Pulsar INTE Instruction

Interface ethernet
Hide thumbs Also See for INTE:

Advertisement

Quick Links

Interface
ETHERNET
v.1.0
INTE
CODE:
EN*
Edition: 3 from 05.12.2013
Supercedes edition: 2 from 19.12.2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INTE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pulsar INTE

  • Page 1 Interface ETHERNET v.1.0 INTE CODE: Edition: 3 from 05.12.2013 Supercedes edition: 2 from 19.12.2012...
  • Page 2: Table Of Contents

    INTE TABLE OF CONTENTS 1. General description........................... 3 2. Components arrangement........................3 3. Installation..............................4 4. Ethernet interface configuration......................5 The factory settings of the interface............................5 Introductory information.................................5 STEP 1 - Restoring the factory settings..........................5 STEP 2 – The IP address configuration..........................6 STEP 3 –...
  • Page 3: General Description

    INTE Features:  connection to the ETHERNET network via the RJ45 connector  compliance with the IEEE 802.3 standard 10/100BaseT physical layer  transmission speed 10/100Mbps (auto-sensing)  full-duplex or half-duplex operation (auto-sensing)   built-in web server for configuration data encryption: DES, 3DES, AES ...
  • Page 4: Installation

    INTE 3. Installation. The Ethernet interface should be mounted inside the enclosure of the PSU. The connection between the power supply with Ethernet interface and the router should be made with a twisted pair with RJ45 connectors. The role of the access point controlling the data flow is done by a router connected to a PC via Ethernet cable.
  • Page 5: Ethernet Interface Configuration

    INTE 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root Password - dbps IP address assigned automatically from the routers DHCP server Network name (SSID) No name Network security No security settings...
  • Page 6: Step 2 - The Ip Address Configuration

    INTE After restoring the factory settings of the router and the interface, the yellow LED of the interface is on and the green LED is blinking, indicating active connection. If not, disconnecting and reconnecting the power supply of the module might be necessary. If that does not help, restore the factory settings of the router and the interface once again.
  • Page 7: Step 3 - Setting The Serial Port Parameters

    INTE Fig. 5. The window of network settings. In the settings window, select the „Manually configure network settings” option and change the IP address of the interface in the unblocked area to 192.168.1.101. The subnet mask and the default gateway IP address should be left unchanged.
  • Page 8 INTE Fig. 6. The login window of the Ethernet interface. Type: Username: root Password: dbps Confirm by pressing the „Login” button. The adjustment window will be displayed. Select the „Serial Ports” option from the „Configuration” menu on the left side of the window.
  • Page 9 INTE Fig. 8. The interface configuration panel – serial port parameters. After reloading the page, select the „Basic Serial Settings” tab at the bottom. and enter the same settings as in the picture below. The power supplies of the EN54 series allow higher transmission speed, and therefore...
  • Page 10 INTE Fig. 9. The communication parameters of the serial port. Confirm by pressing the „Apply” button. Next, choose the „Advanced Serial Settings” bar in the lower part of the window and enter the settings in the „TCP Settings” section as shown below. Confirm by pressing the „Apply” button.
  • Page 11: Psu Configuration

    INTE The connection between the Ethernet interface and the power supply requires checking whether the serial port communication parameters are the same. 5. PSU configuration 5.1 Configuration of power supplies of PSBEN series with LCD display. The PSU is fitted with LCD display, which enables setting the communication parameters of the serial port from the LCD panel.
  • Page 12: Configuration Of Power Supplies Of Psben Series With Led Display

    INTE 5.2 Configuration of power supplies of PSBEN series with LED display The PSU is fitted with LED display, which enables setting the communication parameters of the serial port from the LED panel. To enter the setup mode, simultaneously press the „<,>” rightmost and leftmost buttons on the LED panel.
  • Page 13: Configuration Of Power Supplies Of En54 Series With Lcd Display

    INTE 5.3 Configuration of power supplies of EN54 series with LCD display The power supplies of the EN54 series allow higher transmission speed, and therefore instead of 19.2k 8E1 it can be set to 115.2k 8E1. The changed values apply to all settings The PSU is fitted with LCD display, which enables setting the communication parameters of the serial port from the LCD panel.
  • Page 14: Configuration Of Power Supplies Of En54 Series With Led Display

    INTE 5.4 Configuration of power supplies of EN54 series with LED display The PSU is fitted with LED display, which enables setting the communication parameters of the serial port from the LED panel. To enter the setup mode, simultaneously press the „<,>” rightmost and leftmost buttons on the LED panel.
  • Page 15: Setting The Parity Of The Transmission

    INTE 5.4.2 Setting the parity of the transmission - simultaneously press the „<,>” rightmost and leftmost buttons - The „tSt” parameter will be displayed - use the „<” or „>” buttons in order to display the „trP” parameter - press „OK”...
  • Page 16: Configuring The Connection In Powersecurity Program

    INTE 6. Configuring the connection in PowerSecurity program. For further configuration, the PowerSecurity program is required. The program is available on: http://www.pulsar.pl/pl/pliki/PowerSecurity.exe It is an executable file, which does not require installation. 1) Run the PowerSecurity.exe. 2) Choose the Power Supplies > New Power Supply option from the menu bar. The “Configuration of connection”...
  • Page 17: Technical Parameters

    INTE 3) Once the connection configuration is loaded, the window with a „preview” tab is displayed. Press icon in the in the upper left corner to connect with the PSU. As a result, the window will display current parameters of the PSU, automatically updated on the basis of a preset refresh cycle.
  • Page 18 INTE...
  • Page 19 INTE...
  • Page 20 Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. WARRANTY Pulsar K.Bogusz Sp.j. 5 years from the production date. Siedlec 150, 32-744 Łapczyca, Poland WARRANTY IS VALID only upon presentation of the original Phone (+48) 14-610-19-40, Fax.

Table of Contents