Genetec Synergis IX SY-SIX-PX8 Installation Manual

Din rail 8 form c relay output expander

Advertisement

Quick Links

Synergis IX DIN Rail 8 Form C Relay
Output Expander
SY-SIX-PX8
Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Synergis IX SY-SIX-PX8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Genetec Synergis IX SY-SIX-PX8

  • Page 1 Synergis IX DIN Rail 8 Form C Relay Output Expander SY-SIX-PX8 Installation Manual...
  • Page 2 In no event shall Genetec be liable to any person or entity with respect to any loss or damage that is incidental to or consequential upon the instructions found in this document or the computer software and hardware products described herein.
  • Page 3: Table Of Contents

    Contents Introduction ..........................5   Installation Requirements ...................... 6   Grounding Requirements ....................... 7   Safety Grounding ............................7   Earth Ground Connection ..........................7   Mounting ..........................9   Removal ............................... 9   Wiring Diagram ............................10   DC Power & Encrypted Module Network ................11  ...
  • Page 4 Mechanical Diagram ......................17   Mechanical Layout ........................ 18   Technical Specifications ...................... 19   New Zealand and Australia ....................20   European Standards ......................21   FCC Compliance Statements ....................23   Industry Canada Statement ....................24   SY-SIX-PX8 | Synergis IX DIN Rail 8 Form C Relay Output Expander | Installation Manual Last Updated July 2018...
  • Page 5: Introduction

    Introduction The Synergis IX DIN Rail 8 Form C Relay Output Expander extends the number of outputs on the system by 8, featuring high current FORM C relays for controlled automation of building systems including lighting and HVAC. Flexible module network architecture allows large numbers of modules to be connected to the RS-485 module network.
  • Page 6: Installation Requirements

    Installation Requirements This equipment is to be installed in accordance with:  The product installation instructions  The National Electrical Code, ANSI/NFPA 70  The Canadian Electrical Code, Part I, CSA C22.1  The Local Authority Having Jurisdiction (AHJ) SY-SIX-PX8 | Synergis IX DIN Rail 8 Form C Relay Output Expander | Installation Manual Last Updated July 2018...
  • Page 7: Grounding Requirements

    Grounding Requirements An effectively grounded product is one that is intentionally connected to earth ground through a ground connection or connections of sufficiently low impedance and having sufficient current-carrying capacity to prevent the build up of voltages which may result in undue hazard to connected equipment or to persons.
  • Page 8 DIN Rail Ground Connections (one or more cabinets installed in the same room) Module Network (RS-485 N+, N-, NA and NB) DIN Rail Enclosure Additional DIN Rail Enclosure (s) PRT-RDM2-DIN Controller Reader Expander Dialer’s Earth Ground Connection PRT-PSU-DIN PRT-PSU-DIN Power Supply Input Expander Output Expander AC Mains Wiring...
  • Page 9: Mounting

    Mounting The Output Expander is designed to mount on standard DIN Rail either in dedicated DIN cabinets or generic DIN Rail mounting strip. When installing the Output Expander ensure that there is adequate clearance around all sides of the device and that air flow to the vents of the unit is not restricted.
  • Page 10: Wiring Diagram

    Wiring Diagram Output Expander System Controller or module supplying power to networked devices Power Supply Power Supply Electric Locking Device White Blue 8 Ohm 30W Next modules Black Siren or 1.1A on network (Typical) CAUTION: INCORRECT WIRING MAY RESULT IN Description DAMAGE TO THE UNIT Green...
  • Page 11: Dc Power & Encrypted Module Network

    DC Power & Encrypted Module Network The Output Expander incorporates encrypted RS-485 communications technology, and both module and network power are supplied by the N+ and N- terminals. Network communications input from the Controller or previous module Connection of the communications and DC supply should be performed according to the diagram shown above.
  • Page 12: Outputs

