7. DISMANTLING AND DISPOSAL

Only trained personnel is allowed to dismantle the pump in accordance with the current regulations in
the country where it is installed.

8. PROBLEMS, CAUSES AND SOLUTIONS

fi«
CAUTION
Before taking any steps, follow the instructions in the "SWITCHING OFF" section. If it is not
possible to restore correct operation of the pump using the information in the table below, contact
a Skilled Technician.
PROBLEM
The pump does not prime
The pump does not reach
maximum pressure.
Irregular pressure and flow
(pulsating)
The pump is noisy
Poor suction of detergent
CAUSE
Air intake
Delivery outlet is closed (with a
high-pressure cleaner,
for example, the cleaner gun is
closed)
The water supply is insufficient
Unsuitable application
(worn nozzle or too large nozzle,
for example)
The application is set for operation
with suction of detergent
(low pressure).
Air intake
The water inlet filter is dirty.
The water supply is insufficient
Pump does not finish priming
Worn application (clogged nozzle,
for example)
Bottlenecks in suction circuit
Temperature of water supply is
too high
The application is not set for
operation with intake of detergent
(low-pressure)
The detergent used is too viscose
SOLUTION
Check for leaks in the suction
circuit
Cancel the outlet pressure (with
a high-pressure cleaner, for
example, by pressing the lever
on the cleaner gun)
Check that the flow of the mains
water supply conforms with
instructions in the "Features and
Technical Specifications" section
Change the application
Change the application for high-
pressure operation
Check for leaks in the suction
circuit
Clean the filter
Check that the flow of the mains
water supply conforms with
instructions in the "Features and
Technical Specifications" section
Prime the pump as instructed in
the "Standard Operation (High
pressure)" section
Change the application
Check suction circuit
Supply the pump with water
below 60°C / 140°F.
Change setting for this type of
operation as instructed in the
operating and maintenance
manual of the machine that
incorporates the pump
Follow instructions on the
detergent's label regarding its
use and dilution.