Depending on the type of installation, work out the position in which the programmer will be situated remembering
that the site must be:
- indoors (or stored in a waterproof container if installed outdoors)
- a position safe from accidental collision;
- in a position which the technician can easily reach.
Fastening:
• To the wall, distance between centres 75 mm, using two M4 screws and relative rawlplugs (not supplied by us)
• In a waterproof container using the supplied double sided adhesive tape
Interface electrical connection
Warning! The receivers must only be powered by a safety power pack. The use of non safety power
packs could provoke damage to the system.
24V
12V
L1
The interface (printed circuit CS1129A/B) is fitted with an indoor container and has a 12-way terminal board with the
following electrical connection:
12V ac/dc between binding posts 1-2 with jumper "J1" in position "B"
24V ac/dc between binding posts 1-2 with jumper "J1" in position "A"
The interface has four normally open relays which are marked CHA, CHB, CHC, and CHD.
• According to the distance between the interface and the keyboard run the cable carrying the power to the keyboard
and the serial line data.
• Connect the Faston cables: FS1 black to binding post "11"; FS2 red to binding post "12" (fig. 3b)
DC0345
DKS250R
INTERFACE BOX INSTALLATION IP20
J1
P1
PROG
1
2
3
4
5
6
CH A
CH B
OUT
OUT
Description :
Interfaccia
DKS250R
CS1129A DC0345
J2
7
8
9 10 11 12
CH C
CH D
OUT
OUT