Use

2
The hood is designed to be used either for
exhausting or filter version.

2.1 Ducting version

The hood is equipped with a top air outlet B for
discharge of fumes to the outside (exhaust pipe
and pipe fixing clamps not provided). Connect
the hood and discharge holes on the walls with a
diameter equivalent to the air outlet (connection
flange). Using the tubes and discharge holes
on walls with smaller dimensions will cause a
diminution of the suction performance and a
drastic increase in noise. Any responsibility in the
matter is therefore declined.
A
Attention! If the hood is supplied
with carbon lter, then it must be re-
moved.

Installation

3
Fig. 3
The minimum distance between the supporting
surface for the cooking equipment on the hob and
the lowest part of the range hood must be not less
than 65 cm from electric, gas or mixed cookers. If
the instructions for installation for the hob specify
a greater distance, this must be adhered to.

3.1 Electrical connection

The mains power supply must correspond to the
rating indicated on the plate situated inside the
hood. If provided with a plug connect the hood to a
socket in compliance with current regulations and
positioned in an accessible area, after installation.
10 / EN

2.2 Filter version

In the case of not being able to discharge the
fumes and the steam of cooking outside, the
hood in the lter version can be used mounting the
F deflector on the flue and one or more carbon
filters (on the basis of the model possessed). The
fumes and steam are recycled into the kitchen
through upper grill H.
A
Attention! If the hood is not
supplied with carbon lter, then it
must be ordered and mounted.
The models with no suction motor only operate
in ducting mode, and must be connected to an
external suction device (not supplied).
The connecting instructions are supplied with the
peripheral suction unit.
If it not fitted with a plug (direct mains connection)
or if the plug is not located in an accessible area,
after installation, apply a double pole switch in
accordance with standards which assures the
complete disconnection of the mains under
conditions relating to over-current category III, in
accordance with installation instructions.
Warning! Before re-connecting
A
the hood circuit to the mains supply
and checking the efficient function,
always check that the mains cable is
correctly assembled.
Warning!
A
replacement must be undertaken
by the authorised service assistance
centre or similar qualified person.