Synergis IX DIN Rail 2 Door Expander SY-SIX-RDM2-DIN-485 Installation Manual...
Page 2
In no event shall Genetec be liable to any person or entity with respect to any loss or damage that is incidental to or consequential upon the instructions found in this document or the computer software and hardware products described herein.
Introduction The Synergis IX DIN Rail 2 Door Expander With RS485 Enabled Reader Ports extends the number of card reader inputs on the system by 2 or 4 when using multiple reader mode, the number of inputs by 8 (four inputs used for door monitoring and control and up to eight can be used for extended functionality) and the number of outputs by 8 (includes 2 relay lock control outputs).
Installation Requirements This equipment is to be installed in accordance with: The product installation instructions The National Electrical Code, ANSI/NFPA 70 The Canadian Electrical Code, Part I, CSA C22.1 The Local Authority Having Jurisdiction (AHJ) SY-SIX-RDM2-DIN-485 | Synergis IX DIN Rail 2 Door Expander | Installation Manual Last Updated September 2018...
Grounding Requirements An effectively grounded product is one that is intentionally connected to earth ground through a ground connection or connections of sufficiently low impedance and having sufficient current-carrying capacity to prevent elevated voltages which may result in undue hazard to connected equipment or to persons.
Page 8
DIN Rail Ground Connections (one or more cabinets installed in the same room) Module Network (RS-485 N+, N-, NA and NB) DIN Rail Enclosure Additional DIN Rail Enclosure (s) PRT-RDM2-DIN Controller Reader Expander Dialer’s Earth Ground Connection PRT-PSU-DIN PRT-PSU-DIN Power Supply Input Expander Output Expander AC Mains Wiring...
Mounting The Reader Expander is designed to mount on standard DIN Rail either in dedicated DIN cabinets or generic DIN Rail mounting strip. When installing the Reader Expander ensure that there is adequate clearance around all sides of the device and that air flow to the vents of the unit is not restricted.
Wiring Diagram Shield Shield CAUTION: INCORRECT WIRING MAY RESULT IN Black Black Reader (optional extra) DAMAGE TO THE UNIT Green Green White White Brown Brown Orange Orange Blue Blue Reader (optional extra) Yellow Yellow Beeper Outputs Special Function (5 and 8) Function Description 2 Beeps...
DC Power & Encrypted Module Network The Reader Expander incorporates encrypted RS-485 communications technology, and both module and network power are supplied by the N+ and N- terminals. Network communications input from the Controller or previous module Connection of the communications and DC supply should be performed according to the diagram shown above.
Do not connect the shield to any shield used for isolated communication. All Genetec readers are shipped with single LED mode set as default and are fully compatible with the Synergis system, for example the SY-SIX-TSEC-STD-DF-B and SY-SIX-TSEC-EXTRA-DF-KP-B models etc.
Multiple Wiegand Reader Connection When operating in multiple reader mode, the Reader Expander allows the connection of 4 reading devices for entry/exit control of doors per reader input. When connecting Wiegand readers in multiple reader mode the secondary reader that is connected will have all connections wired to the same port as the primary card reader with the DATA 1 connection wired to the opposite reader inputs DATA 1 input.
RS-485 Reader Connection (Entry Only) Applies to RS-485 models only. The following diagram shows the connection of a single RS-485 Reader connected in entry only mode. SHIELD BLACK Shielded Cable GREEN WHITE ORANGE BROWN Shield not Shield is frame connected grounded at BLUE one point...
The exit reader has the green and orange wires connected together. A 330 Ohm EOL (End of Line) resistor MAY be required to be inserted between the NA and NB terminals of the reader and a second 330 Ohm EOL resistor must then be inserted between the source NA and NB terminals at the other end of the wiring.
When connected the REX input can be programmed to operate regardless of the door contact state. The REX input can also be programmed to recycle the door alarm time to prevent nuisance alarms when the door is held open to permit longer entry. Door Lock Connection The Reader Expander provides two lock output relays that can be used to switch electric locks.
Inputs The Reader Expander can monitor the state of up to 8 inputs (or zones) EOL monitored or dry contact devices such as magnetic switches, PIR motion detectors and temperature thermostats. Devices connected to these inputs can be installed to a maximum distance of 300m (1000ft) from the Reader Expander when using 22 AWG wire.
