  • Page 1 AMS3HO AMS3 Operation Manual KFDA.* RoHS U 189 L$Q No2670 By,KFDA...
  • Page 2: Table Of Contents

    CONTENTS '.,`" ,,' DIGITAL WATER IONIZER IMPORTANT SAFETY INSTRUCTIONS PACKAGE CONTENTS APPEARANCE AND FUNCTIONS INSTALLATION OPERATION FILTER REPLACEMENT FILTER COMPOSITION pH VALUE TEST TROUBLESHOOTING UNIT SPECIFICATIONS WARRANTY CARD UNIT CONVERSION TABLES...
  • Page 3: Important Safety Instructions

    Warning symbol indicating potential fire damage or personal injury. Caution symbol indicating safety precautions and damage to the unit" Disclaimer: AML 3000(S) Water ionizer is a water purification product. Please consult with a physician before drinking alkaline water. Please read instructions to ensure proper usage of this product.
  • Page 4 SAFETY INSTRUCTIONS O I G ITA L WATE R IO N IZE R If the unit is immersed in water, immediately pull out the power MIEII plug and then take the unit out of the water. Try to avoid an electric circuit overload of an outlet or electric...
  • Page 5 SAFETY INSTRUCTIONS .:',',',' DIGITAL WATER IONIZER Do not disassemble, repair, and/or modify. > Personal safety could be compromised. > For repairs, please contact one of our authorized sales agents. Use only sanitary and drinkable water (municipal water, etc.). "0 ( !" ) Before operating the unit, allow the unit to perform water input and output for 2 ~ 3 minutes.
  • Page 6 :',' '.". ,', SAFETY INSTRUCTIONS DIG|ITAL WATER IONIZER Do not put too much pressure on the power cord when you remove the cord from the socket. Keep the unit in a cool and dry condition Keep the unit clean away from dusts, hot temperature, sunlight, salts, chemicals, etc, Do not damage the shape or color of the unit.
  • Page 7: Package Contents

    PACKEAGE CQNTENS .:.',', DIGITAL WATER IONIZER AML 3000 AML 30005 Unit Body Acidic Water Outlet Hose & Oneouch Check Valve Water Diveer Source Water Inlet Hose Fitting Safety Key * Accessories are subject to change depending on the product specification.
  • Page 8: Appearance And Functions

    3. LCD Screen (Function Indicator) 4. Touch Buttons 5. Operation Knob(Water Supply Control Valve) 6. Alkaline Water Outlet Dispenser (AML 3000 : Swing Type, AML 30008 : Flexible SUS Tube Type) 7. Filter Connection Terminal A filter cartridge must be connected to the terminal when the filter is replaced.
  • Page 9 APPEARANCE AND FUNCTIONS ',', ' D I G ITAL WATE R ID N IZE R 1. Filter Life Indicator Replace filter when icon flickers. Filter Authenticity Indicator - Identifies authenticity of the filter, ~ Flickers when an authentic filter is not used, 3.
  • Page 10 INSTAIIATION DIGITAL WATER IONIZER Alkaline Water comes out Main body Acidic Water __________ comes out AML 3000 Main body Acidic Water Alkaline Water comes out comes out AML 30005...
  • Page 11: Installation

    INSTALLATION ',', ' DIGITAL WATER IONIZER 1. Select a sturdy flat surface with proximity to a power outlet. Firmly connect the provided 1/4" hose to Water Inlet Port. In the case of one-touch fitting apparatus, insert the Water Inlet Pork nozzle into the hose and fasten the safety key after the connection, In the case of two-touch fitting apparatus, make sure the nut is tightly screwed to ensure a tight fit.
  • Page 12 1. Horizontally swing the dispenser arm to the front or from side to side. 2. The dispenser extended 3. The Flexible SUS Tube dispenser can be bent horizontally for two additional stretches. to the desired point. AML3OOOS AML 3000 B;GATEIT;LIDN|ZER...
  • Page 13: Operation

