Installation
3. 1 Installatıon Instructıons
Some installation systems require the opening
and removal of the metal grille panel.
3.1.1 Instructions for opening
and removing the metal grille
panel
To open the grille panel, press inwardly on the two
slider catches at each side of the grille panel and
the grille will pivot down.
To remove the metal grille, pull forward on the
right hand side so that the hinge pin on the back
of the grille will be released from the slot in the
side of the casing.
3.1.2 Wall cabinet fixing
• Predrilled wall cabinet: fix the hood onto the
wall cabinet base panel using the four screws
4.2 x 45 mm (supplied with the fixing kit). It is
not necessary to open the metal grille.
• No predrilled wall cabinet:
- If the hood is provided with a paper fixing
template, follow the instructions.
- If the hood is not provided with a paper fixing
template, position the hood on the wall
cabinet base panel and pilot drill the 3.5 x 16
mm screws (not supplied with the fixing kit)
from the inside onto the wood.
3.1.3 Wall mounting
• Drill two Ø 8 mm holes on the wall using the
paper template, insert two rawl plugs and two
4.2 x 44,4 mm screws leaving 5 mm untight-
ened. Open the metal grille panel, hook the
hood on and fully tighten the screws.
• If the hood is not provided with a paper fixing
template, drill two Ø 8 mm holes (see draw.),
insert the plugs and screws, proceeding as di-
rected under paragraph a.
• For wall mounting using wallbrackets (optional),
follow the instructions of the fixing template.
• Pay attention to the safety regulation of point
1.6.
Hood / User Manual
3.1.4 Choice of operating mode
• Evacuation mode
To check that the hood is set up for evacuation,
open the grille panel and make sure that the
conversion lever or the change-over knob on
the centrifugal unit is in the DUCTING position.
The charcoal filter is not required. For ducting to
the outside, the hood is supplied with a rear and
top outlet. A flange spigot of 100 mm diameter
(120 mm in certain models) is usually fitted on
the top outlet and a blanking plug on the rear
outlet. If you choose to duct the hood from the
rear of the casing, you should invert the posi-
tion of the flange and of the blanking plug. Pay
attention to the safety regulation 1.1.
• Internal recirculation mode
To check that the hood is set up for recycling,
open the grille panel and make sure that the
conversion lever or the change-over knob on
the centrifugal unit is in the RECYCLING posi-
tion. The charcoal filter is to be fitted. To fit the
charcoal filter, support the filter with one hand
and turn the thumb screw through the centre of
the charcoal filter. If the filter is of the interlock-
ing type, turn the filter clockwise. The hood can
remain connected to the outside.
3.1.5 Electrical connection and
working test
• The safety measures 1.2, 1.3, 1.4 and 1.5 of para-
graph 1 are to be strictly observed.
• Once the electrical connection has been com-
pleted, check that the worktop illumination,
motor and speeds work properly.