Parker QPM3 Installation And Servicing Manual

Parker QPM3 Installation And Servicing Manual

Air oil coolers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
aerospace
climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding
Air Oil Coolers
QPM3 Low pressure pump
Installation and servicing manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QPM3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Parker QPM3

  • Page 1 filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Air Oil Coolers QPM3 Low pressure pump Installation and servicing manual...
  • Page 2 Installation and servicing manual Catalogue HY10-6012-UM/EU Low pressure pump, QPM3 Tillval Accessoires Tillval Accessoires A. Intern bypassventil, 5 eller 10 bar. A. Bypass interne, 5 ou 10 bar. A. I ntern bypassventil, 5 eller 10 bar. A. Bypass interne, 5 ou 10 bar.
  • Page 3: Table Of Contents

    Installation and servicing manual Catalogue HY10-6012-UM/EU Low pressure pump, QPM3 Contents Inledning Säkerhetsföreskrifter Beskrivning Installation Handhavande Förebyggande underhåll Underhåll Tekniska data Försäkran om överensstämmelse Introduction Safety instructions Description Installation Handling Preventive maintenance Maintenance Technical specification Declaration of conformity Einleitung Sicherheitsvorschriften...
  • Page 4: Low Pressure Pump, Qpm3

    Avsedd användning Försiktighet Risk för förgiftning. Oljespill och förbrukad QPM3 lågtryckspump är avsedd för cirkulation av olja i hydraul- olja ska lämnas på därför avsedd depå för att inte orsaka system och växellådor eller påfyllning och avtappning av olja i skada på...
  • Page 5: Installation

    Varning Kläm-/krossrisk. För att undvika personskador vid dräneringspluggarna avlägsnas. lyft är det viktigt att använda rätt lyftmetod. Om QPM3 lågtryckspump installeras i en miljö där vatten kan Kontrollera att den lyftanordning och de lyftdon som används är tränga in i elmotorn, ska en skyddsplåt användas.
  • Page 6: Förebyggande Underhåll

    Beakta elmotorns kapslingsklass. Anm! Vissa elmotorer kan ha en eller flera adapterplattor. Parker ansvarar inte för ingrepp i pumpen vid t.ex. invändig Vid byte av elmotor, skruva ur skruvarna som håller adapterplat- rengöring. Om pumpen har körts med smutsig olja rengörs den torna till elmotorn.
  • Page 7: Tekniska Data

    Installation and servicing manual Catalogue HY10-6012-UM/EU Low pressure pump, QPM3 Teknisk data Tekniska data Motoreffekt Pumpkapacitet Vikt Ljudtrycksnivå LpA l/min dB (A) vid 1 m** QPM3 10 0,25 QPM3 20 0,75 QPM3 30 1,50 QPM3 40 0,75 QPM3 40 1,50...
  • Page 8: Försäkran Om Överensstämmelse

    If the product is not delivered complete by Parker Hannifin Manufacturing Sweden AB the product is also not CE-marked by Parker Hannifin Manufacturing Sweden AB and must not be put into service until the product has been declared in conformity with the requirements of the relevant directives and standards.
  • Page 9: Introduction

    QPM3 low pressure pump into service. Installation and maintenance work should only be carried out by Caution Risk of severe burns. As the pump could qualified personnel.
  • Page 10: Installation

    Precaution Risk of bodily injury. Make sure that all parts of the pump are firmly secured. Prior to initial start-up An upright position of the QPM3 pump, standing on the electric mo- Precaution Make sure that the unit is securely fixed and tor feet is recommended.
  • Page 11: Preventive Maintenance

    Remove the shaft coupling detail from the crankshaft. Parker will not be held responsible for any interference in the Note! Certain motors have one or more adapter plates. To pump such as internal cleaning. If the pump has been run with remove the electric motor, remove the screws fixing the adapter contaminated oil, clean it by running it with clean oil.
  • Page 12: Technical Specification

    100 °C Compatibility Mineral oil Synthetic oils Vegetable oils oljor Turbine oils Contact your local Parker office for operation with other oils or operation under extreme conditions. Material QPM3 low pressure pump Aluminium, steel O-rings and gaskets Nitrile rubber Surface treatment...
  • Page 13: Declaration Of Conformity

