Znshine Solar ZXP6-TD60-270/P Installation Manual

Double glass

Advertisement

Installation Manual for
Double Glass
June 27,2018

Advertisement

Table of Contents
loading

Summary of Contents for Znshine Solar ZXP6-TD60-270/P

  • Page 1 Installation Manual for Double Glass June 27,2018...
  • Page 2: Table Of Contents

    6.1 Module overview ............................3 6. 2 Material list..............................4 6.3Installation method............................. 5 6. 4 Compatibility of ZNSHINE SOLAR AUSTRALIA PTY LTD. clamp (clamped) with each frame system..6 6. 6 Selection scheme for clamp........................9 7. Module wiring..............................11 8. Tilt angle of module............................11 9.
  • Page 3: Disclaimer

    1.Disclaimer The installation, operation and use of ZX-D60/ ZX-D72 Series module of ZNSHINE SOLAR AUSTRALIA PTY LTD. are not within the control range of our company. For the loss, damage, harm or expense caused by the improper installation, handling, use or maintenance, ZNSHINE SOLAR AUSTRALIA PTY LTD.
  • Page 4: Unpacking And Storage

    It is recommended to record the unique serial number of each module. 5.Environmentalconditionsandsiteselection 5.1 Weather conditions The installation of ZNSHINE SOLAR AUSTRALIA PTY LTD. crystal series modules should be carried out under the following conditions:  Environment temperature: -40 °C to +40°C ...
  • Page 5: Site Selection

    ZNSHINE SOLAR AUSTRALIA PTY LTD. modules. The mechanical load shall be calculated by professional staff for system installation according to the system design. 5.2 Site selection 5.2.1In most use conditions, ZNSHINE SOLAR AUSTRALIA PTY LTD. PV modules should be installed in the position where the sunshine can be absorbed all year round to the greatest extent.
  • Page 6: Material List

    Connect each Joint frame module Material: aluminum alloy6063 Fix the frame on Frame the bracket bracket Material: aluminum alloy 6063 6. 2 Material list The following parts are only suitable for double glass pressing block type installation system Dimension(mm) Item Name Picture Material...
  • Page 7: Installation Method

    Length and width Frame 60×40 Aluminum alloy 6063 bracket 6.3Installation method Please read the full content soft his chapter, and firstly get familiar with the whole process and then start the installation. In addition, please complete all the site preparations before installation. Installation - suitable for double glass pressing block type installation system.
  • Page 8: Compatibility Of Znshine Solar Australia Pty Ltd. Clamp (Clamped) With Each Frame System

    Place the clamp inside the track on the frame. M8SS304 第 Insert the module into the pressing block and install the pressing block, and finally tighten the nuts. M8ss304(16N·m~20N·m) 6. 4 Compatibility of ZNSHINE SOLAR AUSTRALIA PTY LTD. clamp (clamped) with each frame system...
  • Page 9 LTD. clamp is compatible with each frame system or not. Please find the following dimensions before evaluating the frame system. If it is required to change the screw size, please contact ZNSHINE SOLAR AUSTRALIA PTY LTD. (please note that the unit used in the drawings is mm).
  • Page 10 In this case, it is recommended to use the T-type cap. Example B:C-type steel frame installation  ZNSHINE SOLAR AUSTRALIA PTY LTD. recommends using M8 bolt fixing clamp. The tightening torque of M8screw is 16-20N*M.
  • Page 11: Selection Scheme For Clamp

    6. 6 Selection scheme for clamp Mechanical load pressure Clamp length Mounting direction Double Glass +2400*1.5 Pa /- 150mm 1600*1.5Pa *The above distance refers to that from edge of module to center of clamp. +1600*1.5Pa /- 150mm 1600*1.5Pa Double Glass +2400*1.5 Pa /- 150mm 2400*1.5Pa...
  • Page 13: Module Wiring

    8. Tilt angle of module ZNSHINE SOLAR AUSTRALIA PTY LTD. PV modules connected in serial should be installed in accordance with the same orientation and angle. Any different orientations or angles may result in the different amounts of solar radiation received by each module, thus leading to the loss of output power.
  • Page 14: Care And Maintenance

    10. Care and maintenance 10.1 PANEL VISUAL INSPECTION AND REPLACEMENT...
  • Page 15 The modules in a PV array should be regularly checked for damage. Factors such as glass breakage, cable breakage, and junction box damage may lead to function and safety problems. In the case of a damaged module, replace it with the same type of module. Refer to the Product Installation Manual for installation and disassembly of module.
  • Page 16: Specification

    11. Specification 60pcs 156.75×156.75mm Polycrystalline Silicon DOUBLE GLASS Module Module Series 1658*992*6 Dimensions(mm)/ Weight(kg) 1500 Max-System Voltage (VDC) Max-Series Fuse(A) Electrical Performance @ STC ZXP6-TD60-270/P ZXP6-TD60-275/P ZXP6-TD60-280/P Model Type Max-Power Pm(W) 31.3 31.5 31.7 Max-Power Voltage V 8.63 8.74...
  • Page 17: Bypass Diode And Blocking Diode

    PV modules, there by minimizing the heat generation of modules and the current damage of array. At present, ZNSHINE SOLAR AUSTRALIA PTY LTD. PV modules are equipped with bypass diodes in the junction box. Please don't open the junction box to replace the diode, even in case of any fault.
  • Page 18 —The average forward rated current[IF(AV)]is higher than the maximum system current at the highest operating temperature of module. —The peak repetitive reverse voltage [VRRM]is higher than the maximum system voltage at the lowest operating temperature of module.

Table of Contents