Electrical connections 96,0 Panel cutout +0,8 92,0 15,0 55,5 Electrical connections 4.1. General Instructions • It is for bid den to plug or un plug con nec tors with vol ta ge applied • At tach in put and out put wi res to the con nec tors only wi thout vol ta ges applied •...
  • Page 8: Hints Against Noisy Enviroment

    4. Electrical connections 4.2. Hints against noisy enviroment All in puts and out puts are pro tec ted against noisy en vi ron ment and high vol ta ge spikes. Ne vert he less the lo ca ti on should be se lec ted to en su re that no ca pa ci ti ve or in duc ti ve in ter fe rence can have an ef fect on the in stru ment or the con nec tion li nes.
  • Page 9: Connection Of Input Signals

    4. Electrical connections Pin as signment: Signal input voltage ground Signal input current Supply voltage (-) Signal ground Supply voltage (+) 4.4. Connection of input signals 4.4.1. Input voltage 0 - 10 V 1: 10 V 3: 0 V 4.4.2. Input current 0 - 20 mA, 4 - 20 mA 2: + 0/4 - 20 mA 4.5.
  • Page 10: Start-Up

    5. Start-Up 5. Start-Up At ten ti on must be paid that the po wer supply vol ta ge applied will agree with the vol ta ge no ti ced at the type pla te. Switch the po wer supply on (supply vol ta ge applied to 5 (-) and 6 (+)). When de li vered, the in stru ment is pro gram med with a stan dard con fi gu ra ti on (de - fault con fi gu ra ti on).
  • Page 11: Programming

    7. Programming LED1 LED2 Description dark The displayed value is not tared lights The displayed value is tared yellow-orange green/flashes Programming mode is activated Programming The ope ra ti on and the pro gram ming of the pa nel me ter is or ga nized in se veral pro gram ming levels.
  • Page 12: Pro Gram Ming Le Vel For Con Fi Gu Ra Ti On 0-00

    7. Programming Se lec tion of a pa ra me ter • se lect the pa ra me ter by pres sing “+” -bu tton oder “-” -bu tton • Con firm the pa ra me ter by pres sing the “P” -bu tton. •...
  • Page 13 7. Programming 7.1.1. Scaling the display range Over- and un der flows are dis played as fol lows: An over flow is dis played as nnnn; this oc curs if: • the in put si gnal ex ceeds the per mis si ble ma xi mum around more than 0,5V or 1mA;...
  • Page 14 7. Programming 7.2. Tare function The tare func tion works as fol lows: pus hing the tare but ton will store the dis played va lue in the tare me mo ry. The tare va lue will be sub strac ted from the mea su red va lue.
  • Page 15 8. Technical specifications Technical specifications Analog input Resolution : 12 Bit Input ranges voltage : 0 to 10 V, ± 0,05 %, ± 1 Digit impedance : > 50 k current : 0/4 to 20 mA, ± 0,05 %, ± 1 Digit impedance : 10...
  • Page 16 CN Service Center Global Service Center Germany Germany China Balluff GmbH Balluff GmbH Balluff Inc. Balluff (Shanghai) trading Co., ltd. Schurwaldstrasse 9 Schurwaldstrasse 9 8125 Holton Drive Room 1006, Pujian Rd. 145. 73765 Neuhausen a.d.F. 73765 Neuhausen a.d.F. Florence, KY 41042 Shanghai, 200127, P.R.