Download Print this page

Data Domain DD690g Installation And Setup Manual page 2

Gateway system

Advertisement

Data Domain DD690g Gateway System
FIGurE 1:
rAck MOuNTING PrOcEDurE
1. Align locating pin (A) with rear rack post.
2. Extend rails to front of rack.
3. Secure front and rear rails to rack
posts with screws and washers (B).
4. Tighten clamp screws (C).
5. Repeat for other side of unit.
FIGurE 2:
rEAr PANEl AND INPuT/OuTPuT cONNEcTIvITY
Slot 6
Slot 5
Slot 4
PCI-e (x8)
PCI-e (x8)
PCI-e (x4)
GbE #2 or
GbE #1 or
FC
10 GbE #2
10 GbE #1
Gateway
or VTL #1
or VTL #2
HBA #1
FIGurE 3:
FrONT PANEl AND DISk lOcATIONS
Blue circles illustrate the locations of the four hot-swap disks.
All the other disk slots are filled with drive filler blanks to
ensure proper air flow through the chassis.
Hot-swap disks: Physical location:
Logical numbering:
Drive filler blanks:
3
4
7
8
9
Front Operator Panel LEDs
LED
Status
Power Active
Steady Green: Good
Unit Fault
Steady Amber: Fault
Enclosure ID
Blue: Only when activated
Slot 3
Slot 2
Slot 1
PCI-e (x4)
PCI-X
PCI-X
FC
1024 MB
Empty
Gateway
NVRAM
HBA #2
1
2
5
6
1.1
1.2
1.3
1.4
10
11
12
Front Operator Panel Buttons
Push Button
Definition
Power
Press to start boot (if system is not running).
Never shut down the system by pressing the power button.
System Reset
Resets hardware and firmware. Use ballpoint pen to activate.
Enclosure ID
Press to light a blue LED front and rear to ID chassis in a stack.
Mutes audible alarm, if active.

Advertisement