Gas Conversion Kits - Intertherm Millivolt DMSTNM-2 Installation Instructions Manual

Designer direct vent multi-open
Table of Contents

Advertisement

GAS CONVERSION KITS

WARNING: THIS CONVERSION KIT SHALL BE
INSTALLED BY A QUALIFIED SERVICE AGENCY IN
ACCORDANCE WITH THE MANUFACTURER'S IN-
STRUCTIONS AND ALL APPLICABLE CODES AND
REQUIREMENTS OF THE AUTHORIZED AGENCY
HAVING JURISDICTION. IF THE INFORMATION IN
THESE INSTRUCTIONS IS NOT FOLLOWED EX-
ACTLY, A FIRE, EXPLOSION OR PRODUCTION OF
CARBON MONOXIDE MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS
OF LIFE. THE INSTALLATION IS NOT PROPER AND
COMPLETE UNTIL THE OPERATION OF THE CON-
VERTED APPLIANCE IS CHECKED AS SPECIFIED IN
THE OWNER INSTRUCTIONS SUPPLIED WITH THE
KIT. THE QUALIFIED SERVICE AGENCY PERFORM-
ING THIS INSTALLATION ASSUMES RESPONSI-
BILITY FOR THIS CONVERSION.
f i r e - p a r t s . c o m
In Canada:
THE CONVERSION SHALL BE CARRIED OUT
IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CAN1-B149.1
AND .2 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EFFECTUÉE
CONFORMÉMENT AUX RECOMMANDATIONS
DES AUTORITÉS PROVINCIALES AYANT
JURIDICTION ET CONFORMÉMENT AUX
EXIGENCES DU CODE D'INSTALLATION CAN1-
B149.1 ET.2.
The natural to LP/propane gas conversion
kit is supplied with the fireplace. The kit
contains all the necessary components
needed to complete the conversion process,
including labeling that must be affixed to
ensure safe operation.
26
AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION
SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE
CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET
TOUTES EXIGENCES ET CODES APPLICABLES DE
L'AUTORISÉS AVOIR LA JURIDICTION. SI L'INFORMATION
DANS CETTE INSTRUCTION N'EST PAS SUIVIE
EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE
PROTOXYDE DE CARBONE PEUT RÉSULTER LE DOMMAGES
CAUSER DE PROPRIÉTÉ, PERTE OU BLESSURE
PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE DE SERVICE
EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET
ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET
COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL
CONVERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS
DANS LES INSTRUCTIONS DE PROPRIÉTAIRE
PROVISIONNÉES AVEC L'ÉQUIPEMENT.
The following steps detail the conversion
procedure:
Step 1. Turn off the gas supply to the appliance.
a. Open the control compartment access panel,
by actuating the spring-loaded magnetic
catches securing the panel, gently depress-
ing the outer top corners of the panel until
the catches "pop" the panel free and allowing
it to swing out and down to open.
b. Locate the two (2) latches at the top of the
control compartment. To disengage the two
latches from the bottom vee-flange of the
glass enclosure panel, reach for the handles
located towards the back of the latches and
pull the handles down toward the front of the
unit.
c. Swing the bottom of the door out and raise
it slightly to lift the top flange of the door
frame away from the appliance.
Step 2. Carefully remove the log set. Exercise
care as not to break the log set.
Step 3. Referring to Figure 55 remove the
front burner and then the rear burner.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 55
Millivolt Appliances
Step 4. Refer to Figure 56 on page 27 and the
instructions provided with the kit. Using a Torx
T20, remove and discard the three pressure
regulator mounting screws. Remove the pres-
sure regulator, spring, poppet, diaphragm and
bushing. Discard all removed components.
Ensure the rubber gasket installed on the back
of the replacement pressure regulator is prop-
erly positioned and install the new pressure
regulator using the new screws supplied with
the kit. Tighten screws to 25 In. lb. torque.