Download Print this page

OZCO 214 Manual

12x16 pavilion 6x6 posts

Advertisement

Quick Links

OZCO Project #214 -
12x16 Pavilion
6x6 Posts
roofing shown translucent for clarity
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically
Pavilion Overview
and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.

Advertisement

loading
Need help?

Need help?

Do you have a question about the 214 and is the answer not in the manual?

Questions and answers

Summary of Contents for OZCO 214

  • Page 1 OZCO Project #214 - 12x16 Pavilion 6x6 Posts roofing shown translucent for clarity V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Overview and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 3 11'3 2 " shown without roofing for clarity OZCO Project #214 - 12x16 Pavilion w 6x6 Posts V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Overview and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 4: Suggested Tools

    Suggested Tools (others may be required) V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Overview and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 5: Material List

    V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/12/2018 . This information is updated periodically OZCO Project #214 Material List and should not be relied upon after 2 years from 3/12/2018 . Please visit OZCOBP.com to get current information.
  • Page 6 Scan QR barcode with smartphone for quick access to product installation instructions V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion OZCO and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 7 Laredo Sunset & Ironwood 2 great styles Same functionality choose your connection lifestyle both styles available for most products Laredo Sunset Ironwood (566XX series) (517XX series) Laredo Sunset & Ironwood V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically and should not be relied upon after 2 years from 2/21/2017 .
  • Page 8 2 " 56° 2'10 " " 3'10 16 " 8 " 8'0" 45° 2 " 10'10" 2'6" 11'9" 56° 34° see Birds Foot template 12x(length) Pavilion cut list: common to all 12' wide Pavilions V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Cutlist 12 and should not be relied upon after 2 years from 2/21/2017 .
  • Page 9 8 " 2x6 Board 100.13" 8:12 Rafter cut 2 " 8 " 2 " 4 " 90° 56° Birds Foot 1:1 template V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Cutlist 12 and should not be relied upon after 2 years from 2/21/2017 .
  • Page 10 8 " X 45° 8 " X 45° 13'1" 9'1" 4 " 12'0" 10'0" 16'0" 8 " X 45° 12x12 12x16 12x20 12x(length) Pavilion cut list: 2x8 length wise boards V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Cutlist 12 and should not be relied upon after 2 years from 2/21/2017 .
  • Page 11 2 " 13'6 2 " Site Plan - OZCO Project #214 - 12x16 Pavilion w 6x6 Posts V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Site Plan and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 12 56636 Bolt Offset (P2B-BO-LS) OZCO Project #214 - 12x16 Pavilion w 6x6 Posts ledge V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Base and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 13 56680 Duty Washer (OWT-TBW-2) OZCO Project #214 - 12x16 Pavilion w 6x6 Posts V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Beam & Support and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 14 Building your Canopy... Simple 3 step procedure common to all size Pavilions repeat on all sides (HCN) provided Tool Required 3/8" Driver 10x10 Pavilion shown use this procedure for all size Pavilions (10x10 shown). same construction steps (OWT Timber Screw) and techniques apply provided step 1 Outer Beams...
  • Page 15 Secure with nails or screws Repeat on all sides repeat on all sides for additional beam rigidity apply polyurethane adhesive between boards step 2 Inside Beams V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Beam &...
  • Page 16 flush repeat on all sides (HCN) provided Tool Required 3/8" Driver (OWT Timber Screw) provided step 3 Knee Braces V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Beam & Support and should not be relied upon after 2 years from 2/21/2017 .
  • Page 17 56618 Rafter Clips (RC-LS-4) OZCO Project #214 - 12x16 Pavilion w 6x6 Posts Pavilion Truss 12 V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 18 Building your Truss... temporary securing of Ridge Beam necessary Simple 7 step (not shown) repeat step procedure common to all size Pavilions predrill holes use this procedure for all size Pavilions (10x10 shown). same construction steps and techniques apply Tool Required 10x10 Pavilion shown 3/8"...
  • Page 19 tip: rafter screw heads might interfere with roofing. secure flush/below rafter or modify roofing materal as needed. repeat step predrill holes Tool Required 3/8" Driver 10x10 Pavilion shown (OWT Timber Screw) step 2 V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Truss 10 and should not be relied upon after 2 years from 2/21/2017 .
  • Page 20 repeat step 2 see overview page for spacing and quantity of Trusses Tool Required 3/8" Driver 10x10 Pavilion shown (OWT Timber Screw) step 3 V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Truss 10 and should not be relied upon after 2 years from 2/21/2017 .
  • Page 21 repeat step repeat step predrill holes Tool Required 3/8" Driver 10x10 Pavilion shown (OWT Timber Screw) step 4 V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Truss 10 and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 22 repeat step repeat step on all rafters (HCN) 10x10 Pavilion shown Tool Required 3/8" Driver repeat (OWT Timber Screw) step on all rafters step 5 V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Truss 10 and should not be relied upon after 2 years from 2/21/2017 .
  • Page 23 level repeat step (HCN) Tool Required 3/8" Driver 10x10 Pavilion shown (OWT Timber Screw) step 6 V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Truss 10 and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 24 repeat step 6 on all rafters (HCN) Tool Required 3/8" Driver 10x10 Pavilion shown (OWT Timber Screw) step 7 V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically Pavilion Truss 10 and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.
  • Page 25 1x6x16'0" Board secure roofing with nails or screws OZCO Project #214 - 12x16 Pavilion w 6x6 Posts Roofed Pavilion Truss 12 Roofing V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/21/2017 . This information is updated periodically and should not be relied upon after 2 years from 2/21/2017 . Please visit OZCOBP.com to get current information.