Download Print this page

Frico Thermozone SF E Series Original Instructions Manual page 12

Advertisement

Available languages

Available languages

not being used for extended periods of time.
Safety
• For all installations of electrically heated
products should a residual current circuit
breaker 300 mA for fire protection be used.
• Keep the areas around the air intake
and exhaust grilles free from possible
obstructions!
• During operation the surfaces of the unit
are hot!
• The unit must not be fully or partially
covered with textiles, or similar materials,
as overheating can result in a fire risk!
• This appliance is not intended for use by
persons (including children) with reduced
physical or mental capabilities, or lack
of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by
a person responsible for their safety.
Children should be supervised to ensure
that they do not play with the appliance.
Technical specifications |
Type
SF18E09
(SF1-2200E12)
SF24E12 (or SF2-2200E12)
SF36E18 (or SF3-2200E18)
SF54E30
*1) Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m2.
*2) ∆t = temperature rise of passing air at maximum heat output and highest airflow.
*3) Extension possible up to 3900 mm (extension without fans).
Thermozone SF E
Output
Airflow
Sound
stages
level*
[kW]
[m
/h]
[dB(A)]
3
0/6/90/6/9
1800
55
0/9/12
1800
55
0/8/12
2400
56
0/12/18
3600
57
0/20/30
5400
57
SF E
∆t*
Voltage [V]
2
Amperage [A]
1
[°C]
(control)
15
230V~/2,52A
15
230V~/2,52A
15
230V~/3,36A
15
230V~/4,48A
17
230V~/6,72A
Voltage [V]
Length
Amperage [A]
(heat)
[mm]
400V3~/13A
2200
*3
400V3~/17 ,5A
2200
*3
400V3~/17 ,5A
2200
*3
400V3~/26A
2200
*3
400V3~/43,5A
2200
*3
GB
Weight
[kg]
110
110
116
122
110
11