Rs485 Lecom-Specific Parameters - Lenze AC Tech SMVector RS-485 LECOM Communication Module Reference Manual

Communications interface
Table of Contents

Advertisement

4.2

RS485 LECOM-Specific Parameters

The parameters listed in Table 6 are only present in the drive if there is an RS485 communication module installed,
P400 = 7 and the module is online (P402 = 3).
Code
No.
Name
P410
Network address
P411
Network
Baud Rate
P420
Network Control
Level
P424
Network Powerup
Start Status
Network Message
P425
time-out
P426
Network Message
time-out action
P427
Valid Network
messages
Received
Communication
P494
Module software
version
Internal Code
P495
Commissioning
Table 6: RS485 LECOM-Specific Parameters
Possible Settings
Default Selection
1
1
0
0
9600 bps
1
4800 bps
2
2400 bps
3
1200 bps
4
19200 bps
0
0
Monitor Only
1
Parameter Programming
2
Programming and Setpoint Control
3
Full Control
4
Full Control (Special)
0
0
Quick Stop
1
Controller Inhibit
50
0
{ms}
0
0
No action
1
Controller Inhibit
2
Quick Stop
3
Trip Fault, F.nF1
0
0
{messages}
CMVLC401A
99
The values 00, 10, 20, 30 ... 90 must not
be used since they are reserved for group
addressing (see section 6.4).
P420 =2, 3: setpoint control using code
number C0046 or C1061.
P420 = 3, 4: drive control using code
numbers C0040 and/or C0135
P420 = 4: setting C0140 = 0 results in
Quick Stop
Stop commands (QUICK STOP, INHIBIT)
will always be accepted.
65000
9999
Read-only
When number of messages exceed
9999, counter resets and resumes
counting from 0.
Read only
Format: x.yz
Read only
Alternating Display: xxx-; -yy
IMPORTANT
9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMVector RS-485 LECOM Communication Module and is the answer not in the manual?

Questions and answers

Related Products for Lenze AC Tech SMVector RS-485 LECOM Communication Module

Table of Contents