aquilar AquiTron AT-APA Installation Instructions Manual

Addressable pinpoint alarm

Advertisement

Quick Links

I N S TA L L AT I O N
I N S T R U C T I O N S
AquiTron
AT-APA
Addressable Pinpoint Alarm

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AquiTron AT-APA and is the answer not in the manual?

Questions and answers

Summary of Contents for aquilar AquiTron AT-APA

  • Page 1 AquiTron AT-APA Addressable Pinpoint Alarm I N S TA L L AT I O N I N S T R U C T I O N S...
  • Page 2 Works with all TraceTek leak detection cables LVD: 60950:2001 +A11:2004 (see technical datasheets)(TT1000, TT1100, EMC: Emission: EN61000-6-3 TT3000, TT5000, TT5001, TT7000) Immunity: EN61000-6-1 :2001 Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 3 • All data and alarms can be continuously consulted via the LAN. • Accurate indication of the location of the leak. • Automatic alarm alert via relay, SNMP trap and alarm email. Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 4: Table Of Contents

    Configuration of optional ambient sensor Page 11 8.0 Modbus TCP/IP registers Page 11 Setting the IP address in a laptop or desktop Page 12 (Windows Management System) 10.0 Guarantee Page 14 Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 5: Installing And Connecting The Alarm Module

    Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 6: Detailed Configuration Of The Module Using The Integrated Web Server

    • RG resistance loop: this is the measured resistance value in ohms of the Red-Green detection circuit. • Alarm timestamp: this is the time when an alarm was activated. Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 7 • A PDF diagram of the leak detection area can be loaded into the LDM for each circuit. Click the “Show Diagram” button to view each circuit. Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 8: Alarm On A Leak Detection Cable

    Buzzer” on the touchscreen. This buzzer can also be stopped remotely via the web application using a computer or tablet with access to the network. ALARM HISTORY All alarms activated in the AT-APA are stored in the memory, together with a timestamp. These events can be consulted at any time, and can also be downloaded to a CSV file. The last 15 alarms are always displayed. Select the date range to retrieve and download older events. Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 9: Configuration

    Select the box. A keyboard appears on the touchscreen. Enter this password, and the home page appears. You will now be able to enter the configuration page. Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 10 Warning: Please keep the new password in a safe location. If the password is changed then lost you will not be able to access the configuration area of your panel without returning it to Aquilar for a factory reset. This will result in all settings, including history, being lost.
  • Page 11: Configuration Of Circuit 1, 2, 3 Or

    ‘sensing’ length of 100m is not exceeded with the combination of cable and weighted lengths. Alarm action definition: select the additional action to be activated in the event of a specific alarm. Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 12: Configuration Of Optional Ambient Sensor

    Leak detection cable status (0=Normal, 1 = Service, 2 = Leak, 3 = Cable fault) Register 30010 Circuit 2 Leak location in metres Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 13: Setting The Ip Address In A Laptop Or Desktop

    Use a network cable to connect the computer or laptop with the AT-APA. Open ‘Settings’ then ‘Network Centre/Adaptor Settings’ to change the IP address of the computer. Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 14 Once you have the panels IP address via either method you will be able to log onto the panel using a standard browser window, where real time status information will be shown and configuration changes can be made. Unit 30, Lawson Hunt Industrial Park, Broadbridge Heath, Horsham, West Sussex, RH12 3JR +44 (0) 1403 216100 info@aquilar.co.uk www.aquilar.co.uk...
  • Page 15: Guarantee

    The only obligations of Aquilar Limited are those in the Aquilar Standard Terms and Conditions of Sale for this product, and in no case will Aquilar Limited be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use or misuse of the product.

Table of Contents