    If the product is not delivered complete by Parker Hannifin Manufacturing Sweden AB the product is also not CE-marked by Parker Hannifin Manufacturing Sweden AB and must not be put into service until the product has been declared in conformity with the requirements of the relevant directives and standards.
  • Page 14: Einleitung

    öl sind vorschriftsmäßig zu entsorgen, um Gefahren für Garantie und Reklamationen Menschen, Güter und die Umwelt zu verhindern. Im Fall von Defekten wenden Sie sich bitte an Parker. Werden an Vorsicht Sturzgefahr und Gefahr von Sachschäden. einer QPM3 Niederdruckpumpe eigenmächtig Reparaturen und/ Wird die Pumpe als Leiter benutzt, kann dies zu Stürzen...
  • Page 15: Beschreibung

    Hebetechnik angehoben werden. Kontrollieren Sie, ob alle werden. Hebevorrichtungen und -werkzeuge frei von Mängeln und Wird die QPM3 an einem Ort betrieben, an dem Wasser in den für das Gewicht des Geräts zugelassen sind. Elektromotor eindringen kann, ist ein Schutzschild zu verwenden.
  • Page 16: Vorbeugende Wartung

    • Ventile oder ähnliche Regelungsvorrichtungen offen sind und Schutzklasse des Elektromotors beachten. keine Defekte an Leitungen und Kupplungen vorliegen. Parker haftet nicht für Eingriffe in die Pumpe, z.B. Reinigung des Pumpeninneren. Wurde die Pumpe durch schmutziges Öl Beim Start verunreinigt, kann sie durch einen Durchlauf mit sauberem Öl gesäubert werden.
  • Page 17: Wartung

    Wartung Montage der Pumpe und der Kupplung am Elektromotor Siehe Abb. 5. Parker haftet nicht für die Folgen von Reparaturen oder Umbauten, Gefahr Elektroschock. Der Elektroanschluss darf nur die eigenmächtig vom Kunden vorgenommenen wurden. von einem zugelassenen Elektriker durchgeführt werden! Demontage der Pumpe und der Kupplung vom 1.
  • Page 18: Technische Daten

    Maximaler Betriebsdruck 10 bar Maximal zulässige Öltemperatur 100 °C Kompatibilität Mineralöl Synthetische Öle Pflanzliche Öle Turbinenöle Vor der Verwendung anderer Öle oder bei extremen Betriebsbedingungen Kontakt mit Parker aufnehmen. Werkstoffe Pumpe Aluminium, Stahl O-Ringe und Dichtungen Nitrilgummi Oberflächenbehandlung Eloxierte Flächen Elektromotor 3-phasiger Asynchronmotor gem.
  • Page 19: Konformitätserklärung

    If the product is not delivered complete by Parker Hannifin Manufacturing Sweden AB the product is also not CE-marked by Parker Hannifin Manufacturing Sweden AB and must not be put into service until the product has been declared in conformity with the requirements of the relevant directives and standards.
  • Page 20: Introduction

    Utilisation prévue Avertissement Risque de brûlures graves. Pendant le La pompe à basse pression de type QPM3 est destinée à la fonctionnement, la pompe basse pression peut devenir circulation des huiles dans p.e. des systèmes hydrauliques et très chaude.
  • Page 21: Description

    L’installation dans un endroit inapproprié ou un fonctionnement dans bouchons appropriés. des conditions de travail extrêmes, risque d’entraîner une pression Dans le cas où la pompe QPM3 est installée dans un endroit où acoustique élevée. de l’eau peut entrer dans le moteur électrique, utilisez une tôle protectrice.
  • Page 22: Consignes D'emploi 22 Fr

    Pendant le fonctionnement Avertissement Risque de blessures corporelles et dom- mages aux biens. La pompe QPM3 ne doit pas être utilisée dans des conditions qui pourraient engendrer des niveaux de pressions supérieurs aux pressions admissibles dans la pompe. Ceci peut se produire si le circuit sur le côté sor- tie de la pompe est fermé...
  • Page 23: Entretien

    Entretien Montage de la pompe et du raccord au moteur électrique Voir Figure 5. La responsabilité de Parker concernant le produit cesse dès que Danger Risque d’électrocution. Toute connexion électrique des réparations et/ou des modifications ont été effectuées sur doit être effectuée par un électricien agrée.
  • Page 24: Caractéristiques Techniques

