2.2.2
The following installation steps apply for rinse pump:
 Install the outlet tubing into the side or bottom of the warewasher rinse line between the rinse
solenoid valves and the rinse jets.
 Cut a suitable length of outlet tubing and connect between the discharge (right) side of the
Getting Started
rinse pump and the injection fitting;
 Assemble the foot filter to insert in the rinse tank. Insert the outlet poly tube into the flat side of
the stainless steel weight. Push the filter to the bottom, in the same side of the tube. Lock the
tube by pushing the weight to the filter holder and rotating it at the same time, till they are
INSTALLATION
completely facing (Picture 4).
 Cut a suitable length of inlet tubing and connect between the suction (left) side of the pump
and the rinse tank.
 Hand-tighten the compression nuts on both the injection fitting and pump.
Set Up &
Operation
Maintenance &
Accessories
Picture 4*
Troubleshooting
Contacting SEKO
* Installation suggested with plastic T connector
Picture 5
Periodically clean it from possible residues.
TWINDOSE 20
Rinse Plumbing
1/4'' OD poly tube
T connector
Always use the foot filter and make sure that it reaches the bottom of the tank.
Rev. 1.4
non return injection valve
metal band
Stainless steel weight
1/4'' OD PVC tube
Filter
cod. 0000136325
6