Download Print this page

Hubbell GAI-TRONICS Page/Party 780-301 Manual

Handset stations for cenelec zone 1 applications

Advertisement

Quick Links

Model 780-301 and 7805-301 Page/Party
for Cenelec Zone 1 Applications
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
The assembly described in this manual is a speaker/amplifier housed in an explosion-proof cast aluminum
enclosure equipped with a handset. The assembly is designed to be installed in hazardous areas where
combustible gases exist or may exist.
The aluminum enclosure, while not gas tight, is designed to withstand repeated internal explosions
without expelling gases hot enough to ignite the external atmosphere. This is accomplished through the
use of a precision machined flame-path opening that cools the exiting gases to a temperature below the
flash point of the external, explosive atmosphere.
Application
The hazardous area Page/Party
noise areas where explosive atmospheres exist or may exist. The Model 780-301 Single Party Handset
Station and Model 7805-301 Multi-party Handset Station are BASEEFA approved to CENELEC
Standards Ex dib for Zone 1 Group IIC T5.
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374
V
ISIT WWW
G A I - T R O N I C S ®
A H U B B E L L C O M P A N Y
Handset Stations
®
Handset Station provides clear paging communications even in high
800-492-1212
.
-
.
GAI
TRONICS
COM FOR PRODUCT LITERATURE AND MANUALS
Fax: 610-796-5954
Pub. 42004-638L2
®

Advertisement

loading
Need help?

Need help?

Do you have a question about the GAI-TRONICS Page/Party 780-301 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hubbell GAI-TRONICS Page/Party 780-301

  • Page 1 Pub. 42004-638L2 G A I - T R O N I C S ® A H U B B E L L C O M P A N Y Model 780-301 and 7805-301 Page/Party ® Handset Stations for Cenelec Zone 1 Applications Confidentiality Notice This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
  • Page 2 Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 2 of 15 Hardware Configuration External When the handset is removed from the cradle, a magnetic reed switch in the cradle takes the station off-hook. In addition to the handset and cord, a push-to-page button and a label are located on the front cover.
  • Page 3 Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 3 of 15 Figure 2. Models 780-301 and 7805-301 Cable Gland Entries - Bottom View : Ensure any unused openings are sealed with proper fittings per local standards. Figure 3.
  • Page 4: Table Of Contents

    Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 4 of 15 Block Diagram Figure 4. Model 701-202-EX Handset Station Block Diagram P1 is the 16-pin male connector located on the back of the Base-16 printed circuit board assembly (PCBA).
  • Page 5 Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 5 of 15 Installation ® Before installing Page/Party equipment, design the system layout taking into consideration personnel safety, operational function, convenience, and power cable length. In general, for 115 V ac systems the total cable length should not exceed one mile (1.6 kilometer), but the length of cable between the stations is not a critical factor.
  • Page 6 Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 6 of 15 Mounting : The mounting surface must be able to support 55 lbs. (25 kg). The explosion-proof enclosure is very heavy. Handle carefully to avoid damage to the unit and personnel injury. 1.
  • Page 7 Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 7 of 15 Figure 6. Single Party Wiring Detail \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-638l2.doc 6/98...
  • Page 8 Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 8 of 15 Figure 7. Multi-Party Wiring Detail \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-638l2.doc 6/98...
  • Page 9: Party Line (L1)

    Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 9 of 15 Operation ® GAI-Tronics offers two types of Page/Party systems: Page/Single-Party with one party line and one page line, and Page/Multi-Party with five party lines and one page line allowing up to five simultaneous two- way conversations.
  • Page 10: Pg_L1 Page Line (L1)

    Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 10 of 15 Adjustments CAUTION It is necessary to open the explosion-proof enclosure to make adjustments. Make adjustments only when the conditions at your facility are such that no explosive atmospheres can be present. Any adjustment requires the removal of the cast aluminum cover.
  • Page 11: Mt_L1 Mute (L1)

    Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 11 of 15 To make these adjustments, remove the assembly from its enclosure and make a temporary connection between the assembly and the enclosure as described in the following steps: 1.
  • Page 12: C No Connection

    Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 12 of 15 Maintenance In order to verify and ensure explosion-proof integrity, perform regular preventive maintenance and inspection checks on the GAI-Tronics explosion-proof enclosure. The GAI-Tronics Field Service Department can formulate a service contract to suit specific preventive maintenance needs.
  • Page 13: Speaker (8-Ohm)

    Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 13 of 15 Troubleshooting The table below describes possible solutions for some common problems. Problem Solution Speaker level requires Adjust the Speaker Volume Control, labeled USER ADJ, at the adjustment.
  • Page 14: Speaker (16-Ohm)

    Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 14 of 15 Specifications Electrical Voltage ................90 to 140 V ac (120 V ac nominal) 50/60 Hz Power Consumed ......Zero/maximum signal (12 watts): 15 VA, 10.5 watts; 53 VA, 34 watts Speaker Amplifier Output:.................
  • Page 15: C No Connection

    Pub. 42004-638L2 ® Model 780/7805-301 Page/Party Handset Stations for Cenelec Zone 1 Applications Page: 15 of 15 Replacement Parts Model Number Description ® 10111-007 Handset Assembly with 6-foot Hytrel Cord 12511-001 Dynamic Transmitter and Cap 12530-001 Transformer/Connector Subassembly 13204-002 Receiver Cap 701-202-EX Amplifier Assembly Reference Material...
  • Page 16: Ac_N Ac Neutral

    Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document.

This manual is also suitable for:

Gai-tronics page/party 7805-301