Led Status - Delta SOLIVIA GW Quick Start Instructions

For solivia na, eu or ap inverters

Advertisement

Installation
4
Power
Connection*
*U.S. power receptacle shown.
The SOLIVIA GW comes with an
international AC / DC adapter which
will operate in many countries
worldwide. The input voltage range
must be between 100V - 240V AC.
DB25 to RJ45
Adapter (included
with the gateway)
LED Name(s)
Color and Condition
Power
Green - Solid
10/100 MB LINK
Green - Solid
10/100 ACTIVITY
Green - Flashing Once Per Second
ERROR
OFF
ERROR and RS485 ACTIVE
ERROR Steady Red and RS485 ACTIVE Flashing Green
ERROR and RS485 ACTIVE
ERROR Flashing Red and RS485 ACTIVE Flashing
Green
RS485 ACTIVE
Green - Solid
RS485 ACTIVE
Green - Flashing (every 200 sec.)
RSR85 ACTIVE
OFF
Troubleshooting RS485 communication
1. Try a different Ethernet cable if the network or inverter connection is not established. There may be a broken wire in the cable.
2. Verify that the gateway is powered up - Power LED should appear solid green.
3. If the length of the cable is greater than 65 meters or 200 feet, verify that shielded cable is used.
www.solar-inverter.com
www.deltaenergysystems.com
USA & CANADA
Delta Products Corporation
Support Email:
support.usa@solar-inverter.com
Support Hotline:
1-877-442-4832 or 1-626-369-8019
AUSTRALIA
Delta Energy Systems (Australia) Pty. Ltd.
Support Email:
support.australia@solar-inverter.com
Support Hotline:
61 3 8414 8295
January 30, 2012
To Internet Connected
3
This cable length
should not exceed
100 meters or
300 feet.
Connect the
cable to one
of the connectors
1
2
This cable length
should not exceed
1,000 meters or
3,000 feet.

LED Status

EUROPE
Delta Energy Systems (Germany) GmbH
Support Email:
Support Hotline:
Monday to Friday from 8 am to 5 pm (except official Bank
Holidays) (3.9 ct/min.)
Network Port
RS485 connector in SOLIVIA NA
grid-tie inverter wiring box
at A or B
RS485 connector on SOLIVIA AP
or EU grid-tie inverters
Description
Gateway Powered On
100 Mb Link Established
Data Transfer
Normal Operation (If ERROR LED is lit in combination with a solid or fl ashing
green LED below, there is a problem)
Device Error
• No DHCP response or
• Wrong MAC Address or Inverter ID entered in the confi guration process or
• Confi guration Wizard setup was not completed
Connection to the inverter is successful
Communication with the inverter
No connection to the inverter
support@solar-inverter.com
0180 16 SOLAR (76527)
NOTE: When installing
the monitoring device to a
A
SOLIVIA NA inverter, the
Ethernet cable must be
routed through a 1/2" conduit
on the SOLIVIA NA inverter
wiring box. Please check
the inverter user manual for
further information.
B