    OPERATION ',', ' DI G ITAL WATE R I O N I ZER Firmly plug in the Turn on Main Power Switch on the left AC power plug. side of the bottom base. > The unit will beep and LCD screen will display standby statas.
  • Page 14 OPERATION OIG,TAL WATER IONIZER Rotate Operation Knob clockwise so that the water flows into > the unit. Press Alkaline Water Button and chse the pH level by repealy touching the buHon. > Alkaline water is dispensed through Water Outlet Dispenser while acidic water is dispensed through the lower Water Outlet Hose.
  • Page 15 OPERATION '000 o DIGITAL WATER IONIZER Rotate Operation Knob clockwise so that the water flows into > the unit. > The alkaline water mode initially appears. Press "Acidic Water" Button for the acidic water outlet mode. When Acidic Water Button is touched during the purified water mode: >...
  • Page 16 TAG,,vi III,X,. OPERA ON D I G ,TAL WATER ION IZER RoWte Operation Knob docise so that the water flows into > the unit. The alkaline water mode initially appears. Press "Purified Water" BuHon for the purified water olet mode. b The unit emits a "Purified Water"...
  • Page 17 OPERATION ',', ' D I G ITAL WATER i O N I ZE R Press "Melody" Button to turn the melody sound on or off. > Touch Melody Button to mute the sound and make the icon disappear. > Touching Melody Button again will turn the sound back on and make the icon reappear on LCD screen. >...
  • Page 18: Filter Replacement

    's_,k,il.I,I,X,. FILTER REPLACEMENT D I G ITAL WATE R ID N IZ E R Turn off the water inflow into the unit. Replace the filter when Filter Lifespan Indicator flickers. > Rotate Operation Knob counter- > When the filter needs to be replaced, the filter clockwise to OFF position.
  • Page 19 FILTER REPLACEMENT .:'.',', D I G ITAL WATE R IO N IZE R Insert a new authentic filter. 1) Insert a new filter 3) Connect Filter Top cartridge. Cable with Filter Connection Terminal. Water may leak from the filter connection points when O-ring is damaged or removed. Carefully position O-rings correctly when a filter is replaced.
  • Page 20 FILTER REPLACEMENT IG IlTA L WATE R f D N f Z E R Pleamonsider replacing the filter with a new one even if Filter Life Indicator is not indicating the empty filter life ( ), if one of the following abnormal conditions occurs: >...
  • Page 21: Filter Composition

    FILTER COMPOSITION .:.',',' D I G ITAL WATE R I O N IZER 7 - Step Comprehensive Water Purification(Standard) *Sediment Step 7: Post Sediment filters big particles, substances, rust, and dirt, etc. Step 6: Post Activated Carbon *Pre-activated Carbon Step S: provides first round activated carbon filtering of impurities to Sediment improve color and tastes of water while removing odor.
  • Page 22: Phvaluetest

    :',' '.",,', pHVALuETEST DIGITAL WATER IONIZER Fill 2/3 of the provided test container or glass container with, respectively, alkaline ionized water, acidic ionized water, and tap water. Alkaline Tap Water Acidic Water Water Put 2~3 drops of pH Test Reagent into each container, and then shake the container to mix well.
  • Page 23: Troubleshooting

    TROUBLESHOOTING ',', ' DIGITAL WATER IONIZER Increase water inflow. Insufficient water inflow. Ensure that Power Plug is inserted Power Plug is not properly inserted LCD screen does correctly. not come on. Fuse is blown Replace the fuse Fuse is not properly inserted Immediately remove Plug from Power LCD screen does not turn off even Abnormal Power Circuit Board...
  • Page 24 TROUBLESHOOTING DIGITAL WATER IONIZER Filter lifespan has expired. Filter lifespan has been shortened Filter replacement is needed due to the poor quality of water. Dispensed water has a strange smell Due to sudden change of water Select pH level 1 quality and excessive chlorine in the i,e.
  • Page 25: Unit Specifications

    Product Manufacturing Permission No. No. 2670 by KFDA Product Classification Alkaline ionized Water Generator Model AML 3000 & AML 30005 AC 230V 5OHz Input Voltage (Different voltage and Hz will be available as per user's request.) Power Consumption Net Weight Approx.
  • Page 26: Warranty Card

    WARRANTY CARD DIGITAL WATER IONIZER WARRANTY CARD Product Model No AML 3000 / AML 30005 Name Purchasing Serial No Date Shop name Seller Address Name Buyer Address This product passed inspection under strict quality control. If the product has any...
  • Page 27: Unit Conversion Tables

    UNIT CONVERSION TABLES ',', ' EllEllTA L, WAT !CI NI ZE R 13'0 1 '0 17'0 30'0 10'0 11'0 -> 77.0 'F 0.13 U.S.gal 0.15 U.S.gal 0.18 U.S.gal 0.21 U.S.gal 0.23 U.S.gal > 0.26 U.S.gal 0.29 U.S.gal -> 0.31 U.S.gal 1.3 I 0.34 U.S.gal...
  • Page 28 Water used for quality tests at the factory may remain inside of the unit,iii ,,-"" ALKAMEDI CO., LTD. -gu, An! V ang-si, Gyeonggi-do 431-767, BavlaS4ey 601, 602-ho 2-ho, 266, Marketed by : SUZUION T...