MCD500 PCB Replacement
MCD 500 PCB Replacement - Instructions
Overview
This document describes how to replace the LCP (Local Control Panel) and main control PCB in MCD 500 soft
starters (all models).
N.B.!
Many electronic components are sensitive to static electricity. Voltages so low that they cannot be felt,
seen or heard, can reduce the life, affect performance, or completely destroy sensitive electronic
components. When performing service, proper ESD equipment should be used to prevent possible
damage from occurring.
Instructions
Remove all wiring and links from the soft starter before dismantling the unit. Disassemble the unit according
to the instructions below.
After reassembling the unit, apply control voltage and check that the welcome screen displays correctly.
1. Models MCD5-0021B ~ MCD5-0105B
Remove the top cover and terminal blocks from
the starter. Undo the 5 x Torx screws holding the
top plastic in place. Remove the top plastic.
Label each SCR firing loom with the number of the
corresponding phase terminal on the main control
PCB, then unplug the looms. Unplug the
thermistor, fan (on selected models) and CT wires
from the main control PCB. Remove the existing
LCP and main control PCB and replace with the
new LCP/PCB.
Lift off the LCP and main control PCB assembly.
Plug in the looms, replace 5 x Torx screws, top
cover and terminal plugs.
®
MI.17.F1.02 - VLT
is a registered Danfoss trademark
MCD 500 PCB Replacement - Instructions
Page 1/5

Advertisement

loading

Summary of Contents for Danfoss MCD 500 Series

  • Page 1 PCB, then unplug the looms. Unplug the thermistor, fan (on selected models) and CT wires from the main control PCB. Remove the existing LCP and main control PCB and replace with the new LCP/PCB. ® MI.17.F1.02 - VLT is a registered Danfoss trademark Page 1/5...
  • Page 2 Remove 4 x Torx screws from the bypass driver and set aside. PCB, slide out to the right and set aside. Replace the PCBs, plug in the looms, top plastic, top cover and terminal plugs. ® MI.17.F1.02 - VLT is a registered Danfoss trademark Page 2/5...
  • Page 3 PCB assembly. Replace the 7 x Torx screws Replace the header connector. Replace the model board, check that the header connector pins line up with the main control PCB below. ® MI.17.F1.02 - VLT is a registered Danfoss trademark Page 3/5...
  • Page 4 Unplug the thermistor, fan and CT wires from the Undo the 4 x Torx screws from the model PCB LCP and main control PCB assembly. support bracket and set aside. ® MI.17.F1.02 - VLT is a registered Danfoss trademark Page 4/5...
  • Page 5 LCP, top cover and terminal plugs. Take note plastic and replace the top cover and terminal plugs. of the thermistor wiring (grey/red) to the right, and fan wiring (black/red) to the left of the board. ® MI.17.F1.02 - VLT is a registered Danfoss trademark Page 5/5...