    Température d’huile maxi autorisée 100 °C Compatibilité Huile minérale Huiles synthétiques Huiles végétales Huiles pour turbines Consultez Parker en cas d’utilisation d’autres huiles ou d’une utilisation dans des conditions extrêmes. Matériaux Pompe Aluminium, acier O-Ringe und Dichtungen Acier Oberflächenbehandlung Caoutchouc au Nitrile Revêtement...
  • Page 25: Déclaration De Conformité

    If the product is not delivered complete by Parker Hannifin Manufacturing Sweden AB the product is also not CE-marked by Parker Hannifin Manufacturing Sweden AB and must not be put into service until the product has been declared in conformity with the requirements of the relevant directives and standards.
  • Page 26: Introducción

    Lea detenidamente este manual y los textos de advertencia del manipulación. mismo antes de utilizar la bomba QPM3. Esto le permitirá sacar Advertencia Riesgo de heridas corporales. Asegurarse el máximo provecho a la bomba y evitará un uso incorrecto del de que la bomba esté...
  • Page 27: Descripción

    En caso de una instalación por Utilizar la placa de protección si la bomba QPM3 se instala en un encima del nivel de aceite del depósito, minimizar la diferencia lugar donde el agua puede entrar en el motor eléctrico. La placa de de altura y instalar una válvula de retención o válvula de cierre en...
  • Page 28: Modo De Empleo 28 Es

    Rango de viscosidad recomendado es de 10 – 800 cSt teniendo en cuenta la potencia del motor. Consulte con Parker acerca del uso de aceites de alta viscosidad o sobre cuándo operar en modo de arranque en frío. Para un funciona- miento óptimo, el grado de limpieza del aceite debe ser, según...
  • Page 29: Mantenimiento

    Mantenimiento Montaje de la bomba y del acoplamiento al motor eléctrico Ver fig 5. Parker no se responsabilizará de ninguna reparación o Peligro Riesgo de electrocución. La conexión eléctrica modificación efectuada por el usuario.. debe ser realizada por personal eléctrico cualificado.
  • Page 30: Características Técnicas

    100 °C Compatibilidad de fluido Aceite minerál Aceites sintéticos Aceites vegetales Aceites para turbinas Para utilizar otros aceites, o para el funcionamiento bajo condiciones extremas, contacte con Parker. Material Bomba Aluminio, acero Juntas tóricas y juntas hermeticas Goma nitrilo Revestimiento Anodizado Motor elétrico...
  • Page 31: Declaración De Conformidad

    If the product is not delivered complete by Parker Hannifin Manufacturing Sweden AB the product is also not CE-marked by Parker Hannifin Manufacturing Sweden AB and must not be put into service until the product has been declared in conformity with the requirements of the relevant directives and standards.
  • Page 32 * Certains moteurs sont équipés d'une ou plusieurs plaques * Vissa elmotorer kan ha en eller flera adapterplattor. d'adaptation. Component list Lista de componentes A. QPM3 low pressure pump A. Bomba B. Mounting kit B. Kit de montaje (shaft coupling detail and adapter plate, if any)* (pieza de acoplamiento y placa adaptadora si procede*) C.
  • Page 33 Installation and servicing manual Catalogue HY10-6012-UM/EU Low pressure pump, QPM3 QPM3 LOW PRESSURE PUMPS Order no/pos. Designation Olaer AB Tel:+46 8 636 07 00 Fax:+46 8 767 97 56 www.olaer.se G1½ D-koppling Y-koppling D-connection Y-connection D-Anschluss Y-Anschluss Connexion en D Connexion en Y Conexión en D...
  • Page 34 Installation and servicing manual Catalogue HY10-6012-UM/EU Low pressure pump, QPM3 Parker Hannifin Corporation Hydraulics Group...
  • Page 35 Installation and servicing manual Catalogue HY10-6012-UM/EU Low pressure pump, QPM3 Parker Hannifin Corporation Hydraulics Group...
  • Page 36 ZA – South Africa, Kempton Park Tel: +27 (0)11 961 0700 parker.southafrica@parker.com © 2013 Parker Hannifin Corporation. All rights reserved. Catalogue HY10-6012-UM/EU, 1M, 03/2013, VITT EMEA Product Information Centre Free phone: 00 800 27 27 5374 (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL,...

Table of Contents