Summary of Contents for Omron Focus PM710-M

  • Page 1 Focus TENS Therapy for Knee PM710-M PM710-L Instruction Manual...
  • Page 2: Table Of Contents

    Table of Contents Introduction Safety Instructions ........................2 Intended Use ...........................2 Receiving and Inspection ....................2 Symbols Glossary........................2 Contraindication ........................3 Important Safety Information ..................3 How the Device Works ......................8 1. Know Your Device 1.1 Contents ..........................9 1.2 Part Names and Functions on the Device .............10 2.
  • Page 3: Introduction

    Introduction Thank you for purchasing the OMRON Focus TENS Therapy for Knee. Focus is a wearable, wireless TENS (Transcutaneous Electrical Nerve Stimulation) device that is designed to alleviate chronic, acute and arthritic pain. It delivers TENS technology through simple, convenient control.
  • Page 4: Contraindication

    Contraindication Do not use this device if you have a cardiac pacemaker, implanted defibrillator or other implanted metallic or electronic device. Such use could cause electric shock, burns, electrical interference or death. Important Safety Information Read the Important Safety Information in this instruction manual before using this device.
  • Page 5 Important Safety Information • If your pain does not improve, becomes more than mild, or continues for more than five days, stop using the device and consult with your physician. • DO NOT place this device across your chest or near your heart because the introduction of electrical current into the chest may cause rhythm disturbances to your heart, which could be lethal.
  • Page 6 Important Safety Information • DO NOT place the charger within 6 inches (approx. 15 cm) of any person who is using a pacemaker or implantable cardioverter defibrillator (ICD). The charger emits electromagnetic fields, which may affect pacemakers or ICDs. Battery Handling and Usage •...
  • Page 7 Important Safety Information • Use caution if you have a tendency to bleed internally, such as following an injury or fracture. • Consult with your physician prior to using the device after a recent surgical procedure because stimulation may disrupt the healing process. •...
  • Page 8: Adverse Reactions

    • Ensure that this device has acclimated to room temperature before using. Using this device after an extreme temperature change could lead to improper operation. OMRON recommends waiting for approximately 2 hours for the device to warm up or cool down when the device is used in an environment within the temperature specified as operating conditions after it is stored either at the maximum or at the minimum storage temperature.
  • Page 9: How The Device Works

    How the Device Works The OMRON Focus is a wearable, wireless TENS device that provides relief of chronic, acute* and arthritic pain. Scientific theory suggests that electrical stimulation therapy may work in several ways: 1. The gentle electrical pulses move through the skin to nearby nerves to block or shut out the pain message from reaching the brain from the source of the pain.
  • Page 10: Know Your Device

    1. Know Your Device 1.1 Contents Device Knee Band M/ Knee Band L PM710-M: Knee Band M PM710-L: Knee Band L Soft Case Knee Pad AC Adapter Pad Holder HHP-AM01 Refer to sub-section 4.2 for instructions on how to use. Charger Instruction Manual HV-WCHAA-Z...
  • Page 11: Part Names And Functions On The Device

    1.2 Part Names and Functions on the Device Front Back Lights or flashes according to the battery status. Battery indicator Refer to sub-section 1.2.2. Intensity level Lights or flashes according to the intensity level or indicators situation. Refer to sub-section 1.2.1. Set the intensity level according to your needs.
  • Page 12 1.2 Part Names and Functions on the Device 1.2.1 Intensity Level Indicators Indication Description The power is off. All indicators: off On standby. Press [+] button to start your therapy. All indicators: flash An error has occurred. Contact customer service. Refer to section 9.
  • Page 13: Battery Indicator

    1.2 Part Names and Functions on the Device 1.2.2 Battery Indicator Indication Description Battery is close to low. Charge the battery. Flashes orange Battery is depleted. Charge the battery immediately. Lights orange, then the device turns off The battery is being charged. When it is fully charged, the indicator will go off.
  • Page 14: Preparation

    2. Preparation 2.1 Charging Before using the device, inspect to ensure that: 1. The pad is not damaged. 2. The device is intact. 3. The AC adapter is not broken or damaged. • If you are using the device for the first time or the device has not been used for more than 3 months, charge the battery to full.
  • Page 15: Battery Life

    2.1 Charging Plug the AC adapter into an electrical outlet. Electrical outlet Note • Only use the AC adapter and charger provided with this device for charging. • Make sure not to place this device in a location where it is difficult to plug and unplug the AC adapter.
  • Page 16: Attaching The Device

    2.2 Attaching the Device For first time use, remove the pad from the plastic bag and attach it to the device. Do not remove the plastic film on the back of the pad yet. Note: • To avoid damage, take care not to bend or damage metal connectors.
  • Page 17: Using The Device

    3. Using the Device 3.1 Attaching the Band Below Your Knee Remove the protective sheet from the loop fastener. Remove the plastic films from the pad. For first time use, remove and discard the plastic film from the back of the pad. Sit on a chair and bend your knee 90°.
  • Page 18 3.1 Attaching the Band Below Your Knee Align the device as shown in the following illustration. Place the band on your bare skin directly. Face the side with the indicator lights upward. Make sure the device is on the inside of your knee. If you attach the device on the left knee, align the mark “L”...
  • Page 19 3.1 Attaching the Band Below Your Knee Wrap the band below your knee, then attach the hook and loop fastener so that the band does not slip. Left Knee Placement Right Knee Placement Make sure the band is placed below your knee as shown in the following illustration.
  • Page 20 3.1 Attaching the Band Below Your Knee WARNING • DO NOT use this device during vigorous exercise such as playing sports or climbing. • DO NOT use this device in areas other than below the knee. • Apply the pad ONLY to normal, intact, clean, healthy skin of adult patients. •...
  • Page 21: Get Started With Your Therapy

