10
• Connect the hood to the mains through a
two-pole switch having a contact gap of at
least 3 mm.
• Remove the grease filters (see paragraph
Maintenance) being sure that the connec-
tor of the feeding cable is correctly insert-
ed in the socket placed on the side of the
fan.
Upper Chimney
• Slightly widen the two sides of the upper
flue and hook them behind the brackets
7.2.1, making sure that they are well seat-
ed.
• Secure the sides to the brackets using the
4 screws 12c (2,9 x 9,5) supplied.
• Make sure that the outlet of the exten-
sions pieces is aligned with the chimney
outlets.
Lower exhaust flue
• Slightly widen the two sides of the flue
and hook them between the upper flue
and the wall, making sure that they are
well seated.
• Fix the lower part laterally to the hood
body using the 2 screws 12c (2,9 x 9,5)
supplied.
Electrical Connection