GENERAL DESCRIPTION
The NAPCO NetLink™ GEMC-NL-MOD is a device that al-
lows the reporting of alarms over a TCP/IP based (Intranet or
Internet) network. Alarm reporting, previously performed via
Telco only, can now be performed over both a TCP/IP net-
work and/or Telco, or via the TCP/IP network as a backup.
The GEMC-NL-MOD is housed in a separate plastic enclo-
sure, and is connected to the Local Download receptacle for
the Gemini C-Series control panels.
The GEMC-NL-MOD is supported by PCD-Windows Quick-
loader download software version 6.0 or greater. For the pan-
els listed above, the Quickloader software will support
downloading through the Internet or an intranet, as well as the
uploading of logs and other data.
The GEMC-NL-MOD includes a small transient protection de-
vice (named the NL-ULBD) inside its enclosure. In addition,
the GEMC-NL-MOD is one part of a larger system which in-
cludes a software package to allow its configuration before
use (the NL-MODCONFIG) and a rack-mountable Receiver
(the NL-RCV-RMPCUL) to allow the receipt of alarms, status
and supervisory data. A short description of each is provided
below:
NL-MODCONFIG Software (version 2.0 or greater):
NL-MODCONFIG is a software program allowing the con-
figuration of the GEMC-NL-MOD with appropriate informa-
tion (such as the static IP address of the module, static IP
address of the NL-RCV-RMPCUL Receiver, etc.). The NL-
MODCONFIG software is run on a PC (see System Re-
quirements) and connects to the GEMC-NL-MOD via its
network connection. In addition, NL-MODCONFIG allows
the updating of the GEMC-NL-MOD firmware. Note: The
NL-MODCONFIG software and its database should be re-
tained if future access is necessary. For more information,
see WI1243.
Central Station Receiver (NL-RCV-RMPCUL)
The NAPCO Net.Link™ NL-RCV-RMPCUL (Receiver) is a
fully UL compliant central station receiver platform. This
Receiver is rack-mountable in a standard 4U configuration.
The NL-RCV-RMPCUL (Receiver) can supervise each
GEMC-NL-MOD, receive alarms, provide a means of
maintaining accounts and provide a means of displaying
alarms and event history (opening/closing, etc.). For more
information, see the NL-RCV-RMPCUL Installation and
programming manual, WI1491.
Transient Protection (NL-ULBD)
The GEMC-NL-MOD includes electromagnetic protection
and meets direct and indirect ESD requirements for Infor-
mation Technology Equipment (ITE), however, burglary
applications may call for better protection.
The NL-ULBD is a small device which gives added tran-
sient protection and mounts entirely inside the GEMC-NL-
NAPCO GEMC-NL-MOD
Network Communication Module
INSTALLATION INSTRUCTIONS
MOD housing. The NL-ULBD protects the GEMC-NL-
MOD from significantly larger transients and surges which
may emanate from the network cable or associated de-
vices. It is connected in series between the Ethernet cable
that provides network access and the RJ45 connector in
the GEMC-NL-MOD. The NL-ULBD is required for UL
compliant installations.
SPECIFICATIONS
Electrical Ratings
Input Power: Nominal 12VDC, 85mA.
Note:
Series motherboard AUX PWR terminals. Available
panel 12V combined auxiliary current is reduced by
85mA.
Output Power: PGM-style open collector (negative
trigger) with a maximum sink current of 50mA. Wire
only to power-limited circuits less than 14VDC.
Dimensions: 1½" x 7" x 4¾" (H x W x D)
MAXIMUM WIRE LENGTH
The GEMC-NL-MOD must be mounted inside the NAPCO
Gemini GEMC-Series control panel enclosure. For Fire Alarm
control panels, the GEMC-NL-MOD must be installed inside a
separate UL 864 Listed enclosure. In addition, no more than
20 feet of conduit can be used if connected to a fire alarm con-
trol panel. NOTE: For a UL Supplemental Listing, the wire
length (GEMC-NL-MOD to control panel) must be no more
than 20 feet and the panel shall reside in the same room as
the GEMC-NL-MOD with no intervening walls or barriers.
NOTE: For best results when making RJ-45 cable assem-
blies, it is recommended to use an AMP Brand Professional
crimping tool (part # 3-231652-0), and to always match the
type of cable used (stranded or solid) with the correct type of
RJ-45 plug.
SYSTEM REQUIREMENTS
System Hardware:
NL-MODCONFIG Software:
NL-RCV-RMPCUL Rack-Mount Receiver or NL-CSRCV
Software (software not for UL installations):
12V power must be supplied from GEMC-
Compatible Gemini C-Series Control Panel.
W1077 harness (see wiring diagram).
Access to the local area network.
®
Windows
XP Professional or Windows
®
(Windows
XP Home Edition is not supported).
See WI1491 for the NL-RCV-RMPCUL installation and
programming instructions.
WI1754 08/10
®
2000.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the GEMC-NL-MOD and is the answer not in the manual?

