DOUBLE RELAY ZEN52 LR
www.getzooz.com
ask@getzooz.com
REGISTER your device for extended warranty and more perks:
www.getzooz.com/register
Manual or Z-Wave on/off control of 2 individual loads up to 5A
Ÿ
Installs behind your existing wall switches (single pole or 3-way)
Ÿ
Small form factor to easily fit in a crowded switch box
Ÿ
NEW: Z-Wave Long Range for a next-level wireless network
Ÿ
Scene control: trigger actions with multi-tap (select hubs only)
Ÿ
Remembers and restores on/off status a er power failure
Ÿ
Built-in Z-Wave timer functionality and signal repeater
Ÿ
Works with LED and incandescent bulbs
Ÿ
700 series Z-Wave and SmartStart S2 Security for a safe network
Ÿ
Model Number: ZEN52 LR
Ÿ
Power: 100-240V~, 50/60Hz
Ÿ
Maximum Load:
150W LED or CFL bulbs
Ÿ
resistive,
HP motors per channel
Range: Up to 300 feet line of sight
Ÿ
Operating Temperature: 32-104° F (0-40° C)
Ÿ
Installation and Use: Indoor only
Ÿ
CAUTION
This is an electrical device - please use caution when installing and
operating the relay. Remote control of appliances may result in
unintentional or automated activation of power.
Do not use this Z-Wave device to control electric heaters or other
appliances which produce the risk of fire, burns, or electrical shock
when unattended.
To reduce risk of overheating and possible damage to other equipment,
do not install this unit to control a receptacle; a motor-operated
appliance; a fluorescent lighting fixture; or a transformer-supplied
fixture.
BEFORE YOU INSTALL
This relay is intended for installation in accordance with the
National Electric Code and local regulations. It is recommen-
ded that a licensed electrician perform this installation.
1. CHECK THE LOAD: don't exceed 150W for LED's, 500W for
incandescent, or 5 A for resistive loads per relay, DO NOT
CONNECT THIS DEVICE TO SWITCHED RECEPTACLES.
2. POWER OFF: turn the circuit power off in the breaker panel
before you start. If installing in a multi-switch box with
multiple circuits, turn power off at all of the circuits.
3. ONE CIRCUIT INSTALLATION: the 2 loads you're planning
to control with your ZEN52 need to be on the same circuit!
4. CHECK THE WIRES: mark load (most o en black), line
(most o en black), neutral (most o en white), and ground
(most o en bare) for each switch. 14 AWG wires only! Don't
rely exclusively on your multimeter to identify the wires!
µ
NOT SURE WHAT YOU'RE SEEING? WE'LL HELP! SUPPORT.GETZOOZ.COM
SEND US PICTURES OF YOUR SET-UP, BEFORE YOU DISCONNECT WIRES.
4. DISCONNECT THE OLD SWITCHES: remove the wires and
label them accordingly.
5. CONNECT THE Z-WAVE RELAY: follow all installation steps
carefully. Wire the relay EXACTLY like in the diagram.
ON/OFF SWITCHES ONLY
Do not connect the Z-Wave relay to a wall dimmer,
illuminated switch, or an electronic add-on switch. The
ZEN51 relay can only be wired with mechanical on/off or
momentary switches in single pole, 3-way, or 4-way settings!
USER MANUAL
FEATURES
SPECIFICATIONS
, 500W incandescent, 5A
WIRING: READ IT!
PAGE 1
ZEN52 WIRING DIAGRAM FOR SINGLE POLE INSTALLATION
1
Keep your existing wall switches connected to ground.
2
Connect the power source to the L black pigtail on the
ZEN52 and the load wires to the OUT1 red and OUT2
blue pigtails for each load. Load and line CAN'T be
swapped so make sure you identified them correctly!
3
Connect the N white pigtail to the bundle of neutral
wires.
4
Connect the wall switch terminals to the S1 yellow and
S2 brown pigtails on the ZEN52 and to the power source
for each switch respectively .
NEED MORE DIAGRAMS?
Scan the QR code for 3-way wiring
diagrams and more installation tips.
QUESTIONS?
ask@getzooz.com
COMPLETE INSTALLATION
Secure your Z-Wave relay and the wall switches in the box
with mounting screws, handling the wires with care.
Install the wall plate and restore power to the circuit.
TEST THE RELAY
The LED indicator should start blinking green when you turn
the power back on. Toggle the switch connected to each
relay to check if the load changes state. If the test fails,
please check that:
power is fully restored to the circuit
Ÿ
wiring matches the instructions exactly
Ÿ
the load isn't too large and overheating the relay causing it
Ÿ
to shut off.
This product should be installed indoors upon completion of
Ÿ
any building renovations.
Prior to installation, the device should be stored in a dry, dust-
Ÿ
and-mold-proof place.
Do not install the relay in a place with direct sun exposure, high
Ÿ
temperature, or humidity.
Keep away from chemicals, water, and dust.
Ÿ
Ensure the device is never close to any heat source or open
Ÿ
flame to prevent fire.
Ensure the device is connected to an electric power source that
Ÿ
does not exceed the maximum load power.
No part of the device may be replaced or repaired by the user.
Ÿ
WARNING
PAGE 2

Advertisement

loading

Summary of Contents for ZooZ ZEN52 LR

  • Page 1 USER MANUAL ZEN52 WIRING DIAGRAM FOR SINGLE POLE INSTALLATION DOUBLE RELAY ZEN52 LR Keep your existing wall switches connected to ground. Connect the power source to the L black pigtail on the ZEN52 and the load wires to the OUT1 red and OUT2 www.getzooz.com...
  • Page 2 ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF PRODUCTS SHALL BE DEEMED 4. Your hub will confirm exclusion, the LED indicator on the WAIVED UNLESS MADE IN WRITING WITHIN THIRTY (30) DAYS FROM ZOOZ'S DELIVERY, OR THE DATE FIXED FOR DELI-VERY IN THE EVENT OF NONDELIVERY.