INSTRUCTION MANUAL Be sure to read through this manual to gain full understanding before proceeding to actual operation. Please retain this manual for future reference. SAFETY PRECAUTIONS Read the precautions carefully before operating the air pump. The contents of this section are vital to ensure safety.
Page 3
For Installers Installation • CAUTION The air pump should be installed in a well ventilated place and away from direct sunlight preferably undercover. Install the air pump in a place which has neither direct rain water splashing nor water immersion.
Page 4
Test Operation • CAUTION The airline outlet area must be filled with water up to the prescribed line before turning on the air pump. Make sure the aeration is conducted properly. Make sure the air pump is making no abnormal noise and vibration. ...
Page 5
Inspection and Maintenance as required change is only permitted by trained maintenance personnel. Work on electrical components diaphragm may only be carried out by qualified electricians in accordance with the applicable regulations. (1) Air Filter (2) Diaphragm / Valve REPLACE THE DIAPHRAGM/VALVE EVERY YEAR INSPECT AND CLEAN EVERY 3 OR 4 MONTHS AND REPLACE EVERY YEAR If the diaphragm/valve becomes damaged, the automatic...
Page 6
Diaphragm Replacement Procedure 3. Remove a power cable from 3 2. Remove an auto-stop piece as 1. Remove cover bolts using a hooks. instructed above. 8mm-box wrench. Attention Do not remove screws!! 6. Place a new diaphragm using 5. Remove nut and take a 4.
Page 7
MAC40RⅡ/60RⅡ/80RⅡ Air pump Service Manual and Parts Description Exploded View and Parts List Attention: For MAC60RII & 80RII attach the oscillator so that the 80 mark is in an upward direction MAC40RII Repair Parts List Item Name 40RⅡ 60RⅡ 80RⅡ...
Page 8
MAC100RⅡ/120RⅡ Air pump Service Manual and Parts Description Exploded View and Parts List Attention: For MAC100RII &120RII attach the oscillator so that the triangle mark is in an upward direction. MAC120RII Repair Parts List Item Name 100RⅡ 120RⅡ ○ ○ H613 N8 Filter cover ○...
Page 9
MAC150RⅡ/200RⅡ Air pump Service Manual and Parts Description Exploded View and Parts List Attention: For MAC150RII attach the oscillator so that the A mark is in an upward direction. For MAC200RII attach the oscillator so that the B mark is in an upward direction. Repair Parts List Item Name 150RⅡ...
Page 10
MAC250RⅡ/ 300RⅡ Air pump Service Manual and Parts Description Exploded View and Parts List Attention: For MAC250RII &300RII(50Hz) attach the oscillator so that the circle mark is in an upward direction. For MAC300RII(60Hz) attach the oscillator so that the triangle mark is in an upward direction. Repair Parts List 300RⅡ...
Page 11
■ Specifications Model 40RⅡ 60RⅡ 80RⅡ 100RⅡ 120RⅡ Air Flow Volume L/min Normal Pressure Rated Voltage 230 - 240 Frequency 50 / 60 O.D.26mm Outlet Pipe Size O.D.18mm (I.D.13mm) (I.D.20mm) Weight Power Consumption 27 / 28 35 / 38 47 / 51 68 / 80 86 / 101 (at Normal Pressure)
Page 12
■ Overall View (all dimensions in millimeters) □ MAC 40RⅡ □ MAC 60Ⅱ/80RⅡ/100RⅡ □MAC120Ⅱ □MAC150RⅡ/ 200RⅡ/250RⅡ/300RⅡ...
FUJI CLEAN CO., LTD., 4-1-4 Imaike, Chikusa-Ku, Nagoya, Aichi 464-8613, Japan declare in sole responsibility that the product FujiMAC Air Pump, Model MAC40RⅡ, MAC60RⅡ, MAC80RⅡ, MAC100RⅡ, MAC120RⅡ, MAC150RⅡ, MAC200RⅡ, MAC250RⅡ, MAC300RⅡ complies with the provisions of the following directive: 2014/35/ EU Low Voltage Directive However, the following directive is not applicable for these products described above.