Questions and answers

Summary of Contents for NAPCO GEMC-NL-MOD

  • Page 1 (named the NL-ULBD) inside its enclosure. In addition, trigger) with a maximum sink current of 50mA. Wire the GEMC-NL-MOD is one part of a larger system which in- only to power-limited circuits less than 14VDC. cludes a software package to allow its configuration before Dimensions: 1½"...
  • Page 2: Installation Instructions

    This enables the panel to wait for a transmission ac- Windows Quickloader download software can be used knowledgment from the NL-RCV-RMPCUL Re- to configure the panel to recognize the GEMC-NL-MOD. ceiver. (If the acknowledgment fails to occur within Alternatively, the keypad can be used with Direct Ad- the allotted time, that control panel will generate a dress Program Mode to program the panel.
  • Page 3 1 (+) of the GEMC-NL-MOD. See wir- ing diagram. 7. Power Up GEMC-NL-MOD. Upon applying power, the DS1 LED on the GEMC-NL-MOD will turn on and re- main on during the GEMC-NL-MOD startup sequence (duration is approximately 15 seconds). The LED will...
  • Page 4 "Defaulting" the GEMC-NL-MOD will return it to 4. Power Up GEMC-NL-MOD. Upon applying power, the its original "out of box" condition. Default the DS1 LED on the GEMC-NL-MOD will turn on and re- GEMC-NL-MOD as follows: main on during the GEMC-NL-MOD startup sequence 1.
  • Page 5 ration. The LED will then flash continuously indicating Note: The cable modem at the premises requires standby power, therefore a UL 1481 Listed UPS must be used at the unit has not been programmed. Note: Once the the premises to power the modem. In addition, the installa- unit has been programmed with an acceptable program, tion must meet the requirements of NFPA 72.
  • Page 6: Input Setup

    2.2K Status Type (–) Select the status category to be assigned to the zone when the GEMC-NL-MOD reports a status to the Re- Active high Example: N/O Relay Contact ceiver. The Receiver Service Application Panel Status • screen displays the attribute selected here, including If EOLR is selected from the drop-down list, this en- Check-In Status.
  • Page 7 GEMC-NL-MOD Configuration Overview Windows RJ-45 Control Panel PCD-Windows Quickloader Download Software Wide Area Network GEMC-NL- RJ-45 RJ-45 NL-RCV-RMPCUL Rack Mounted (UL Listed for Commercial Fire and Burglary) (See next page for Central Station Receiver connections for each control panel) All modems, switches and routers shall...
  • Page 8 Detailed GEMC-NL-MOD Connections Control Panel Gemini C-Series Red Flying Lead (12V) Terminal 1 +12V Terminal 2 GND Terminal 3 DATA Terminal 4 BELL Terminal 5 IN0 Terminal 6 IN1 User Defined Terminal 7 IN2 Inputs Terminal 8 IN3 Terminal 9 SUPV.
  • Page 9 RJ25 into the C-Series control panel socket "RJ25 #1" or "RJ25 #2" GEMC-NL-MOD Wiring Diagram Notes: 1. See table below for description of right and left Ethernet Connection LED Functions. 2. Normal operation requires this shunt connector to be placed on top of JP2.
  • Page 10 NOTES...
  • Page 11 NOTES...
  • Page 12: Napco Limited Warranty

    NAPCO. After repair or replacement, NAPCO NAPCO is not an insurer of either the property or safety of the user's assumes the cost of returning products under warranty. NAPCO shall...