Trouble Inputs Each Reader Expander can monitor up to 16 trouble inputs used to report trouble conditions such as module communications problems. Trouble inputs are used to monitor the status of the Reader Expander and in most cases are not physically connected to an external input. The following table details the trouble inputs that are configured in the system and the trouble type and group that they activate.
Outputs The Reader Expander has 8 Programmable Outputs (PGMs). These outputs are used to activate bell sirens, lighting circuits, door locks, relay accessory products and other automation points. Lock PGM Outputs (1 and 2) Relays are provided on PGM output 1 and 2 these are used for the Lock 1 (PGM1 RD001:01) and Lock2 (PGM2 RD001:02) functions and are used to control electric door strikes and other lock control devices.
Standard PGM Outputs (3 To 8) The PGM outputs 3, 4, 5, 6, 7 and 8 on the Reader Expander are open collector outputs and switch to a ground connection. The PGMs have a default pre-programmed function as detailed in the following table and are used to control the indicator and audible outputs on the attached reading device.
Beeper Outputs Special Functions (5 and 8) The beeper outputs 5 and 8 on the Reader Expander provide special diagnostic information when a card is presented. The following table shows the beeper modes of operation. Function Description 2 Beeps Access Granted. The lock will activate and allow access to the door the card has been presented.
Address Configuration The address of the Reader Expander is configured via programming and will require entry of the module serial number. The serial number can be found on the identification sticker on the product. Refer to the Synergis System Controller installation manual for address programming details. SY-SIX-RDM2-DIN-485 | Synergis IX DIN Rail 2 Door Expander | Installation Manual Last Updated September 2018...
LED Indicators The Reader Expander includes comprehensive diagnostic indicators that can aid the installer in diagnosing faults and conditions. In some cases an indicator may have multiple meanings depending on the status indicator display at the time. Status Indicator The status indicator displays the module status. State Description Fast Flash (green)
Relay Indicators The Relay indicators will show the status of the lock output relay. State Description Constantly on (red) Relay output is ON Constantly off Relay output is OFF Reader 1/Reader 2 Indicators The Reader 1 and Reader 2 indicators display the status of the data being received. State Description Short Flash (red)
Error Code Indication When the module attempts to register or communicate with the system controller a registration error can be generated indicating that it was not successful. Error Code Display The following table is only valid if the FAULT indicator is CONSTANTLY ON and the STATUS indicator is FLASHING RED.
Mechanical Layout The layout shown below outlines the essential details needed to help ensure the correct installation of the Reader Expander. 156.8mm FRONT BACK 143.5m m 156.8m m SY-SIX-RDM2-DIN-485 | Synergis IX DIN Rail 2 Door Expander | Installation Manual Last Updated September 2018...
Technical Specifications The following specifications are important and vital to the correct operation of this product. Failure to adhere to the specifications will result in any warranty or guarantee that was provided becoming null and void. Power Supply DC Input Voltage 11-14VDC DC Output Voltage 10.83-14.0VDC...
Page 29
Genetec continually strives to increase the performance of its products. As a result these specifications may change without notice. We recommend consulting our website (http://www.genetec.com) for the latest documentation and product information.
New Zealand and Australia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards. SY-SIX-RDM2-DIN-485 | Synergis IX DIN Rail 2 Door Expander | Installation Manual Last Updated September 2018...
European Standards CE Statement Conforms to European Union (EU) Low Voltage Directive (LVD) 2014/35/EU, Electro-Magnetic Compatibility (EMC) Directive 2014/30/EU and RoHS Recast (RoHS2) Directive: 2011/65/EU. The CE mark indicates that this product complies with the European requirements for safety, health, environmental and customer protection.
Page 32
By design, all Genetec Synergis DIN Rail Enclosures comply with the EN50131 standards. Tamper protection against removal of the cover as well as removal from mounting is provided by tamper switch. Warning: Enclosures supplied by third parties may not be EN50131 compliant and should not be claimed as such.
FCC Compliance Statements FCC PART 15, WARNINGS: INFORMATION TO USER This equipment complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Industry Canada Statement This class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. CAN ICES-3 (A)/NMB-3(A) SY-SIX-RDM2-DIN-485 | Synergis IX DIN Rail 2 Door Expander | Installation Manual Last Updated September 2018...