Cooper Lighting PORTFOLIO CD61 Series Rough In Installation Instructions page 2

Commercial recessed cfl

Advertisement

PORTFOLIO
INSTALLATION INSTRUCTIONS
IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE
WARNING
!
Risk Of Electrical Shock
Disconnect power at fuse
or circuit breaker before
installing or servicing.
NOTE: This fixture should be supported by main runners or
other structure that is capable of supporting fixture weight of 10 Ibs.
IMPORTANT SAFEGUARDS: When using electrical equipment, basic
safety precautions should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1
This unit is for recessed mounting only. Do not use in
hazardous locations nor near gas or electric heaters.
2
Do not use this equipment for other than the intended use.
3
Install only in accordance with National Electrical Code and local regulatory agencies' requirements.
WARNING:
Installation and servicing to be performed only by qualified personnel, If not qualified, consult an electrician.
To Install Rough-In Section
STEP 1
Install fixture into ceiling cavity using 1/2˝ electrical
conduit. Use 3/4˝ channel, 1-1/2˝ channel,
1/8˝ x 1/2˝ bar stock, or T-bar fasteners as
mounting rails (furnished by others) by inserting
the through hanger brackets at both sides.
STEP 2
Adjust hanger adjustment screws so bottom of
plaster ring is flush with finished ceiling line. Hanger
bracket is reversible for total adjustment of 5˝.
STEP 3
Remove one of the junction box covers. Connect
supply lead wires to lead wires of ballast per wiring
diagram and in accordance with your local
electrical code(s) or N.E.C.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
®
WARNING
!
Risk Of Fire
Do not install insulation
within 3 inches (76 mm) of
any part of the luminaire
fixture or in a way that
may entrap heat.
CD61*/CD62*/CD6S*
Commercial Recessed CFL
Rough-In Installation Instructions
705300-Rev. INS
08/29/2012
CD61*/CD62*/CD6S*
STEP 1-
FIXTURE ATTACHMENT
METHOD
page 1 of 4
Aperture
Ceiling
Cutout
6-3/8˝
7-1/4˝
STEP 3-
JUNCTION BOX COVERS
STEP 2-
HANGER ADJUSTMENT SCREW(S)