Correction of room temperature reading
Carry out the following instructions to correct the room temperature reading between –2°C and + 2°C by steps
of 0.1°C.
1.
Press the button
for 3 seconds
2.
The display shows parameter P1
3.
Press the button
6 times
4.
The display shows parameter P7.
Use the buttons
to adjust the parameter by increments of 0.1°C.
5.
Press any other button to exit the menu.
OTHER FUNCTIONS
Chronothermostat information
1.
Press the button
.
2.
The display shows parameter t1 which indicates the activation time (in minutes) inside the On/Off cycle calculated
by the Chronothermostat.
3.
Press the button
.
4.
The display shows the parameter v which indicates the Chronothermostat software version.
5.
Press any other button to exit the menu.
Room temperature probe fault
In case of a Chronothermostat room temperature probe fault, the display activates fault E92 and the symbol
. Heating is turned off.
Restoring factory settings
Important! With this procedure all the Chronothermostat parameters will be restored to the factory-set value,
except for the time. Therefore it will be necessary to repeat the procedure for the daily automatic programme and
reset the user parameters.
Press the buttons
together for 10 seconds: only the message rE fl ashing is displayed. The procedure is
interrupted on releasing the buttons at any time before the 10 seconds are up. Whereas once reset, the chronother-
mostat activates all the symbols on the display.
INSTALLATION
The Chronothermostat must be fi xed to the wall
at a height of approx. 1.5 m from the fl oor, in a
place away from doors, windows or heat sources
that can affect the room temperature. Disconnect
the power to the boiler before carrying out instal-
lation. Remove the front of the Chronothermostat
by prising with a screwdriver at points A and B.
Then fi x the back of the Chronothermostat to the
wall with the set of screws supplied, making sure
to pass the 2 wires inside the middle hole: remove
the cover protecting the relay contact and make
the electrical connection.
Refi t the front of the Chronothermostat.
TECHNICAL CHARACTERISTICS AND DEFAULT SETTINGS
Setting the time
Operation mode
Heating manual temperature
Room antifreeze temperature
P1
Duration of On/Off cycle
P2
Heating/Cooling control
P3
Pump antiblocking function
P4
Pre-heating function
P5
Maximum number of daily time bands
P6
Temperature measurement unit selection
P7
Correction of room temperature reading
Relay contacts rating
Wiring
Guaranteed average battery life
A
B
12:00
Automatic
20°C
5°C
20 minutes
0=Heating
0=Deactivated
0=Deactivated
6
0=°C
0
24... 230 Vac 5A resistive load
Terminal block for receiving
wires of up to 2.5 mm
1 year
EN

Advertisement

loading

This manual is also suitable for:

Oskar d rfOskar wOskar w rf