Universal setting cable for tubular motors
Translation of the Original Operating Manual for setting the
RolloTube C/M/S-line tubular motors
Item no. 9600 00 86
Risk of fatal electric shock when touching electrical
components.
◆ The connection of the tubular motor to the universal
�����������������������������
to the mains may only be undertaken by an authorised
�����������
◆ Carry out all connection work only in an isolated, de-ener-
gised state.
◆ Disconnect all phases of the mains power lead and se-
cure it to prevent any reconnection.
◆ Check that the system is de-energised.
Intended use
Use the universal setting cable only for commissioning, end
point setting or adjusting the end points of RADEMACHER
tubular motors.
Improper use
Do not use the universal setting cable:
◆ for the permanent control of a tubular motor.
◆ for the connection and control of other electrical appliances.
T�����������
Operating voltage:
Max. switching capacity:
Permissible
ambient temperature:
Permissible
storage temperature:
Protection class:
DANGER!
230 V / 50 Hz
6 (4) A / 250 V AC 1E4
0 to 40°C
-10°C to +60°C /
Relative humidity: max. 90%
II (only for use in dry rooms)
The universal setting cable is designed for commissioning, end
point setting or adjusting the end points of RADEMACHER
tubular motors.
Support for the new C-line, M-line and
S-Line tubular motor generation with:
◆ Sensor function
◆ Single-hand operation possible
◆ Connection with the same colours
◆ Manual end point setting
Support for current RADEMACHER tubular motors:
The current generation of RolloTube I-line (DuoFern),
X-line motors are also supported.
You can obtain further information on
our support for the current
RADEMACHER tubular motors on our
website www.rademacher.de or
simply scan this QR-Code:
Button assignment
Button 2
Button 1
C-line / M-line
Button 1
Direction of travel I / II
Button 2
Button 3
No function
Pin assignment
The connection is made with the same colours as the motor con-
necting cable of the respective RolloTube tubular motor.
Before you begin the work, please read the detailed
operating manual of the respective tubular motor and
follow all the safety instructions and installation
instructions.
black
L1
brown
L1
blue
N
Neutral terminal
green/yellow
PE
Earth
grey or white
varies depending on motor
1.
Open the terminal contacts by pressing the plungers and
connect all the wires of the motor cable with the same col-
ours and corresponding to their functions.
2.
Then insert the mains plug into the mains socket.
Button 3
S-line
Set button
Continuous phase
(Direction of travel 1)
(Direction of travel 2)
VBD 702-2-1 (10.19)