JVD TRUSTEE Original Instructions Manual

JVD TRUSTEE Original Instructions Manual

Hide thumbs Also See for TRUSTEE:

Advertisement

Available languages

Available languages

Coffre-fort / Safe
Modèles / Models :
Notice original /
Lire et conserver cette notice / Read and save these instructions
3 RUE DES BRECHES – 44400 REZE - FRANCE
GUARDIAN – TRUSTEE
ICONIC - FORTRESS
Original instructions
Dernière mise à jour / Last update : 28/02/2019
Tél. +33 (0)2 40 75 98 20
www.jvd.fr
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRUSTEE and is the answer not in the manual?

Questions and answers

Summary of Contents for JVD TRUSTEE

  • Page 1 Coffre-fort / Safe Modèles / Models : GUARDIAN – TRUSTEE ICONIC - FORTRESS Notice original / Original instructions Lire et conserver cette notice / Read and save these instructions Dernière mise à jour / Last update : 28/02/2019 3 RUE DES BRECHES – 44400 REZE - FRANCE Tél.
  • Page 2: Instructions Importantes

    Lisez attentivement les instructions suivantes avant d'utiliser le coffre et conservez ce manuel pour y faire réference ulterieurement. L’objet de ce manuel est de préciser comment fonctionnent les coffres de sureté GUARDIAN, ICONIC, TRUSTEE, TRUSTEE LAPTOP et FORTRESS. DESCRIPTION et FORTRESS Les coffres GUARDIAN, ICONIC, TRUSTEE, TRUSTEE LAPTOP composent d’une boite métallique et d’une porte dont l’épaisseur est renforcée.
  • Page 3: Utilisation Normale

    2. Fermer le coffre Ouvrir le coffre avec la télécommande (fonction « EMER OPEN ») ) 3. L’heure et la date sont alors automatiquement transférées de la télécommande au coffre UTILISATION NORMALE Fermeture  Pousser la porte jusqu’en butée.  Taper un code de 4 à 6 chiffres (tous les coffres) ou passer une carte (Guardian) de droite à...
  • Page 4  Allumer l’Unité de Service.  Appuyer sur une des deux flèches et choisir « EMER OPEN ». Appuyer sur « ENTER » pour valider ce choix.  Entrer le Code Manager  Entrer un des 3 Codes de Sécurité. ...
  • Page 5 Fonction « EMER OPEN » Cette fonction permet d’ouvrir le coffre, qu’il soit bloqué ou non, dans les cas suivants :  Oubli de code  Piles faibles Pour ouvrir le coffre :  Allumer l’Unité de Service.  Appuyer sur une des deux flèches et choisir « EMER OPEN ». Valider par « ENTER ». ...
  • Page 6: Limites De La Garantie

    - par une modification du produit sans accord de JVD, - par une utilisation contraire aux instructions d'usage données par JVD - par des problèmes causés par l'utilisation de pièces ou composants non fournis par JVD. Page 6...
  • Page 7: Important Instructions

    IMPORTANT INSTRUCTIONS Read the following instructions carefully before using the safe and keep this manual for future reference. The purpose of this manual is to explain precisely how the GUARDIAN, ICONIC, TRUSTEE, TRUSTEE LAPTOP and FORTRESS safes work. DESCRIPTION and FORTRESS...
  • Page 8: Normal Use

    This step is essential for using the "AUDIT" function of the service unit. If this step is not carried out then the date and time of the operations audited will be false and unusable. To program the date and time of the safe, you must: 1.
  • Page 9: Service Unit

    Opening the safe with the service unit A closed safe can always be opened with the service unit.  Open the cover by sliding to the right (except for Fortress safe).  Connect the service unit to the safe.  Switch on the service unit. ...
  • Page 10 The purpose of the service unit Opening safes The service unit is used to open locked or unlocked safes in the following cases:  forgotten code  flat batteries Safe audits The service unit can be used to audit the last 200 operations on a safe. The operations can be consulted directly on the service unit or via the safe software after download to the safe software.
  • Page 11  “Supervisor” appears on the screen. Enter the current Supervisor Code : 1234 by default. Press "ENTER" to confirm.  Then you can change the Manager Code (Mgr Code) or the 3 Security Codes (Sec 1, Sec 2 and Sec 3) ...
  • Page 12: Scope Of Warranty

    - changes made to the product without JVD's approval, - usage that does not follow the instructions given by JVD - problems caused by the use of parts or components not supplied by JVD. Page 12...
  • Page 13: Wichtige Hinweise

    GUARDIAN, ICONIC, TRUSTEE, TRUSTEE LAPTOP und FORTRESS. BESCHREIBUNG Die Safe-Modelle GUARDIAN, ICONIC, TRUSTEE LAPTOP und FORTRESS bestehen aus einem Metallgehäuse mit einer extra dicken, verstärkten Tür. Die Kommunikation mit dem Safe funktioniert über das Display, die Tastatur oder eine Magnetkarte (Modell GUARDIAN).
  • Page 14 Schließen des Safes • Schließen Sie die Tür. • Geben Sie einen 4- bis 6-stelligen Code ein (alle Safes) oder ziehen Sie eine Karte (Modell Guardian) von links nach rechts mit dem Magnetstreifen nach unten. • Auf dem Display erscheint "CLOSE" und anschließend noch einmal der Code. Der Safe schließt nun automatisch.
  • Page 15 • Öffnen Sie die Abdeckung, indem Sie nach rechts schieben. • Schließen Sie die Serviceeinheit an der USB-Schnittstelle des Safes an. • Schalten Sie die Serviceeinheit ein. • Drücken Sie einen der beiden Pfeile und wählen Sie "EMER OPEN". Drücken Sie zur Bestätigung "ENTER".
  • Page 16 Energieversorgung Die Wartungseinheit verfügt über vier Alkaline AA (LR6) -Batterien. Wenn die Batterien fast leer sind und ausgetauscht werden müssen, wird der Bildschirm ausgeblendet und "Battery Low" (“BA-LO“) angezeigt. Sichere Auditierung Die Serviceeinheit kann genutzt werden, um die letzten 200 Vorgänge an einem Safe zu überwachen.
  • Page 17 Code-Änderung für Notöffnung (unbedingt empfohlen!) Gehen Sie folgendermaßen vor, um den Security2-Administratorcode zu ändern: • Schalten Sie die Serviceeinheit ein. • Drücken Sie einen der beiden Pfeile und wählen Sie "SETTING". Drücken Sie zur Bestätigung "ENTER". • Wählen Sie "2. Emer open". Drücken Sie zur Bestätigung "ENTER". •...
  • Page 18 - Schaden durch externe Einwirkung, z.B. Unfall, Missbrauch, vernachlässigte oder nicht durchgeführte Wartung, Abnutzungserscheinungen, Alterung, Bruch, Vandalismus, etc. - Schaden nach Produktveränderungen ohne vorherige Genehmigung durch JVD - Nutzung des Artikels unter Nicht-Beachtung der JVD-Anleitung - Schadensverursachung durch die Nutzung von Teilen oder Komponenten anderer...