    3.2 Get Started with Your Therapy Press the power button. 5 intensity level indicators on the left flash white. Press the [+] button. The therapy will start at the lowest intensity level (1) and slowly increase by pressing the [+] button.
  • Page 22 3.2 Get Started with Your Therapy Select intensity level from 1 - 20. Indicators change every 4 intensity levels. Intensity Indicators (blink every 2 seconds) Press the [+] button 5 indicators blink once to increase 1 intensity level. 4 indicators blink 3 indicators blink Press the [-] button once to decrease 1...
  • Page 23 3.2 Get Started with Your Therapy Start your therapy. The session automatically stops after 30 minutes. To stop the session before 30 minutes, press the power button. The device will automatically turn off within 30 minutes when: • The battery is depleted. (The battery indicator will flash orange, then the power immediately turns off.
  • Page 24: Maintenance

    4. Maintenance 4.1 Cleaning 4.1.1 Drying the Pad When the adhesive surface of the pad contains excess fluids such as sweat, dry it by following these instructions. Using the pad without drying it may cause peeling or shifting of the adhesive surface. Turn the device over and dry the adhesive surface of the pad.
  • Page 25: Cleaning The Device

    4.1 Cleaning Place the pad onto the pad holder to allow the adhesive surface to air-dry. • Do not wipe the adhesive surface with tissue or paper-based cloth. holder • If the adhesive surface is too wet, turn it over and let it air dry before placing the pad onto the pad holder.
  • Page 26 4.1 Cleaning 4.1.5 When to replace the pad and band? • Replace the pad after 30 uses. The life of the pad may shorten due to your skin condition or the amount of perspiration that accumulates under the band while wearing it. If the adhesive surface peels off or slides or you feel that the treatment intensity has weakened, replace the pad immediately.
  • Page 27: Storage

    4.2 Storage In between uses, store the pad, band and device on the pad holder in the soft case. To extend the life of the pad, use and store properly. Place the pad onto the pad holder. The pad can be placed onto either side of the pad holder.
  • Page 28: Troubleshooting

    5. Troubleshooting If any of the below problems occur, check to make sure that no other electrical device is within 12 inches (30 cm). If the problem persists, refer to the table below. Problem Possible cause Solution The intensity is The adhesive surfaces of Check placement of the pad.
  • Page 29 5. Troubleshooting Problem Possible cause Solution The device The AC adapter or the Check to ensure that the AC adapter cannot be charger is not connected is properly connected to the charged. properly. charger. Check if the AC adapter is connected to an electrical outlet.
  • Page 30 5. Troubleshooting Problem Possible cause Solution Therapy does The pad is not placed Refer to sub-section 3.1 and place not start. below your knee properly. correctly. The device is not attached Remove the device from the pad, to the pad properly. then attach the device to the pad properly.
  • Page 31: Optional Accessories

    6. Optional Accessories 6.1 Optional Accessories Knee Pad PMKNPAD HV-KNPAD-Z The same Knee Pad is used for either the Knee Band M or the Knee Band L. Knee Band M Knee Band L PMKBAND-M HV-KBAND-MZ PMKBAND-L HV-KBAND-LZ 17.7'' (W) × 2.5'' (H) (450 mm × 64 mm) 20'' (W) ×...
  • Page 32: Optional Accessories - How To Measure For Band Size

    6.2 Optional Accessories - How to Measure for Band Size Measure the circumference of your knee by following the steps below to select the appropriate band size for you. Sit on a chair and bend your knee 90°. 90° Measure the circumference that is Spaced 2 ngers two fingers (middle and forefinger) below your knee with a measuring...
  • Page 33: Specifications

    7. Specifications Product name Focus Model # PM710-M/PM710-L HV-F710-MZ/HV-F710-LZ Power source AC adapter (INPUT AC 100-240 V, 50-60 Hz, 0.12-0.065 A) 1 Lithium-ion battery (3.7 V; Approx. 295 mAh) Rechargeable Will last for 500 uses under the following conditions: new battery, battery fully charged, used 1 time/day in temperatures of 73.4 °F (23 °C) Frequency...
  • Page 34 7. Specifications Number of usable 10 uses (fully charged, 73.4 °F environment, intensity level 10, times per a charge 30 minutes per a use) Durable Period Device: 5 years (Service Life) Knee pad: 30 times (30 minutes/use) Knee band: 6 months Charger: 5 years AC adapter: 5 years Auto Power Off...
  • Page 35: Fcc Statement

    8. FCC Statement FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 and Part 18 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 36: Limited Warranty

    TERMS THAT MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY. OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR DAMAGES.
  • Page 37: Guidance And Manufacturer's Declaration

    10. Guidance and Manufacturer’s Declaration OMRON Focus Information for Accompanying Documents in the Scope of IEC60601-1-2:2014 Important information regarding Electromagnetic Compatibility (EMC) PM710-M and PM710-L conforms to IEC60601-1-2:2014 Electromagnetic Compatibility (EMC) standard. Further documentation in accordance with this EMC standard is available at OmronHealthcare.com/emc.
  • Page 38 OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN Distributed by: OMRON HEALTHCARE, INC. 1925 West Field Court, Lake Forest, IL 60045 U.S.A. OmronHealthcare.com © 2019 OMRON HEALTHCARE, INC. Made in China...
  • Page 40 For questions, call: 1-800-634-4350 3144216-2B...

This manual is also suitable for:

Focus pm710-l

Table of Contents