    Outputs The Output Expander has 8 Programmable Outputs (PGMs). These outputs are used to activate bell sirens, lighting circuits, door locks, relay accessory products and other automation points. Outputs 1 to 8 The 8 Outputs each have a FORM C output relay. The connection example below shows the control of an external LED indicator.
  • Page 13: Address Configuration

    Address Configuration The address of the Output Expander is configured via programming and will require entry of the module serial number. The serial number can be found on the identification sticker on the product. Refer to the Synergis System Controller installation manual for address programming details. SY-SIX-PX8 | Synergis IX DIN Rail 8 Form C Relay Output Expander | Installation Manual Last Updated July 2018...
  • Page 14: Led Indicators

    LED Indicators The Output Expander includes comprehensive diagnostic indicators that can aid the installer in diagnosing faults and conditions. In some cases an indicator may have multiple meanings depending on the status indicator display at the time. Status Indicator The status indicator displays the module status. State Description Fast Flash (green)
  • Page 15: Output Indicators

    Output Indicators The output indicators will show the status of the outputs. State Description Constantly on (red) Output is ON Constantly off Output is OFF SY-SIX-PX8 | Synergis IX DIN Rail 8 Form C Relay Output Expander | Installation Manual Last Updated July 2018...
  • Page 16: Error Code Indication

    Error Code Indication When the module attempts to register or communicate with the system controller a registration error can be generated indicating that it was not successful. Error Code Display The following table is only valid if the FAULT indicator is CONSTANTLY ON and the STATUS indicator is FLASHING RED.
  • Page 17: Mechanical Diagram

    Mechanical Diagram The mechanical diagram shown below outlines the essential details needed to help ensure the correct installation of the Output Expander. 12VDC Pass Through PGM Outputs 5 & 6 PGM Outputs 7 & 8 12VDC Pass Through NC C NO NC C NO V- V+ NC C NO NC C NO V- V+ RELAY 8 RELAY 7...
  • Page 18: Mechanical Layout

    Mechanical Layout The mechanical layout shown below outlines the essential details needed to help ensure the correct installation of the Output Expander. 156.8mm FRONT BACK 143.5m m 156.8m m SY-SIX-PX8 | Synergis IX DIN Rail 8 Form C Relay Output Expander | Installation Manual Last Updated July 2018...
  • Page 19: Technical Specifications

    Genetec continually strives to increase the performance of its products. As a result these specifications may change without notice. We recommend consulting our website (http://www.genetec.com) for the latest documentation and product information.
  • Page 20: New Zealand And Australia

    New Zealand and Australia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards. SY-SIX-PX8 | Synergis IX DIN Rail 8 Form C Relay Output Expander | Installation Manual Last Updated July 2018...
  • Page 21: European Standards

    European Standards CE Statement Conforms to European Union (EU) Low Voltage Directive (LVD) 2014/35/EU, Electro-Magnetic Compatibility (EMC) Directive 2014/30/EU and RoHS Recast (RoHS2) Directive: 2011/65/EU. The CE mark indicates that this product complies with the European requirements for safety, health, environmental and customer protection.
  • Page 22 By design, all Genetec Synergis DIN Rail Enclosures comply with the EN50131 standards. Tamper protection against removal of the cover as well as removal from mounting is provided by tamper switch. Warning: Enclosures supplied by third parties may not be EN50131 compliant and should not be claimed as such.
  • Page 23: Fcc Compliance Statements

    FCC Compliance Statements FCC PART 15, WARNINGS: INFORMATION TO USER This equipment complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 24: Industry Canada Statement

    Industry Canada Statement This class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. CAN ICES-3 (A)/NMB-3(A) SY-SIX-PX8 | Synergis IX DIN Rail 8 Form C Relay Output Expander | Installation Manual Last Updated July 2018...
  • Page 25 © Genetec Inc., 2018. Genetec, Synergis, Synergis IX, the Synergis IX logo and the Genetec Logo are trademarks of Genetec Inc., and may be registered or pending registration in several jurisdictions. Other trademarks used in this document may be trademarks of the manufacturers or vendors of the respective products.

Table of Contents