Maintenance and cleaning

Make sure that the product is disconnected from the mains
before starting any operations.
Note: Open the front door as indicated in fig.15 to access
the filter area.
Filters
Recommended maintenance timetable: In general the level of
air pollution depends on the geographical installation
area, and therefore filter duration is variable. With these
considerations in mind, the maintenance times for filters can
however be set as follows:
Filter inspection: every 50/60 days
Filter replacement: after 3,9 or 12 months (depending on which
was set during installation by the installer). A pre-alarm signal
which warns the user that filter replacement is necessary, will
appear on the display. Filters must be replaced within 2 months
from this signal. The saturated filter alarm will be activated at
the end of this time. The counter will also be reset when an
error is reset (described in the paragraph on "Alarm menu
display").
Note: Failure to clean or replace filters causes serious problems for system efficiency, including:
- Increase in pressure losses in the air circuit and reduction of air flow;
- Consequent decrease in machine yield and worsening of comfort in the environment
Note: Saturated filters are the most common cause of device blocking.