11.- PRELIMINARY NOTES
INSTALLATION .- PRECAUTIONS
The installation and use of this unit must be done by qualified
personnel. The unit has not AC (mains) switch, neither
internal protection fuse. it will be in operation as soon as
power is connected. The installation must incorporate an external mains switch
with a protection fuse in the power line
Power
: 230 Vac
Power
: 115 Vac
Power
: 24 Vdc
Add the appropriate devices to the installation in order to protect the operator
and system when using the unit to control a machine or process where injury
to personnel or damage to equipment may occur as a result of failure of the
unit.
SAFETY PRESCRIPTIONS.- This unit has been designed and
tested under EN-61010-1 rules and is delivered in good condition.
This operator's manual contains useful information for electrical
connections. Do not make wiring signal changes or connections
when power is applied to the unit. Make signal connections before
power is applied and, is reconnection is required, disconnect the AC (mains)
power before such wiring is attempted. Install the unit in a places with a good
ventilation to avoid the excessive heating. And far from electrical noise
source or magnetic field generators such as power relays, electrical motors,
speed controls etc... The unit cannot be installed in open places. Do not use
until the installation is finished.
POWER SUPPLY.- The power supply must be connected to the adequate
terminals (see the connection instructions). The characteristics of the power
supply are showed on the side label. Please make sure that the unit is correctly
connected to a power supply of the correct voltage and frequency. Do not
use other power supply otherwise permanent damage may be caused to the
unit. Do not connect the unit to power sources heavily loaded or to circuits
which power loads in cycle ON-OFF or to circuits which power inductive loads.
WARNING.-
If the power supply is dc voltage, be careful with the polarity
indicated for each terminal.
Manufacturer:
Address:
Products Covered
We declare that the above referrenced instruments comply with the valid rules and regulations detailed below :
REGULATIONS:
EUROPEAN DIRECTIVE FOR LOW VOLTAGE D73/23/CEE AMENDED
BY D93/68/CEE. Equipments powered from 50 to 1000 Vac. and /or from
75 to 1500 Vdc.
EUROPEAN DIRECTIVE FOR THE SAFETY D92/59/CEE.
ELECTROTECHNICAL REGULATION FOR LOW VOLTAGE (RBT) ITC
21, ITC 29, ITC 35. Equipments with power supply lower than 50 Vac
and/or 75 Vdc.
EUROPEAN DIRECTIVE FOR ELECTROMAGNETIC COMPATIBILITY
D89/336/CEE AMENDED BY D93/68/CEE, ACCORDING TO RD1950/
1995 (01/12).
13.- WARRANTY
FEMA ELECTRÓNICA, S.A. warrants this product free of defects in workmanship for ONE (1) year from the date of shipment. This Warranty
is VOID if the unit shows evidence of damages as a result of misapplication, accident, misuse or if the product had been tampered or repaired
by personnel or companies without the official authorization of FEMA ELECTRÓNICA, S.A. This Warranty is VOID also for damages caused by
defective or inappropriate applications. In case of malfunction return the unit to the manufacturer for evaluation. Within the warranty period, and
after examination, and if the unit is found to be deffective and covered by this warranty, the unit will be repaired or replaced.
LIMITATION OF LIABILITY : FEMA ELECTRÓNICA, S.A. shall not be responsible for any damage or loss to other equipment however caused,
which may be experienced as a result of the installation or use of this product. The liability shall not exceed the purchase price paid of the product
upon which liability is based. In no event shall FEMA ELECTRÓNICA, S.A. be liable for consequential, incidental or special damages.
SHIPMENTS FOR REPAIR.- Send free of charges and apropriately packed, to the following address :
FEMA ELECTRÓNICA, S.A.
REPAIRS
Pol.Ind.Santiga (Altimira 14, Talleres 14, Nave 2)
Apartado de Correos 49
E-08210 BARBERÀ DEL VALLÈS (ESPAÑA)
Fuse 50 mA
Fuse 100 mA
Fuse 300 mA

DECLARATION OF CONFORMITY

FEMA ELECTRÓNICA, S.A.
Centro Industrial Santiga
c\ Altimira, 14 (Talleres 14 - Nave 2)
E-08210 - Barberà del Vallès (ESPAÑA)
SERIES : CCT
Francisco Guàrdia
Quality Manager
Barberà del Vallès, 1998
EXCITATION VOLTAGE.- The model CCT-32 supply the Excitation voltage for
sensors, through the terminals 3 & 5. Do not connect these terminals to other
external power supply, permanent damages may result to the unit.
SIGNAL WIRING.- Certain considerations must be given when install the signal
input wires. If the wires are longs can act like an antenna and introduce the
electrical noise to the unit, therefore: Do not install the signal input wires in the
same conduit with power lines, heaters, solenoids, SCR controls etc...and
always far from these elements. When shielded wires are used, leave
unconnected the shield on the transmitter side and connect the other end of the
shield to the ground terminal of the machine.

SAFETY CONSIDERATIONS

PRESCRIPTIONS.- Before starting any operation of adjustment, replace-
ment, maintenance or repair, the unit must be disconnected from any kind of
power supply. Keep the unit clean , to assure good functioning and performance.
To prevent electrical or fire hazard, do not expose the unit to excessive moisture.
or a protection failure can occur, then do not attempt to operate and keep the
unit out of service.
IN CASE OF FIRE
1.- Disconnect the unit from the power supply.
WARNING : In closed areas do not use systems with vaporized liquids.
MODELS : 20, 90, 95
IMMUNITY:
EMISSION:
EN 60204-1 and prEN 60204-1 CHAP. 12, 13Electrical security
prescriptions.
UNE 21352-76: CEI 359-71Operating quality expressions for electronic
equipments.
UNE 20652-80: CEI 284-68Behaviour rules inherent to the handling
of electronic equipments and other similar technics.
INCLUDE THE FOLLOWING INFORMATION.-
Serial Number : ______________________________
Signal Input / Signal Output:____________________
Power Supply : ________________________
Provided by:
____________________________
Description of defective encountered :
Do not operate the unit in the presence of flammable gases
or fumes, such an environment constitutes a definite safety
hazard. The unit is designed to be mounted in a metal panel.
If the unit shows signs of damage, or is not able to show the
expected measures, or has been stored in a bad conditions
2.- Give the alarm according to the local rules.
3.- Switch off all the air conditioning devices.
4.- Attack the fire with carbonic snow, do not use water
in any case.
EN 50082-1 (1992)
CEI 801-2: UNE 20801-2-94 (Nivel 2)
CEI 801-3: UNE 20801-3-94 (Nivel 3)
CEI 801-4: UNE 20801-4-94 (Nivel 3)
UNE 50081-1 (1992)
EN 55022: Clase B/CISPR 22