A UT O- OFF SET TI NG

Auto-off function is set to 180 seconds by default.
Auto-off can be set to 60 seconds, 120 seconds, 180 seconds, or disabled
manually.
To change the Auto-off time setting or disable this function:
1. Turn off the scale.
2. Press and hold the ON/OFF button.
3. While holding the ON/OFF button, press the TARE button 4-5 times quickly until
"180" is displayed.
4. Release both buttons.
5. Press the MODE button to switch between "0/60/120/180".
If "0" is selected, the auto-off function will be disabled.
6. After choosing the desired time, press the ON/OFF button again.
7. The display will show "PASS" to confirm this setting.
8. The scale will turn off automatically.
Note:
If "60", "120", or "180" is chosen, the scale will turn off after the designated
number of seconds of inactivity.
If the auto-off function is disabled, the scale will not shut off on its own.
To maintain a longer battery life, turn off the scale by pressing the ON/OFF
button after each use.
C ALIBRAT I ON
1. While the scale is off, press ON/OFF button to turn on the scale.
The LCD display will read "0.0g".
2. Press and hold the MODE button until the display shows "CAL", then release
the button.
3. Press MODE button again and "500g" will flash on the display.
4. Place a 500g calibration weight onto the center of the platform.
5. The LCD will read "PASS" then return to the normal weighing mode.
6. Calibration is complete.