KEY 14A Instructions And Warnings For Installation And Use

Modular control unit for one or two 24 vdc motors

Advertisement

Quick Links

Istruzioni ed avvertenze per l'installazione e l'uso
Instructions and warnings for installation and use
Instructions et avertissements pour l'installation et l'usage
Instrucciones y advertencias para su instalación y uso
Anleitungen und Hinweise zu Installation und Einsatz
Instruções e advertências para a instalação e utilização
Centrale modulare per uno o due motori 24 Vdc
Modular control unit for one or two 24 Vdc motors
Logique de commande modulaire pour un ou deux moteurs 24 Vcc
Central modular para uno o dos motores de 24 Vcc
Modulares Steuergerät für einen oder zwei 24-VDC-Motoren
Unidade modular para um ou dois motores 24 Vdc
Centrala modułowa dla jednego lub dwóch silników 24 VDC
Management
System
ISO 9001:2008
www.tuv.com
ID 9105043769
14A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 14A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KEY 14A

  • Page 1 Istruzioni ed avvertenze per l’installazione e l’uso Instructions and warnings for installation and use Instructions et avertissements pour l’installation et l’usage Instrucciones y advertencias para su instalación y uso Anleitungen und Hinweise zu Installation und Einsatz Instruções e advertências para a instalação e utilização Centrale modulare per uno o due motori 24 Vdc Modular control unit for one or two 24 Vdc motors Logique de commande modulaire pour un ou deux moteurs 24 Vcc...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety warnings page 19 Product Introduction page 20 Description of the control unit page 20 Description of the connections page 20 Models and technical characteristics page 20 List of cables required page 21 Preliminary Checks page 21 Installing the Product page 22 Electric connections...
  • Page 3: Safety Warnings

    Read the instructions carefully before proceeding with installation. should this occur, disconnect the power supply immediately and contact a Key Automation Service Centre. Use of the automation The design and manufacture of the devices making up the system in these conditions may cause hazards;...
  • Page 4: Product Introduction

    2 - INTRODUCING THE PRODUCT 2.1 - Description of the control unit The 14A control unit is a modular system for the control of Key the menu structure also allows easy setting of working times and Automation motors for the electric opening and closure of swing and operating modes.
  • Page 5: List Of Cables Required

    1 cable of 4 x 0.5 mm 20 m Sensitive edge 1 cable of 2 x 0.5 mm 20 m Key-operated selector switch 1 cable of 4 x 0.5 mm 20 m Motor power supply line 1 cable of 2 x 1.5 mm...
  • Page 6: Installing The Product

    4 - INSTALLING THE PRODUCT 4.1 - Electrical connections WARNING - Before making the connections, ensure that the control unit is not powered up PO24 CONNECTIONS PO24 POWER MODULE Limit switch 1 input (only for SUN) Limit switch 2 input (only for SUN) Limit switch / encoder power supply positive common (12 Vdc 50 mA MAX) Encoder S signal input...
  • Page 7: Using The Display Programmer

    SCROLL UP prompted to select the language. Press ▲ or ▼ to select the language required and then confirm with V. If no language is selected (X key pressed), the control unit will CANCEL CONFIRM use the default language (ENGLISH) until the next time it is switched on.
  • Page 8: Auto-Learning Of The Travel Stroke

    When prompted, press the V key to set the motor’s deceleration point, following the instructions on the display. It is important to allow for the gate’s moment of inertia and to check that the decelerations set allow the motors to brake the leaves of the gate before they reach the limit position.
  • Page 9: Diagnostic

    4.6 - Diagnostic A number of parameters, including the current absorption or motor speed, can be viewed at any time using this function. Proceed as follows: MOTOR 1 CURRENT (mA) MOTOR 2 CURRENT (mA) MOTOR 1 POSITION (%) MOTOR 2 POSITION (%) DIAGNOSTIC MOTOR 1 SPEED (%) MOTOR 2 SPEED (%)
  • Page 10: Night Lights

    Motor speed during closing deceleration phase. 1 = minimum 2 = low SLOW DOWN 3 = medium CLOSING SPEED 4 = high 5 = maximum SS configuration: 0 = Normal (OP-ST-CL-ST-OP-ST…) 1 = Alternate STOP (OP-ST-CL-OP-ST-CL…) STEP BY STEP 2 = Alternate (OP-CL-OP-CL…) 3 = Apartment block –...
  • Page 11: Testing And Commissioning

    5 - TESTING AND COMMISSIONING THE AUTOMATION SYSTEM The system must be tested by a qualified technician, who must the relevant regulatory requirements, especially the EN12445 perform the tests required by the relevant standards in relation standard which specifies the test methods for gate and door to the risks present, to check that the installation complies with automation systems.
  • Page 12: Details

    6 - FURTHER DETAILS 6.1 - Customising the system - ADVANCED SETTINGS If necessary, users may select the ADVANCED SETTINGS, which CAUTION: the parameters may vary with respect to those in the allow modification of the control unit’s advanced parameters. table below, depending on the motor to be installed.
  • Page 13 0 = off DEAD MAN 1 = on (safety devices disabled) 0 = deactivated GATE OPEN 1 = gate open light ON/OFF INDICATOR 2 = gate open light proportional x 1000 Service interval cycle threshold MAINTENANCE cycles Enabling of continuous flashing when service is required (only active with gate closed).
  • Page 14: Rx4X Receiver

    6.2 - RX4X RECEIVER If necessary, users may select the RX4X RECEIVER MENU, used Proceed as follows: to manage the parameters relating to the radio unit. RX4X Allows a new code to be memorised in the receiver ADD TX DELETE TX Allows deletion of a code from the receiver Clears the receiver’s entire memory DELETE ALL...
  • Page 15: Programmer Flow Chart

    6.3 - Programmer flow chart QUICK PROGRAMMING ▲ ▼ MOTOR 1 CURRENT (mA) FULL PROGRAMMING MOTOR 2 CURRENT (mA) MOTOR 1 POSITION (%) ▲ ▼ MOTOR 2 POSITION (%) DIAGNOSTIC MOTOR 1 SPEED (%) MOTOR 2 SPEED (%) ▲ ▼ TOTAL CYCLES (CYCLES) CYCLES LEFT BEFORE SERVICE SOFTWARE VERSION...
  • Page 16: Instructions And Warnings For The

    In the event of safety devices out of ser- Thank you for choosing Key Automation S.r.l.;...
  • Page 17 NOTES...
  • Page 18 Il sottoscritto Nicola Michelin, Amministratore Delegato dell’azienda The undersigned Nicola Michelin, General Manager of the company Key Automation srl, Via Alessandro Volta, 30 - 30020 Noventa di Piave (VE) – ITALIA dichiara che il prodotto tipo: declares that the product type:...
  • Page 19 Key Automation S.r.l. Via A. Volta 30 - 30020 Noventa di Piave (VE) T. +39 0421.307.456 - F. +39 0421.656.98 Instruction version info@keyautomation.it - www.keyautomation.it 580IS14A rev.04...