FIRMWARE VERSION 1.0
Powerful dry contact relays to control loads up to 15 A and 20 A
Ÿ
Perfect for outdoor lighting, pool pumps, garage door, or gas fireplace
Ÿ
Control up to 3 connected loads independently or together
Ÿ
Z-Wave or optional wall switch control (toggle or momentary type)
Ÿ
Built-in timers for each relay to simplify automation
Ÿ
Remembers and restores on/off status a er power failure
Ÿ
Built-in Z-Wave Plus signal repeater to extend network range
Ÿ
Powered by 12-24 V DC/AC or USB C port for easy set-up
Ÿ
Wall mounting and minimal design for clean installation
Ÿ
S2 security protocol and the latest 500 Z-Wave chip
Ÿ
SPECIFICATIONS
Model Number: ZEN16
Ÿ
Z-Wave Signal Frequency: 908.42 MHz
Ÿ
Power: 12-24 V DC/AC or USB C
Ÿ
Maximum Load: Relay 1: 15A ( HP), R2: 15A ( HP), R3: 20A ( HP)
Ÿ
Range: Up to 100 feet line of sight
Ÿ
Operating Temperature: 32-104° F (0-40° C)
Ÿ
Installation and Use: Indoor only
Ÿ
CAUTION
This is an electrical device - please use caution when installing and
operating the MultiRelay. Remote control of appliances may result in
unintentional or automated activation of power.
BEFORE YOU INSTALL
This device is intended for installation in accordance with
the National Electric Code and local regulations. It is
recommended that a licensed electrician perform this
installation. USE A SINGLE POWER SOURCE AT ALL TIMES.
WIRING: READ IT!
1. CHECK THE LOAD: make sure that the connected appliance does not
exceed 15 A for Relay 1 and Relay 2 or 20 A for Relay 3.
2. POWER OFF: turn the circuit power off in the breaker panel before
you start. If handling wiring from a box with multiple circuits, turn power
off at all of the circuits.
3. REMOVE THE WALL SWITCH: if the load is currently controlled by a
wall switch, carefully remove it from the box and disconnect the wires
from the switch.
4. CONNECT THE MULTIRELAY: follow the instructions in the
appropriate diagram for your set-up. If you can't find your scenario in
the diagrams below, please request custom instructions from our
support team, we're happy to help: ask@getzooz.com
WIRING TIPS
µ
TAKE PICTURES
Before you disconnect any wires, document your set-up and send us
images of your existing installation so we can help if needed.
@
GATHER YOUR TOOLS
Always use the correct screwdriver size for the terminal screws on your
MultiRelay and wall switches (if connecting them). Use appropriate ele-
ctrical tools when cutting, prepping, and stripping electrical wires. If you
don't have the necessary tools to perform the installation or are not
sure which tools to use or how, please hire an electrician to complete
the installation for you.
~
SAFETY FIRST
Follow the National Electrical Code and your local safety regulations
when performing the installation, including (but not limited to), choo-
sing the correct gauge of jumper wires. The recommended gauge for 15
Amp circuits is 14 AWG and 12 AWG for 20 Amp circuits.
MULTIRELAY
ZEN16
FEATURES
PAGE 1
HOW TO SECURE WIRES IN TERMINALS: first, unscrew the appropriate
terminal's screw just far enough so there is a clear opening in the termi-
nal for the wire to go in. Make sure the wire is stripped at the right length
and perfectly straight before you insert it into the terminal. Once you
put the wire in the terminal, carefully screw the terminal screw back in
to hold down the wire. Check the connection by gently pulling on the
connected wire to make sure it's fixed securely.
5. POWER THE MULTIRELAY: connect the USB C power source to the
MultiRelay or use the "+" "-" terminals on the device to bring low voltage
power to it. Never use both at the same time. Make sure you check
polarity on the 12-24 V wires when using DC voltage before connecting
them to the appropriate terminals. In both cases you'll need a standard
1 A power adapter to plug into a standard 120 VAC receptacle.
ZOOZ MULTIRELAY ZEN16 WIRING DIAGRAMS
ZEN16 WIRING DIAGRAM FOR GARAGE DOOR OPENERS
POWER ADAPTER
Sw1
USB C
SWITCH 1 SWITCH 2 SWITCH 3
Connect to simple wall
momentary opener
switches only! "Fancy"
switches with electronic
displays will not work
with the MultiRelay.
ZEN16 WIRING DIAGRAM FOR GAS FIREPLACE MILLIVOLT VALVE
POWER ADAPTER
Sw1
USB C
WALL
SWITCH
ZEN16 WIRING DIAGRAM FOR POOL LIGHT AND POOL PUMP
POWER ADAPTER
12-24 V (DC/AC) POWER INPUT
Sw1
Sw2
USB C
LIGHT
SWITCH
PUMP
SWITCH
12-24 V (DC/AC) POWER INPUT
Sw2
Sw3
+
-
R1
R1 R2
BELL WIRE
OPENER 1
OPENER 2
Use with traditional motorized
garage door openers only. The
MultiRelay will NOT work with
smart openers like the myQ
system.
12-24 V (DC/AC) POWER INPUT
Sw2
Sw3
+
-
R1
R1 R2
+
+
+
GAS FIREPLACE MILLIVOLT VALVE
Sw3
+
-
R1
R1 R2
R2
POOL
LIGHT
POWER SOURCE
PAGE 2
R2
-R3-
OPENER 3
R2
-R3-
-R3-
POOL
PUMP

Advertisement

loading

Summary of Contents for ZooZ ZEN16

  • Page 1 4. CONNECT THE MULTIRELAY: follow the instructions in the appropriate diagram for your set-up. If you can’t find your scenario in ZEN16 WIRING DIAGRAM FOR POOL LIGHT AND POOL PUMP the diagrams below, please request custom instructions from our support team, we’re happy to help: ask@getzooz.com...
  • Page 2 This device requires the following command classes to be supported and recognized by your Z-Wave controller: IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES AND AFFILIATES BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR USE...