Repair kit for transformers used on reactor proportioners

Advertisement

Removal
Removal
Use F
. 1 for the following instruction.
IG
WARNING
Repairing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Read warnings in
Reactor Repair manual. Be sure to shut off all power
to the equipment before repairing.
1. Turn main power OFF
supply.
Red wires
To circuit board
F
. 1: Removing transformer
IG
6. From the top left of transformer, remove the two
screws and nuts and remove white terminal block.
7. From connector (F), remove and discard clamp (B).
8. From connector (F), remove 8-gauge wire #3 (E).
2
. Disconnect power
B
A
WARNING
Wait 5 min for stored voltage to discharge (E-30 and
E-XP2 models only).
2. Remove Reactor front cover.
3. Remove two bolts holding transformer to frame and
slide forward for access.
4. Disconnect black, plastic, 3-pin connectors going
from back of transformer to circuit board on the left.
There are red wires on one side and black on the
other.
5. Loosen terminal screws one and two at rear of white
terminal block (located at left of transformer wire tap
terminal), and pull out black wires coming from back
of transformer.
Black wires
F
Discard
G
9. Remove and discard connector (F), wires, and white
terminal block.
10. From connector (G), remove and discard clamp (A).
11. From connector (G), remove all three red wires.
12. Discard connector (G).
To white
terminal block
E
TI5691A
309930C