Compressor

GATE Indicator
COMP
Lit when a signal lower than the
Enables/disables the compressor.
specified GATE value is being
input.
EDIT
IN Meter
Indicates the status of the input signal.
This is the same as the input level meter
in the preamp.
MIC 1
OUT Meter
Shows the status of the signal that is
MIC 2
output from the compressor.
GR Meter
LINE IN L
Shows the amount of gain reduction
applied by the compressor.
LINE IN R
GATE
Mutes signals below the specified
level. (dB)
THRESH
Specifies the signal level at which
the compressor begins operating.
(dB)
RATIO
ATTACK
Specifies the compression ratio
Specifies the time from when the
at which the audio signal is to be
input level exceeds the threshold
compressed.
until the compressor begins to
operate. (msec)
48V
IN
OUT
SENS
Down
COMP
HPF
sampling
SENS
HPF
COMP
SENS
SENS
KNEE
Adjusts whether the compressor will
start being applied abruptly when
the threshold level is exceeded, or
will change smoothly and gradually
around the threshold level.
6
Input Settings
COMP
Enables/disables the compressor.
PRESET
Select a compressor preset (p. 7).
LINK
If this is on, sensitivity and
compressor settings will be linked
in stereo.
GAIN
Adjusts the output level of the
compressor. (dB)
RELEASE
Specifies the time from when
the input level falls below
the threshold level until the
compressor stops operating.
(msec)