e
system,22V in 24 system.
N
12V system: the setting range is from 10.4V to 11.4V
o.
24V system: the setting range is from 20.8V to 22.8V
6
LCD screen displays
The setting of low voltage reconnecting: If you long
state No.7
press 5s the menu button, going into the setting station
(the data flashing).By pressing the
can increase the value. By pressing the
Button
system25.6V in 24 system.
12V system: the setting range is from 12.2V to 13,2V
24V system:the setting range is from 24V to 26.4V
reduce the value.
Note: the factory default setting value is 12.8V in 12V
UP button, you
DOWN